Level: 1 CLAS0003
CAUSE: RFA was unable to obtain a free DST for its buffers.
ACTION: If system is overloaded, wait till resources free up;
otherwise, see Appendix A "Submitting a CR"
of this manual.
MESSAGE: None
Level: 2 CLAS0003
CAUSE: RFA was unable to deallocate one of its internal buffers.
ACTION: If program a has opened too many NOWAIT RFA
files, or if it is attempting to read large blocks of data for each FREAD
(16000 bytes per FREAD), then the program has reached RFA's resource
limits. If the program does neither then see
Appendix A "Submitting a CR"
MESSAGE: None
Level: 3 CLAS0003
CAUSE: RFA was unable to obtain enough memory to create
an internal buffer entry.
ACTION: See Appendix A "Submitting a CR"
of this manual.
MESSAGE: None
Level: 4 CLAS0003
CAUSE: RFA encountered an unexpected error from one of
its buffer management routines.
ACTION: See Appendix A "Submitting a CR"
of this manual.
MESSAGE: None
Level: 5 CLAS0003
CAUSE: RFA could not delete a DST it allocated.
ACTION: See Appendix A "Submitting a CR"
of this manual.
MESSAGE: None
Level: 7 CLAS0003
CAUSE: RFA could not create a socket connection for NOWAIT IO.
ACTION: See Appendix A "Submitting a CR"
of this manual.
MESSAGE: None
Level: 8 CLAS0003
CAUSE: RFA failed to create a connection to the remote machine.
ACTION: Verify if the network transport has not been shutdown by
the system operator on the local or remote system. If not see
Appendix A "Submitting a CR"
of this manual.
MESSAGE: None
Level: 9 CLAS0003
CAUSE: RFA was unable to complete a connection with the
remote machine.
ACTION: Verify if the network transport has not been shutdown by
the system operator on the local or remote system. If not see
Appendix A "Submitting a CR"
MESSAGE: None
Level: 10 CLAS0003
CAUSE: RFA encountered a NetIPC error while sending an
RFA request to the remote system.
ACTION: If the user attempted to FREAD or FWRITE more
than 29980 bytes of data in one FREAD or FWRITE call, then the user
has reached the resource limits of RFA. If user has enabled data
compression for RFA transfers, this limit is 29000 bytes. This error
will also occur if the system operator has brought down the network
transport on the local or remote system. If not, see
Appendix A "Submitting a CR"
MESSAGE: None
Level: 11 CLAS0003
CAUSE: An unexpected error occurred while receiving data
from the remote system.
ACTION: This error will occur if the system operator has
brought down the network transport on the local or remote system.
It can also occur if the version of NS on the remote system is older
than this system and the user attempted to use a newly supported
file system intrinsic that is not supported by RFA on the remote
system. If neither is the case then see
Appendix A "Submitting a CR" of
this manual.
MESSAGE: None
Level: 12 CLAS0003
CAUSE: RFA was unable to completely receive all the data
from a NOWAIT FWRITE.
ACTION: See Appendix A "Submitting a CR"
of this manual.
MESSAGE: None
Level: 13 CLAS0003
CAUSE: While attempting to adjust a NetIPC socket, RFA
encountered an unexpected error.
ACTION: See Appendix A "Submitting a CR"
of this manual.
MESSAGE: None
Level: 14 CLAS0003
CAUSE: RFA could not shutdown a NetIPC socket it created.
ACTION: See Appendix A "Submitting a CR"
of this manual.
MESSAGE: None
Level: 15 CLAS0003
CAUSE: RFA could not connect with the RFA server on the
remote system.
ACTION: Verify that the network transport has been started on the
remote system. Verify that the remote system supports NS 3000/iX RFA. Also
verify that the remote system has started the RFA service. If RFA is
started then see Appendix A "Submitting a CR"
of this manual.
MESSAGE: None
Level: 16 CLAS0003
CAUSE: RFA could not turn on NetIPC socket data tracing.
ACTION: If the local system is not out of disk space then see
Appendix A "Submitting a CR"
of this manual.
MESSAGE: None
Level: 17 CLAS0003
CAUSE: RFA could not update information in the NS DSLINE
table.
ACTION: RFA may have run out of stack space. Run the program with
an additional 2000 words of stack space. If this is not the problem then
see Appendix A "Submitting a CR"
of this manual.
MESSAGE: None
Level: 18 CLAS0003
CAUSE: RFA could not get information from the NS DSLINE
table.
ACTION: RFA may have run out of stack space. Run the program with
an additional 2000 words of stack space. If this is not the problem then
see Appendix A "Submitting a CR"
of this manual.
MESSAGE: None
Level: 19 CLAS0003
CAUSE: RFA could not add a new process entry into the
NS DSLINE table.
ACTION: RFA may have run out of stack space or the DSLINE
table may be full. If there are more than 100 programs in the same session
using NS, the user has reached NS resource limits. Otherwise run the
program with an additional 2000 words of stack space. If this is not the
problem then see Appendix A "Submitting a CR"
of this manual.
MESSAGE: None
Level: 20 CLAS0003
CAUSE: NS has lost track of how many programs are using
the DSLINE table.
ACTION: See Appendix A "Submitting a CR"
of this manual.
MESSAGE: None
Level: 21 CLAS0003
CAUSE: RFA could not find an entry it created in the
DSLINE table.
ACTION: RFA may have run out of stack space. Run the program with
an additional 2000 words of stack space. If this is not the problem then
see Appendix A "Submitting a CR"
of this manual.
MESSAGE: None
Level: 22 CLAS0003
CAUSE: Insufficient memory in the port DST to create a
new port for NOWAIT IO.
ACTION: See Appendix A "Submitting a CR"
of this manual.
MESSAGE: None
Level: 23 CLAS0003
CAUSE: Unexpected error while creating an IOWAIT port for
NOWAIT IO. NOWAIT IO is not currently supported on XL.
ACTION: See Appendix A "Submitting a CR"
of this manual.
MESSAGE: None
Level: 24 CLAS0003
CAUSE: Unexpected error while creating an IOWAIT port for
NOWAIT IO.
ACTION: See Appendix A "Submitting a CR"
of this manual.
MESSAGE: None
Level: 25 CLAS0003
CAUSE: RFA was unable to create or delete an entry in
the DSSERVER's stack.
ACTION: If the remote user has opened many message files and/or
their program FREADs or FWRITEs large amounts of data per request (16000
bytes) then the user has reached the resource limits of RFA. If not see
Appendix A "Submitting a CR"
of this manual.
MESSAGE: None
Level: 27 CLAS0003
CAUSE: The RFA Server received a request it could not execute.
ACTION: If the version of NS on this system is older than the
version of NS on the RFA user's host system and the user attempted to
execute a new file system intrinsic or TurboIMAGE intrinsic that
is not supported by the older revision of NS, this error will occur. This
system must be updated. If not, it is possible that this system has a
duplicate IP address as another system on this network. If this is not the
case, then an RFA message has been corrupted, see
Appendix A "Submitting a CR"
of this manual.
MESSAGE: None
Level: 28 CLAS0003
CAUSE: RFA was unable to setup its data area or NetIPC
connection for NOWAIT IO.
ACTION: See Appendix A "Submitting a CR"
of this manual.
MESSAGE: None
Level: 29 CLAS0003
CAUSE: RFA was unable to setup parameters for the TCP connection.
ACTION: See Appendix A "Submitting a CR"
of this manual.
MESSAGE: None
Level: 30 CLAS0003
CAUSE: While the RFA server was adopting in the remote
session, it could not update information in the AS process table.
ACTION: See Appendix A "Submitting a CR"
of this manual.
MESSAGE: None
Level: 31 CLAS0003
CAUSE: RFA was unable to allocate a buffer large enough
to handle the user's FREAD or FWRITE request.
ACTION: If the user's program a has opened too many
NOWAIT RFA files or if it is attempting to read large blocks of
data for each FREAD (16000 bytes per FREAD) then the
program has reached RFA's resource limits. If the program does neither then
see Appendix A "Submitting a CR" of this
manual.
MESSAGE: None
Level: 32 CLAS0003
CAUSE: The RFA Server's state tables indicate
it is in an expected state.
ACTION: See Appendix A "Submitting a CR"
of this manual.
MESSAGE: None
Level: 33 CLAS0003
CAUSE: An unexpected error was returned from DBCLOSE.
ACTION: See Appendix A "Submitting a CR"
of this manual.
MESSAGE: None
Level: 35 CLAS0003
CAUSE: The user attempted to open a reverse RFA file using
the $BACK environment. RFA was unable to make contact with
the originating system.
ACTION: This problem can occur if the domain and/or organization
of the originating node is different than this node. If this is
the case, add the remote node name to the NS directory file on this
system using the same domain and organization as this node. If this
is not the problem then see Appendix A "Submitting
a CR" of this manual.
MESSAGE: None
Level: 36 CLAS0003
CAUSE: RFA was unable to obtain an NM memory object for
the RFA data compression buffer.
ACTION: See Appendix A "Submitting a CR"
of this manual.
MESSAGE: None
Level: 37 CLAS0003
CAUSE: RFA failed to delete an NM memory object it created.
ACTION: See Appendix A "Submitting a CR"
of this manual.
MESSAGE: None
Level: 38 CLAS0003
CAUSE: RFA could not call one of its Native Mode procedures.
ACTION: The NS product has been installed improperly. See
Appendix A "Submitting a CR"
of this manual.
MESSAGE: None
Level: 39 CLAS0003
CAUSE: One of many possible errors encountered in Native Mode RFA.
ACTION: See Appendix A "Submitting a CR"
of this manual.