HPlogo SNA Link/iX Node Manager's Guide > Chapter 2 SNA Node and Link Configuration

Data Required from the AS/400 Configuration

MPE documents

Complete PDF
Table of Contents
Index

Data in an SNA node configuration file must correspond to information from the remote AS/400 type 2.1 parameters. So, before using NMMGR, you should have certain information from the AS/400 configuration.

The AS/400 information that corresponds to SNA node configuration information for SNA/SDLC links, SNA/X.25 links, and SNA/Token Ring links is described below.

SNA/SDLC Information

For the AS/400 and the HP e3000 to communicate, you must coordinate the SNA/SDLC node configuration with the AS/400 configuration. The HP SNA Products Remote System Configuration Guide explains this configuration.

Table 2-8 "AS/400 Parameter Values for SDLC Link" shows the relationships between parameters from the AS/400 configuration and items in the SNA node configuration file for an SNA/SDLC link. Each NMMGR screen field is described later in this chapter.

Table 2-8 AS/400 Parameter Values for SDLC Link

AS/400 Configuration Parameter

Field in NMMGR Screen

NMMGR Screen Name

MAXFRAME in the line descriptionMAX DATAPU Data
LINESPEED in the line descriptionTransmission SpeedSDLC Link Data
EXCHID in the controller descriptionID BLK combined with ID NUMPU Data
STNADR in the controller descriptionStation IDSDLC Link Data
RMTLOCNAME in the device descriptionLU NameLU Data

SNA/X.25 Information


For the AS/400 and the HP e3000 to communicate, you must coordinate the SNA/X.25 node configuration with the AS/400 configuration. The HP SNA Products Remote System Configuration Guide explains this configuration.

Table 2-9 "AS/400 Parameter Values for X.25 Link" shows the relationships between parameters from the AS/400 configuration and items in the SNA node configuration file for switched virtual circuits (SVCs) of an SNA/X.25 link. Each NMMGR screen field is described later in this chapter.

Table 2-9 AS/400 Parameter Values for X.25 Link

AS/400 Configuration Parameter

Field in NMMGR Screen

NMMGR Screen Name

NETADDR in the line description Remote's X.25 Network AddressX.25 Link Data

SNA/Token Ring Information


For the AS/400 and the HP e3000 to communicate, you must coordinate the SNA/Token Ring node configuration with the AS/400 configuration. The HP SNA Products Remote System Configuration Guide explains this configuration.

Table 2-10 "AS/400 Parameter Values for Token Ring Link" shows the relationships between parameters from the AS/400 configuration and items in the SNA node configuration file for an SNA/Token Ring link. Each NMMGR screen field is described later in this chapter.

Table 2-10 AS/400 Parameter Values for Token Ring Link

AS/400 Configuration Parameter

Field in NMMGR Screen

NMMGR Screen Name

MAXFRAME in the line descriptionMAX DATAPU Data
EXCHID in the controller descriptionID BLK combined with ID NUMPU Data
ADPTADR in the line description for the AS/400 systemRemote Station AddressToken Ring Link Data
SSAP in the controller description for the AS/400 systemRemote DSAPToken Ring Link Data
DSAP in the controller description for the HP e3000Local SSAPToken Ring Link Data
ADPTADR in the controller description for the HP e3000Local Station AddressToken Ring Link Data
RMTCPNAME in the APPC display controller description (APPC only)*Local Control Point NamePU Data
*If APPC is not being configured, HP recommends that you use the PU name in the Local Control Point Name field.




Data Required from the Host Configuration


NMMGR Configuration Overview