HP LaserRX/MPE Enhanced [ COMMUNICATOR 3000 MPE MPE/iX RELEASE 4.0 ] MPE/iX Communicators
COMMUNICATOR 3000 MPE MPE/iX RELEASE 4.0
HP LaserRX/MPE Enhanced
by Gerry Wade
Software Technology Division
This release of LaserRX/MPE has several exciting new features. The "B"
version, shipped with XL Release 3.0, added major new functionality over
the original "A" version. Even more enhancements have been made with
this release.
UPDATES SHIPPED WITH MPE/iX
Beginning with MPE/iX Release 4.0 and MPE V Release 23, the LaserRX/MPE
Collection Software may be updated using standard MPE update procedures.
Customers with support for LaserRX/MPE, part number 50700B, receive the
LaserRX/MPE Collector software update along with their other HP 3000
product updates. The LaserRX update is installed by the AUTOINST
program.
CAUTION A new group and user are added to the SYS account as part of the
LaserRX/MPE product support. If they already exist, then their
capabilities are altered as follows:
NEWGROUP SCOPE;CAP=IA,BA,PH,DS,MR,PM
NEWUSER SCOPE;HOME=SCOPE;CAP=GL,ND,SF,IA,BA
The group is added only if the LaserRX/MPE product is being
installed. Since the SCOPE.SYS group requires PM capability,
you will probably want to add a password to this group. The
user is added to every system regardless of whether the
LaserRX/MPE product is being installed. Existing passwords and
access restrictions are not altered.
HOST ACCESS TO DATA
Access to LaserRX log file data is now available on the HP 3000. The
EXTRACT program has a new EXPORT command that produces ASCII or BINARY
files of LaserRX performance data. Flexible output formatting allows
easy generation of custom reports and transfer of data to other analysis
packages.
SERVICE LEVEL SUPPORT
The Performance Data Collector now allows you to specify a target
response time for each LaserRX application. The percentage of terminal
transactions that meet this target is then available as a measure of
service level agreements. The service level agreement percentage is
available using the Host Export facility.
SCHEDULED LOG FILE ADJUSTMENTS
As LaserRX log files become full they are adjusted by rolling out the
oldest 25% of the data. If log files are large, this process may take
place during undesirable times. Now the Data Collector examines each log
file at a user defined time each day and, if it predicts that the log
file will fill in the next 24 hours, adjusts it at that time. This
allows scheduling log file adjustments at off hours, avoiding any
possible impact on critical processing.
LOG FILE ANALYSIS
The UTILITY program has been enhanced to process performance alarms
against LaserRX log file data. This can be used to identify times which
bear closer analysis. It can also be used in a periodic batch job to
scan the latest log file data and take actions automatically if system or
application performance met user defined criteria.