HPlogo MPE/iX Intrinsics Reference Manual > Chapter 10 Command Definitions (QUIT-ZSIZE)

STACKDUMP

MPE documents

Complete PDF
Table of Contents
Index

Edition 7 E0701 ♥
Edition 7 E0300
Edition 6 E0195

NM and CM callable (differences noted below).

Calls the system debugger to send a stack trace to $STDLIST or to the file specified in the formaldesig parameter. Control then returns to the calling procedure.

Syntax



             CA           I16V      I16V   I32
  STACKDUMP (formaldesig, idnumber, flags, selec);

(CM: SPL language only)

              CA           I16V      I16V   I32
  STACKDUMP' (formaldesig, idnumber, flags, selec);

Parameters


formaldesig

character array (optional)

Passes the file name of a new output file to be opened. The name is terminated by any nonalphanumeric character except a slash (/) or a period (.). The same restrictions for the formaldesig parameter in the FOPEN intrinsic apply to this parameter.

(CM: SPL language only) If the secondary entry point, STACKDUMP', is used, the first byte of formaldesig contains the file number that was successfully opened prior to the call to STACKDUMP'. In this case, the file is not closed before returning to the calling program. When a file number is passed, the record length must be between 64 bytes and 512 bytes and write access must be allowed for the file.

Default: Dump is sent to $STDLIST.

idnumber

16-bit signed integer by value (optional)

If the intrinsic fails due to a file system error, the file system specific error number of the failure is returned here. Any value passed into the intrinsic through this parameter is ignored.

flags

16-bit unsigned integer by value (optional)

This parameter is provided for compatibility with MPE V/E. If it is present, it is ignored and has no effect.

selec

32-bit integer array by reference (optional)

This parameter is provided for compatibility with MPE V/E. If it is present in the intrinsic call, it is ignored and has no effect.

Condition Codes


CCE (2)Request granted.
CCG (0)Request denied. An invalid address for the location of the formaldesig parameter was detected.
CCL (1)Request denied. File system error occurred during opening, writing to, or closing the file. The file error number is returned in idnumber.

Related Information


Intrinsics DEBUG, HPDEBUG, HPRESETDUMP, HPSETDUMP, RESETDUMP, SETDUMP
CommandsDEBUG, RESETDUMP, SETDUMP
Manuals MPE/iX System Debug Reference Manual
MPE/iX Commands Reference Manual




SORTTITLE