Data in an SNA node configuration file must correspond to information from the host configuration. So, before using NMMGR, you should have certain information from the host configuration.

The host information that corresponds to SNA node configuration information for SNA/SDLC links, SNA/X.25 links, and SNA/Token Ring links is described below.

SNA/SDLCMUX Information

For the host and the HP e3000 to communicate, you must coordinate the SNA/SDLCMUX node configuration with the ACF/NCP and ACF/VTAM host configurations. The HP SNA Products Remote System Configuration Guide explains these configurations. Table 2-1 "Host ACF/NCP and ACF/VTAM Values for SDLCMUX" shows the relationships between items from the host configuration and items in the SNA node configuration file for an SNA/SDLCMUX link. Each NMMGR screen field is described later in this chapter.

Table 2-1 Host ACF/NCP and ACF/VTAM Values for SDLCMUX

Host Configuration Macro and Operand

Field in NMMGR Screen

NMMGR Screen

LINE SPEED SpeedLink Data
PU PUNAMESNA Node NameConfiguration
ADDR Station IDLink Data
IDBLK ID BLKPU Data
IDNUM ID NUMPU Data
MAXDATA MAX DATAPU Data
PUTYPE Node TypePU Data
LU LUNAMELU NameLU Data
LOCADDR LU#LU Data

SNA/X.25 Information


For the host and the HP e3000 to communicate, you must coordinate the SNA/X.25 node configuration with the host configuration. The HP SNA Products Remote System Configuration Guide explains this configuration.

Table 2-2 "Host Macro Values for X.25 Link PVC" shows the relationships between items from the host configuration and items in the SNA node configuration file for permanent virtual circuits (PVCs). Each NMMGR screen field is described later in this chapter.

Table 2-2 Host Macro Values for X.25 Link PVC

Host Configuration Macro and Operand

Field in NMMGR Screen

SNA Node NMMGR Screen

X25.LINE TYPEVirtual Circuit TypeX.25 Link Data
X25.PU PUNAMESNA Node NameConfiguration
New NameConfiguration
PUTYPENode TypePU Data
MAXDATAMAX DATAPU Data
X25.LU LUNAMELU NameLU Data
LOCADDRLU#LU Data

Table 2-3 "Host Macro Values for X.25 Link SVC" shows the relationships between items from the host configuration and items in the SNA node configuration file for switched virtual circuits (SVCs) of an SNA/X.25 link. Each NMMGR screen field is described later in this chapter.

Table 2-3 Host Macro Values for X.25 Link SVC

Host Configuration Macro and Operand

Field in NMMGR Screen

SNA Node NMMGR Screen

X25.LINE TYPEVirtual Circuit TypeX.25 Link Data
CALLCall DirectionX.25 Link Data
PATH DIALNORemote's X.25 Network AddressX.25 Link Data
PU PUNAMESNA Node NameConfiguration
New NameConfiguration
IDBLKID BLKPU Data
IDNUMID NUMPU Data
MAXDATAMAX DATAPU Data
LU LUNAMELU NameLU Data
LOCADDRLU#LU Data

Table 2-4 "Host Macro Values for X.25 System Access" shows the relationships between items from the host configuration and items in the X.25 System Access configuration. The HP SNA Products Remote System Configuration Guide explains the host configuration. See the appropriate NS documentation for more information about the X.25 System Access configuration.

Table 2-4 Host Macro Values for X.25 System Access

Host Configuration Macro

Field in NMMGR Screen

Network Services NMMGR Screen

X25.OUFT INDEXSet NameX.25 User Facility Sets

Note that once the facility set to be used by SNA/X.25 Link is specified in the INDEX operand of the X25.OUFT host macro, it must also be referenced by the OUFINDX operand of the X25.LINE host macro.

Table 2-5 "Host Macro Values for DTC Manager (X.25)" shows the relationship between items from the host configuration and items in the DTC Manager configuration. The HP SNA Products Remote System Configuration Guide explains the host configuration. See the appropriate DTC documentation for more information about the DTC Manager configuration through OpenView.

Table 2-5 Host Macro Values for DTC Manager (X.25)

Host Configuration Macro and Operand

Field in OpenView Screen

DTC Manager OpenView Screen

X25.VCCPT VWINDOWWindow SizeX.25 Level 3


NOTE: Although it is not an X.25 standard requirement, we recommend that the value specified in the Window Size field match the VWINDOW operand of the X25.VCCPT host macro.

Table 2-6 "Host Macro Values for DTS Configuration (X.25)" shows the relationship between items from the host configuration and items in the DTS configuration (for NS host-based network management). The HP SNA Products Remote System Configuration Guide explains the host configuration. See the appropriate NS host-based network management documentation for more information about the DTS configuration through OpenView.

Table 2-6 Host Macro Values for DTS Configuration (X.25)

Host Configuration Macro and Operand

Field in NMMGR Screen

DTS NMMGR Screen

X25.VCCPT VWINDOWWindow Size DTC X.25 Card Configuration — Level 3 & Miscellaneous

SNA/Token Ring Information

For the host and the HP e3000 to communicate, you must coordinate the SNA/Token Ring node configuration with the ACF/NCP and ACF/VTAM host configurations. The HP SNA Products Remote System Configuration Guide explains these configurations. Table 2-7 "Host Macro Values for Token Ring" shows the relationships between items from the host configuration and items in the SNA node configuration file for an SNA/Token Ring link. Each NMMGR screen field is described later in this chapter.

Table 2-7 Host Macro Values for Token Ring

Host Configuration Macro and Operand

Field in NMMGR Screen

NMMGR Screen Name

LINE LOCADDRemote Station AddressToken Ring Link Data
PU PUNAMESNA Node NameConfiguration
New NameConfiguration
IDBLKID BLKPU Data
IDNUMID NUMPU Data
MAXDATAMAX DATAPU Data
LU LUNAMELU NameLU Data
LOCADDRLU#LU Data




HP e3000 Configuration Overview


Data Required from the AS/400 Configuration