HP 3000 Manuals

Messages 4000 - 4999 (continued) [ Information Access Server: Error Messages ] MPE/iX 5.0 Documentation


Information Access Server: Error Messages

Messages 4000 - 4999 (continued) 

--------------------------------------------------------------------------------------

AC4258              ERROR-Cannot delete your own access group

                    Generated by:  Administrator Utility

                    You tried to delete your own access group at the Delete Access
                    Group screen.

                     Have your primary DBA put you into a different access group, and
                    then delete the other access group.

--------------------------------------------------------------------------------------

AC4259              Cannot remove your own DBA capability

                    Generated by:  Administrator Utility

                    You tried to remove the DBA capability from your own user
                    definition a the Change User screen.

                     Have your primary DBA remove your DBA capability.

--------------------------------------------------------------------------------------

AC4260              ERROR-INFO supplied without an editor specified

                    Generated by:  Administrator Utility

                    There are non-blank characters in the INFO field in the Configure
                    View Table Editor screen, but no file information is given.

                     To specify a view table editor, enter complete file information.
                    To specify no view table editor, blank out all fields.

--------------------------------------------------------------------------------------

AC4261              ERROR-PARM supplied without an editor specified

                    Generated by:  Administrator Utility

                    There are non-blank characters in the PARM field in the Configure
                    View Table Editor screen, but no file information is given.

                     To specify a view table editor, enter complete file information.
                    To specify no view table editor, blank out all fields.

--------------------------------------------------------------------------------------

AC4262              ERROR-INFO value must be between -32768 and 32767

                    Generated by:  Administrator Utility

                    The value in the INFO field in the Configure View Table Editor
                    screen is invalid.

                     Leave the field blank, or specify an integer within the given
                    range.
--------------------------------------------------------------------------------------

AC4298              INTERNAL ERROR-No items in the file table

                    Generated by:  Administrator Utility

                    When adding a file table definition, a file table was specified
                    from which to copy the item definition.  The dictionary says there
                    are no items associated with the file table.  This indicates that
                    the data dictionary is probably corrupt.

                     Use dictionary recovery procedures.

          Table 1-0.  (cont.) 

--------------------------------------------------------------------------------------

AC4300              ERROR-name clause too big to display.  Configure a view table &
                    editor

                    Generated by:  Administrator Utility

                    The view table definition was created using an editor.  An attempt
                    was made to change the definition using the V/3000 screens but the
                    clause specified does not fit these screens.

                     Configure an editor and then change the view table definition
                    using the editor.

--------------------------------------------------------------------------------------

AC4301              ERROR-Item name can't be blank

                    Generated by:  Administrator Utility

                    You did not enter a name in the Item field.

                     Enter an item name.  On IMAGE or File table screens, either blank
                    out the Order field or type an item name in the Item field.

--------------------------------------------------------------------------------------

AC4303              ERROR-Can't add security to reserved table name 

                    Generated by:  Administrator Utility

                    Certain table definitions are predefined in Access Server during
                    installation; the security for these tables cannot be changed.

--------------------------------------------------------------------------------------

AC4311              ERROR-Report option value must be between 1 and number 

                    Generated by:  Administrator Utility
--------------------------------------------------------------------------------------

AC4313              ERROR-Invalid capability value for access group name 

                    Generated by:  Administrator Utility

                    While printing a report on access groups, the capability value in
                    the sorted record for the access group is a value other than 1, 2,
                    or 3, even though the unsorted record contained a valid value.
                    The data dictionary has probably been corrupted.

                     Restore an uncorrupted version of Access Server from a backup
                    tape.  To ensure that saved table data and the data dictionary are
                    coordinated, the groups PPCSAVE.HPOFFICE and PPCDICT.HPOFFICE
                    should be restored from the same backup tape.

--------------------------------------------------------------------------------------

AC4314              ERROR-Report option specified is available only to DBA ADMIN

                    Generated by:  Administrator Utility

                    Secondary DBAs cannot report on remote HP 3000 systems.  All other
                    report options are available to them.

                     Select another option or ask your primary DBA to generate the
                    report on remote HP 3000 systems for you.

          Table 1-0.  (cont.) 

--------------------------------------------------------------------------------------

AC4315              ERROR-You must select at least one report to print

                    No report was selected at the Report on Configuration screen or
                    the Report on System Status screen.

                     Select at least one of the reports, or choose  Done  to leave the
                    screen.

--------------------------------------------------------------------------------------

AC4321              ERROR-There is no information to print

                    Generated by:  Administrator Utility

                    A report was selected on the Report on Configuration screen or the
                    Report on System Status screen, but there are no entries in the
                    data dictionary to include in that particular report.

--------------------------------------------------------------------------------------

AC4525              ERROR-Character set selected is already the site character set

                    Generated by:  Administrator Utility

                    The Administrator Utility was run with parm=8 to specify the
                    character set to use with Access Server on the HP 3000.  The set
                    specified is already the one being used, and will continue to be
                    used.
--------------------------------------------------------------------------------------

AC4526              ERROR-Invalid character set number specified

                    Generated by:  Administrator Utility

                    The Administrator Utility was run with parm=8 to specify the
                    character set to use with Access Server on the HP 3000.  The
                    number specified is not in the range of 0 through 9, inclusive,
                    which represent the ten character sets supported.  See the
                    Information Access Server:  Database Administrator manual for more
                    information about supported character sets.

--------------------------------------------------------------------------------------

AC4600              ERROR-FSERR number:  Failed to open view table text file name 

                    Generated by:  Administrator Utility

                    When adding or changing a view table definition with an editor
                    configured, an FOPEN failed on the work file, with the given
                    FSERR.

                     Respond to the FSERR specified.

--------------------------------------------------------------------------------------

AC4601              ERROR-FSERR number:  Failed to close view table file name 

                    Generated by:  Administrator Utility

                    When adding or changing a view table definition with an editor
                    configured, an FCLOSE failed on the work file, with the given
                    FSERR.

                     Respond to the FSERR specified.

          Table 1-0.  (cont.) 

--------------------------------------------------------------------------------------

AC4602              ERROR-FSERR number:  Unable to read from view table file name 

                    Generated by:  Administrator Utility

                    When adding or changing a view table definition with an editor
                    configured, an FREAD failed on the work file, with the given
                    FSERR.

                     Respond to the FSERR specified.
--------------------------------------------------------------------------------------

AC4603              ERROR-FSERR number:  Unable to open editor name 

                    Generated by:  Administrator Utility

                    When adding or changing a view table definition with an editor
                    configured, an FOPEN failed on the editor file, with the given
                    FSERR.

                     Respond to the FSERR specified.

--------------------------------------------------------------------------------------

AC4604              ERROR-FSERR number:  Unable to close editor name 

                    Generated by:  Administrator Utility

                    When adding or changing a view table definition with an editor
                    configured, an FCLOSE failed on the editor file, with the given
                    FSERR.

                     Respond to the FSERR specified.

--------------------------------------------------------------------------------------

AC4605              ERROR-CREATEPROCESS ERROR number:  Unable to execute editor

                    Generated by:  Administrator Utility

                    When adding or changing a view table definition with an editor
                    configured, Information Access Server was unable to spawn a
                    process for the editor to run under, with the given CREATEPROCESS
                    ERROR.

                     Respond to the CREATEPROCESS error specified.

--------------------------------------------------------------------------------------

AC4606              ERROR-FSERR number:  Unable to build view table work file name 

                    Generated by:  Administrator Utility

                    When adding or changing a view table definition with an editor
                    configured, Access Server was unable to successfully FOPEN or
                    FCLOSE a new work file, with the given FSERR.

                     Respond to the FSERR specified.

--------------------------------------------------------------------------------------

AC4607              INTERNAL ERROR-Editor account name can't be blank

                    Generated by:  Administrator Utility

                    When adding or changing a view table definition with an editor
                    configured, Access Server found that the editor definition in the
                    data dictionary lacked an MPE account name.

                     Respecify the editor with the Configure View Table Editor screen,
                    then try again to add or change the view table definition.  If the
                    problem persists, consult your HP representative.

          Table 1-0.  (cont.) 

--------------------------------------------------------------------------------------

AC4608              INTERNAL ERROR-Editor group name can't be blank

                    Generated by:  Administrator Utility

                    When adding or changing a view table definition with an editor
                    configured, Access Server found that the editor definition in the
                    data dictionary lacked an MPE group name.

                     Respecify the editor with the Configure View Table Editor screen,
                    then try again to add or change the view table definition.  If the
                    problem persists, consult your HP representative.

--------------------------------------------------------------------------------------

AC4609              ERROR-Only 1024 characters allowed in an Item Clause

                    Generated by:  Administrator Utility

                    When adding or changing a view table definition with an editor,
                    the maximum number of characters allowed in an Item Clause was
                    exceeded.

                     Re-edit the view table definition, or cancel adding or changing
                    the view table definition.

--------------------------------------------------------------------------------------

AC4610              ERROR-Only 640 characters allowed in a Using Clause

                    Generated by:  Administrator Utility

                    When adding or changing a view table definition with an editor,
                    the maximum number of characters allowed in a Using Clause was
                    exceeded.

                     See the action for AC4609.

--------------------------------------------------------------------------------------

AC4611              ERROR-Only 640 characters allowed in a Where Clause

                    Generated by:  Administrator Utility

                    When adding or changing a view table definition with an editor,
                    the maximum number of characters allowed in a Where Clause was
                    exceeded.

                     See the action for AC4609.

--------------------------------------------------------------------------------------

AC4612              ERROR-Only 160 characters allowed in a Sort Clause

                    Generated by:  Administrator Utility

                    When adding or changing a view table definition with an editor,
                    the maximum number of characters allowed in a Sort Clause was
                    exceeded.

                     See the action for AC4609.
--------------------------------------------------------------------------------------

AC4613              ERROR-FSERR number:  Unable to write to view table file name 

                    Generated by:  Administrator Utility

                    When adding or changing a view table definition with an editor
                    configured, an FWRITE failed on the workfile, with the given
                    FSERR.

                     Respond to the FSERR specified.

          Table 1-0.  (cont.) 

--------------------------------------------------------------------------------------

AC4614              ERROR-Must define an Item Clause

                    Generated by:  Administrator Utility

                    When adding or changing a view table, an Item Clause must be
                    specified.

                     See the action for AC4609.

--------------------------------------------------------------------------------------

AC4615              ERROR-Must define a Using Clause

                    Generated by:  Administrator Utility

                    When adding or changing a view table, a Using Clause must be
                    specified.

                     See the action for AC4609.

--------------------------------------------------------------------------------------

AC4616              ERROR-Clause identifiers must begin with *** starting in column 1

                    Generated by:  Administrator Utility

                    When using an editor to add or change a view table definition,
                    each clause must begin with a clause identifier of three asterisks
                    (***) starting in column one.

                     See the action for AC4609.

--------------------------------------------------------------------------------------

AC4617              ERROR-Invalid clause identifier

                    Generated by:  Administrator Utility

                    The clause identifier in a view table definition must have three
                    asterisks (***) starting in column one.

                     See the action for AC4609.
--------------------------------------------------------------------------------------

AC4701              ERROR-Synchronization option value must be between 1 and number 

                    Generated by:  Administrator Utility

--------------------------------------------------------------------------------------

AC4705              ERROR-Batch file name can't be blank

                    Generated by:  Administrator Utility

                    On the Synchronization Main screen, a group and/or lockword was
                    specified, but no file name was supplied.

                     Either specify a file name (if you want a batch input file to be
                    created), or be sure the group and lockword fields are blank.

--------------------------------------------------------------------------------------

AC4706              ERROR-Invalid batch file name name 

                    Generated by:  Administrator Utility

--------------------------------------------------------------------------------------

AC4708              ERROR-Invalid group name name 

                    Generated by:  Administrator Utility

          Table 1-0.  (cont.) 

--------------------------------------------------------------------------------------

AC4710              ERROR-Invalid batch file lockword

                    Generated by:  Administrator Utility

--------------------------------------------------------------------------------------

AC4711              ERROR-No disc space to create synchronization batch file

                    Generated by:  Administrator Utility

                    When using the Synchronization Main screen to specify the batch
                    input file, a file system error 61 or 62 occurred trying to FOPEN
                    the file with 1023 records.

                     Increase the disc space limit for the group and account, delete
                    files, or do the synchronization interactively.

--------------------------------------------------------------------------------------

AC4712              ERROR-Unable to create synchronization batch file, FSERR number 

                    Generated by:  Administrator Utility

                     Respond to the FSERR specified.
--------------------------------------------------------------------------------------

AC4713              ERROR-Account name cannot be blank

                    Generated by:  Administrator Utility

                    At the Configure View Table Editor screen, the Editor and Group
                    fields were filled in, but the Account field was blank.

                     Enter the account name.

--------------------------------------------------------------------------------------

AC4714              ERROR-An MPE security violation prevents access to editor file

                    Generated by:  Administrator Utility

                    At the Configure View Table Editor screen, an attempt to FOPEN the
                    editor file failed with an FSERR 93, indicating an MPE security
                    violation.

                     Try to run the view table editor interactively, then consult your
                    System Manager.

--------------------------------------------------------------------------------------

AC4715              ERROR-Group name does not exist

                    Generated by:  Administrator Utility

                    You were running the Administrator Utility with parm=10 to process
                    a batch input file.  A file equation equating the file ADMSYNC to
                    the actual input file specified a group that does not exist.

                     Correct the file equation.

--------------------------------------------------------------------------------------

AC4716              ERROR-Account name does not exist

                    Generated by:  Administrator Utility

                    You were running the Administrator Utility with parm=10 to process
                    a batch input file.  A file equation equating the file ADMSYNC to
                    the actual input file specified an account that does not exist.

                     Correct the file equation.

          Table 1-0.  (cont.) 
--------------------------------------------------------------------------------------

AC4720              ERROR-Batch file name doesn't exist in specified group and account

                    Generated by:  Administrator Utility

                    You were running the Administrator Utility with parm=10 to process
                    a batch input file.  A file equation equating the file ADMSYNC to
                    the actual input file specified a file that does not exist.

                     Find the actual location of the file and correct the file
                    equation for ADMSYNC.

--------------------------------------------------------------------------------------

AC4721              ERROR-Incorrect lockword name specified for batch file

                    Generated by:  Administrator Utility

                    You were unning the Administrator Utility with parm=10 to process
                    a batch input file.  A file equation equating the file ADMSYNC to
                    the actual input file specified an invalid lockword for the input
                    file.

                     Change the lockword in the file equation for ADMSYNC.

--------------------------------------------------------------------------------------

AC4722              ERROR-Unable to open synchronization batch file, FSERR number 

                    Generated by:  Administrator Utility

                    You were running the Administrator Utility with parm=10 to process
                    a batch input file.  An error occurred trying to open the file.

                     Check the file equation for the file ADMSYNC and respond to the
                    FSERR specified.

--------------------------------------------------------------------------------------

AC4723              ERROR-An MPE security violation prevents access to batch file

                    Generated by:  Administrator Utility

                    You were running the Administrator Utility with parm=10 to process
                    a batch input file.  A security violation error occurred trying to
                    open the file.

                     Check the file equation for the file ADMSYNC. Make the necessary
                    changes so the logon being used has read access to the batch input
                    file.
--------------------------------------------------------------------------------------

AC4724              ERROR-Synchronization batch file is being accessed exclusively

                    Generated by:  Administrator Utility

                    You were running the Administrator Utility with parm=10 to process
                    a batch input file.  An exclusive access violation occurred trying
                    to open the file.

                     Check the file equation for the file ADMSYNC. Use :LISTF or
                    :LISTDIR5.PUB.SYS to confirm whether or not someone else is
                    currently accessing the file.  Wait until the file is available
                    and try again.

          Table 1-0.  (cont.) 

--------------------------------------------------------------------------------------

AC4725              ERROR-Unrecognizable record in synchronization batch file

                    Generated by:  Administrator Utility

                    You were running the Administrator Utility with parm=10 to process
                    a batch input file.  One of the records in the file is
                    unrecognizable.  (See the Information Access Server:  Database 
                    Administration manual for the correct record format.)

                     Check the format of the file to make sure it is correct.  Look
                    for non-blank characters after the last field for each option and
                    valid option numbers as the first character on each line (followed
                    by a blank).  Note that files must be kept unnumbered.

--------------------------------------------------------------------------------------

AC4729              IMSAM mismatch, item name. Dict=name, source=value 

                    Generated by:  Administrator Utility

                    When synchronizing an IMAGE table definition that is derived from
                    a database that is enhanced by IMSAM, a mismatch was found on the
                    IMSAM flags for the item specified.

--------------------------------------------------------------------------------------

AC4730              ERROR-Item name does not exist in the data source

                    Generated by:  Administrator Utility

                    When synchronizing a table definition, an item associated with a
                    table defined in the Access Server data dictionary has been
                    deleted from the data source.

                     Delete the item from the table using the Change Table screens in
                    the Administrator Utility.
--------------------------------------------------------------------------------------

AC4731              Type mismatch, item name.  Dict=name, source=value 

                    Generated by:  Administrator Utility

                    When synchronizing a table definition, the type of an item
                    associated with a table defined in the data dictionary was found
                    to be a different type than it is in the IMAGE dataset.  (If type
                    conversions are automatically performed by Access Server, the
                    Administrator Utility will consider the converted type equivalent
                    to the original type in the dataset.)  For example, the data
                    dictionary has the item as type integer but the dataset has it as
                    type real.

                    The source in the message is a value in the IMAGE dataset (for an
                    IMAGE table) or in the source table definition (for view tables).

                     Using the Change Table screens in the Administrator Utility,
                    press Enter and the current (correct) information will be stored
                    in the data dictionary.

          Table 1-0.  (cont.) 

--------------------------------------------------------------------------------------

AC4732              Length mismatch, item name|.  Dict=name, source=name 

                    Generated by:  Administrator Utility

                    When synchronizing a table definition, the length of an item
                    associated with a table defined in the data dictionary was not the
                    same as it is in the IMAGE dataset.

                    The source in the message is a value in the IMAGE dataset (for an
                    IMAGE table) or in the source table definition (for view tables).

                     Using the Change Table screens in the Administrator Utility,
                    press Enter and the current (correct) definition will be stored in
                    the data dictionary.

--------------------------------------------------------------------------------------

AC4733              Array bound mismatch, item name.  Dict=name, source=name 

                    Generated by:  Administrator Utility

                    When synchronizing a table definition, the array bound of an item
                    associated with a table defined in the data dictionary is not the
                    same as it is in the IMAGE dataset.  (This error only occurs for
                    IMAGE and view tables).

                    The source in the message is a value in the IMAGE dataset (for an
                    IMAGE table) or in the source table definition (for view tables).

                     Using the Change Table screens in the Administrator Utility,
                    press Enter and the current (correct) definition will be stored in
                    the dictionary.
--------------------------------------------------------------------------------------

AC4736              Item kind mismatch, item name.  Dict=name, source=name 

                    Generated by:  Administrator Utility

                    When synchronizing an IMAGE table or a view table, the table list
                    generated by the Administrator Utility was found to have a table
                    in it that is not an IMAGE table, a file, or a view table.  This
                    is an internal error condition.

                     Report the error to your HP representative.  The other tables
                    will be checked for synchronization normally.

--------------------------------------------------------------------------------------

AC4740              There are no error messages for this table

                    Generated by:  Administrator Utility

                    This is an informational message indicating that no
                    synchronization errors were detected for this table.

--------------------------------------------------------------------------------------

AC4741              ERROR-Select at least 1 table or choose Done

                    Generated by:  Administrator Utility

                    The Enter key was pressed on the Synchronization Summary screen,
                    but no table has been selected for which to show synchronization
                    errors.

          Table 1-0.  (cont.) 

--------------------------------------------------------------------------------------

AC4745              INTERNAL ERROR-Too many synchronization errors, workfile overflow

                    Generated by:  Administrator Utility

                    When synchronizing a table, the workfile containing
                    synchronization error messages can take up to 32,767 messages.
                    This message occurs if that limit is reached.

                     Select a narrower synchronization option and try again.

--------------------------------------------------------------------------------------

AC4746              Table item name not found in file at offset number 

                    Generated by:  Administrator Utility

                    When synchronizing a file table, an item defined in the file table
                    had no counterpart in the file at the offset given in the table
                    definition.

                     This may be an error in item definition.  Or it may be that
                    you've defined a new item that is a subset of an existing item or
                    that straddles items.
--------------------------------------------------------------------------------------

AC4747              Table item name identical to file item name 

                    Generated by:  Administrator Utility

                    When synchronizing a table definition, an item defined in the file
                    table had a counterpart in the file with the same type, offset,
                    and length, but the names differed.

                     This is probably not an error.  It indicates that you have chosen
                    to rename the item when its table is called into Access Server.

--------------------------------------------------------------------------------------

AC4748              Item name has length length in table, length in file

                    Generated by:  Administrator Utility

                    When synchronizing a file table, an item defined in the file table
                    had a counterpart in the file with the same name (if not a KSAM
                    item), type, and offset, but the lengths differed.

                     This may be an error in item definition.  Or it may be that you
                    redefined the item in the table to include only the first part of
                    the file item.

--------------------------------------------------------------------------------------

AC4749              Table item name differs in name and length in file

                    Generated by:  Administrator Utility

                    When synchronizing a file table, an item defined in the file table
                    had a counterpart in the file with the same type and offset, but
                    the names and lengths differed.  The two lines that follow set out
                    the differences.

                     This may be an error in item definition.  Or it may be that you
                    want to redefine the item in the table in this way.

          Table 1-0.  (cont.) 

--------------------------------------------------------------------------------------

AC4750              Item name is type type in table, type in file

                    Generated by:  Administrator Utility

                    When synchronizing a file table, an item defined in the file table
                    had a counterpart in the file with the same name (if not a KSAM
                    item), offset, and length, but the types differed.

                     This may be an error in item definition.  Or it may be that you
                    want to redefine the type of the item in the table.
--------------------------------------------------------------------------------------

AC4751              Table item name differs in name and type in file

                    Generated by:  Administrator Utility

                    When synchronizing a file table, an item defined in the file table
                    had a counterpart in the file with the same length and offset, but
                    the names and types differed.  The two lines that follow set out
                    the differences.

                     This may be an error in item definition.  Or it may be that you
                    want to redefine the item in the table in this way.

--------------------------------------------------------------------------------------

AC4752              Table item name differs in type and length in file

                    Generated by:  Administrator Utility

                    When synchronizing a file table, an item defined in the file table
                    had a counterpart in the file with the same name (if not a KSAM
                    file) and offset, but the types and lengths differed.  The two
                    lines that follow set out the differences.

                     This may be an error in item definition.  Or it may be that you
                    want to redefine the item in the table in this way.

--------------------------------------------------------------------------------------

AC4753              Table item name differs in name, type, length in file

                    Generated by:  Administrator Utility

                    When synchronizing a file table, an item defined in the file table
                    had a counterpart in the file with the same offset, but the names,
                    types, and lengths differed.  The three lines that follow set out
                    the differences.

                     This may be an error in item definition.  Or it may be that you
                    want to redefine the item in the table in this way.

--------------------------------------------------------------------------------------

AC4754              Item name offset plus length exceeds file record length

                    Generated by:  Administrator Utility

                    When synchronizing a file table, the item as defined in the file
                    table went past the end of the file record.

                     Recheck your item definition and adjust the offset and length
                    accordingly with the Change File Table screen.

          Table 1-0.  (cont.) 
--------------------------------------------------------------------------------------

AC4755              File type, unknown when table was added, is currently type 

                    Generated by:  Administrator Utility

                    The file table definition was added when the file was not
                    available.  During the synchronization request, the file was found
                    and its type is noted here.

                     This message is primarily informational.  No error is indicated.

--------------------------------------------------------------------------------------

AC4756              File type mismatch.  Dict=name, source=name 

                    Generated by:  Administrator Utility

                    When the file definition was added it was one type; now, in
                    synchronizing tables derived from it, the current file on the
                    system is of a different type.

                     Verify that any file equations for the file are correct.

--------------------------------------------------------------------------------------

AC4757              Item name offset plus length exceeds number byte maximum

                    Generated by:  Administrator Utility

                    When synchronizing a file table, the item as defined in the file
                    goes past the end of the maximum length record Access Server will
                    read (currently the first 2048 bytes of the record).

                     Recheck your item definition and adjust the offset and length
                    accordingly with the Change File Table screen.

--------------------------------------------------------------------------------------

AC4758              Record number byte number of item name has bad numeric data

                    Generated by:  Administrator Utility

                    When synchronizing a file table, an item identified in the table
                    definition as being of type numeric showed invalid numeric data at
                    the specified byte in the specified record.  This indicates the
                    first invalid byte in the item; no checking is done beyond it.

                     Recheck the definition of the item in the file and make any
                    necessary changes with the Change File Table screen.  Then attempt
                    the synchronization again.
--------------------------------------------------------------------------------------

AC4759              Record number byte number of item name has bad zoned data

                    Generated by:  Administrator Utility

                    When synchronizing a file table, an item identified in the table
                    definition as being of type zoned showed invalid zoned data at the
                    specified byte in the specified record.  This indicates the first
                    invalid byte in the item; no checking is done beyond it.

                     Recheck the definition of the item in the file and make any
                    necessary changes with the Change File Table screen.  Then attempt
                    the synchronization again.

          Table 1-0.  (cont.) 

--------------------------------------------------------------------------------------

AC4760              Record number nibble number of item name has bad packed data

                    Generated by:  Administrator Utility

                    When synchronizing a file table, an item identified in the table
                    definition as being of type packed showed invalid packed data at
                    the indicated nibble in the indicated record.  This indicates the
                    first invalid nibble in the item; no checking is done beyond it.

                     Recheck the definition of the item in the file and make any
                    necessary changes with the Change File Table screen.  Then attempt
                    the synchronization again.

--------------------------------------------------------------------------------------

AC4761              File does not currently exist in the specified location

                    Generated by:  Administrator Utility

                    While synchronizing a file table definition, the file was not
                    found in the group (and possibly account) specified in the file
                    definition.  This may or may not be an error depending on how file
                    equations are used and whether or not the file is always present
                    on the system.

                     Make sure the file is accessible before you try to synchronize
                    the definitions of file tables.

--------------------------------------------------------------------------------------

AC4762              Items name and name overlap

                    Generated by:  Administrator Utility

                    When synchronizing a file table definition, two items of data
                    types other than both C and/or N overlap.  This is probably an
                    error in the way the DBA has defined the file table, unless it is
                    being done on purpose.
--------------------------------------------------------------------------------------

AC4763              Character items name and name overlap

                    Generated by:  Administrator Utility

                    When synchronizing a file table definition, two items both having
                    data types C and/or N overlap.  This may or may not be an error in
                    the way the DBA has defined the file table, depending on the
                    desired results.

--------------------------------------------------------------------------------------

AC4888              ERROR-Blank view table text file

                    Generated by:  Administrator Utility

                    When adding or changing a view table definition with an editor
                    configured, the text file was found to contain no records upon
                    returning from your editor.

                     Be sure to leave the templates in the file.  These are required
                    for Information Access Server to interpret the file correctly.
                    Also, make sure your view table contains an Item Clause and a
                    Using Clause.

          Table 1-0.  (cont.) 

--------------------------------------------------------------------------------------

AC4901              ERROR-Native Language Support error number in NLFMTCUSTDATE

                    Generated by:  Administrator Utility

                    An error occurred during a call to the NLFMTCUSTDATE intrinsic
                    somewhere in the Administrator Utility.

                     Respond to the NLS error specified.  If unable to resolve it,
                    record the exact sequence of operations leading up to the error
                    before you call your HP representative for assistance.

--------------------------------------------------------------------------------------

AC4902              ERROR-Native Language Support error number in NLFMTCLOCK

                    Generated by:  Administrator Utility

                    An error occurred during a call to the NLFMTCLOCK intrinsic
                    somewhere in the Administrator Utility.

                     Respond to the NLS error specified.  If unable to resolve it,
                    record the exact sequence of operations leading up to the error
                    before you call your HP representative for assistance.
--------------------------------------------------------------------------------------

AC4903              ERROR-Native Language Support error number in NLFMTDATE

                    Generated by:  Administrator Utility

                    An error occurred during a call to the NLFMTDATE intrinsic
                    somewhere in the Administrator Utility.

                     Respond to the NLS error specified.  If unable to resolve it,
                    record the exact sequence of operations leading up to the error
                    before you call your HP representative for assistance.

--------------------------------------------------------------------------------------

AC4911              ERROR-Sort error number in SORTINIT

                    Generated by:  Administrator Utility

                    An error occurred during a call to the SORTINIT intrinsic
                    somewhere in the Administrator Utility.

                     Respond to the sort error specified.  If unable to resolve it,
                    record the exact sequence of operations leading up to the error
                    before you call your HP representative for assistance.

--------------------------------------------------------------------------------------

AC4912              ERROR-Sort error number in SORTINPUT

                    Generated by:  Administrator Utility

                    An error occurred during a call to the SORTINPUT intrinsic
                    somewhere in the Administrator Utility.

                     Respond to the sort error specified.  If unable to resolve it,
                    record the exact sequence of operations leading up to the error
                    before you call your HP representative for assistance.

          Table 1-0.  (cont.) 

--------------------------------------------------------------------------------------

AC4913              ERROR-Sort error number in SORTOUTPUT

                    Generated by:  Administrator Utility

                    An error occurred during a call to the SORTOUTPUT intrinsic
                    somewhere in the Administrator Utility.

                     Respond to the sort error specified.  If unable to resolve it,
                    record the exact sequence of operations leading up to the error
                    before you call your HP representative for assistance.
--------------------------------------------------------------------------------------

AC4914              ERROR-Sort error number in SORTEND

                    Generated by:  Administrator Utility

                    An error occurred during a call to the SORTEND intrinsic somewhere
                    in the Administrator Utility.

                     Respond to the sort error specified.  If unable to resolve it,
                    record the exact sequence of operations leading up to the error
                    before you call your HP representative for assistance.

--------------------------------------------------------------------------------------

AC4921              ERROR-FSERR number in FOPEN on file name|

                    Generated by:  Administrator Utility

                    An error occurred during a call to the FOPEN intrinsic somewhere
                    in the Administrator Utility.

                     Respond to the FSERR error specified.  If unable to resolve it,
                    record the exact sequence of operations leading up to the error as
                    well as the file name specified before you call your HP
                    representative for assistance.

--------------------------------------------------------------------------------------

AC4922              ERROR-FSERR number in FREAD on file name 

                    Generated by:  Administrator Utility

                    An error occurred during a call to the FREAD intrinsic somewhere
                    in the Administrator Utility.

                     See action for AC4921.

--------------------------------------------------------------------------------------

AC4923              ERROR-FSERR number in FWRITE on file name 

                    Generated by:  Administrator Utility

                    An error occurred during a call to the FWRITE intrinsic somewhere
                    in the Administrator Utility.

                     See action for AC4921.

          Table 1-0.  (cont.) 

--------------------------------------------------------------------------------------

AC4924              ERROR-FSERR number in FCLOSE on file name 

                    Generated by:  Administrator Utility

                    An error occurred during a call to the FCLOSE intrinsic somewhere
                    in the Administrator Utility.

                     See action for AC4921.
--------------------------------------------------------------------------------------

AC4925              ERROR-FSERR number in FPOINT on file name 

                    Generated by:  Administrator Utility

                    An error occurred during a call to the FPOINT intrinsic somewhere
                    in the Administrator Utility.

                     See action for AC4921.

--------------------------------------------------------------------------------------

AC4926              ERROR-FSERR number in FCONTROL on file name 

                    Generated by:  Administrator Utility

                    An error occurred during a call to the FCONTROL intrinsic
                    somewhere in the Administrator Utility.

                     See action for AC4921.

--------------------------------------------------------------------------------------

AC4927              ERROR-FSERR number in FSPACE on file name 

                    Generated by:  Administrator Utility

                    An error occurred during a call to the FSPACE intrinsic somewhere
                    in the Administrator Utility.

                     See action for AC4921.

--------------------------------------------------------------------------------------

AC4928              ERROR-FSERR number in FFILEINFO on file name 

                    Generated by:  Administrator Utility

                    An error occurred during a call to the FFILEINFO intrinsic
                    somewhere in the Administrator Utility.

                     See action for AC4921.

--------------------------------------------------------------------------------------

AC4929              ERROR-FSERR number in FREADDIR on file name 

                    Generated by:  Administrator Utility

                    An error occurred during a call to the FREADDIR intrinsic
                    somewhere in the Administrator Utility.

                     See action for AC4921.

          Table 1-0.  (cont.) 
--------------------------------------------------------------------------------------

AC4941              ERROR-MPE intrinsic error number in BINARY

                    Generated by:  Administrator Utility

                    An error occurred during a call to the BINARY intrinsic somewhere
                    in the Administrator Utility.

                     Respond to the intrinsic error specified.  If unable to resolve
                    it, record the exact sequence of operations leading up to the
                    error and call your HP representative.

--------------------------------------------------------------------------------------

AC4942              ERROR-MPE intrinsic error number in DMOVOUT

                    Generated by:  Administrator Utility

                    An error occurred during a call to the DMOVOUT intrinsic somewhere
                    in the Administrator Utility.

                     See action for AC4941.

--------------------------------------------------------------------------------------

AC4943              ERROR-MPE intrinsic error number in DMOVIN

                    Generated by:  Administrator Utility

                    An error occurred during a call to the DMOVIN intrinsic somewhere
                    in the Administrator Utility.

                     See action for AC4941.

--------------------------------------------------------------------------------------

AC4944              ERROR-MPE intrinsic error number in GETDSEG

                    Generated by:  Administrator Utility

                    An error occurred during a call to the GETDSEG intrinsic somewhere
                    in the Administrator Utility.

                     See action for AC4941.



MPE/iX 5.0 Documentation