The following are the software maximums in Table 1-1 "Configuration Maximums" that must be adhered to when configuring a supported link. These maximums may be further limited by the system hardware (number of available slots). Maximums are also documented throughout the manual for the appropriate screen.

Table 1-1 Configuration Maximums

Screen Number/Description

Path

Maximum Limit

#9 Network Directory Select Node NameNoneFile Size Limit[1]
#85 Link SelectionLINK256/system
#112 Network Interface ConfigurationNETXPORT.NI12 NI/system[2]
#115 Point-to-Point Mapping ConfigurationNETXPORT.NI.NIname.MAPPING1024 Mappings/Router
#117 Gateway Half NI LinksNETXPORT.NI.NIname.LINK1 link/Gateway Half NI
#119 Point-to-Point NI LinksNETXPORT.NI.NIname.40 links/Router NI
#151 X.25 Network Interface LinksNETXPORT.NI.NIname.LINK12 links/X.25 NI
#152 Neighbor GatewaysNETXPORT.NI.NIname.INTERNET255 gateways/NI
#158 Neighbor Gateway Reachable NetworksNETXPORT.NI.NIname.INTERNET.gatewayn2550 nets/NI[3]
#162 X.25 SVC Address Key PathsNETXPORT.NIname.PROTOCOL.X25.SVCPATH2048/X.25 NI
#163 X.25 PVC Address Key PathsNETXPORT.NIname.PROTOCOL.X.25.PVCPATH128/X.25NI
#164 X.25 User Facility SetsNETXPORT.NI.NIname.POROTOCOL.X25.FACSET128/X.25 NI

[1] Maintenance Node command EXPANDDIR may be used to expand the directory file. Refer to Using the Node Management Services (NMS) Utilities manual for information regarding this command.

[2] One NI must be used for loopback.

[3] 2,550 reachable networks (255 pages and 10 reachable nets per page).