HPlogo MPE/iX Intrinsics Reference Manual > Chapter 10 Command Definitions (QUIT-ZSIZE)

SETJCW

MPE documents

Complete PDF
Table of Contents
Index

Edition 7 E0701 ♥
Edition 7 E0300
Edition 6 E0195

NM and CM callable.

Sets bits in the system job control word (JCW).

Syntax



          U16V
  SETJCW (jcword);

Parameters


jcword

16-bit unsigned integer by value (required)

The user-defined bit contents of the system JCW for interprocess communication.

BitsValue/Meaning>
0:1Reserved for the operating system

If (0:1)=1, the system outputs the following message when the program terminates, either normally or due to an error:

   PROGRAM TERMINATED IN ERROR STATE (CIERR 976)

In batch mode, the job is terminated unless the CONTINUE command is used. If JCW is set to exactly %140000 (bits (0:1)=1 and (1:1)=1 only), the CIERR 976 message is replaced by:

   PROGRAM ABORTED PER USER REQUEST (CIERR 989)

1:15Used for any purpose.

Related Information


Intrinsics FINDJCW, GETJCW, PUTJCW, HPCIDELETEVAR, HPCIGETVAR, HPCIPUTVAR
CommandsDELETEVAR, SETJCW, SETVAR, SHOWJCW, SHOWVAR
Manuals Interprocess Communication Programmer's Guide
Command Interpreter Access and Variables Programmer's Guide
MPE/iX Commands Reference Manual




SETDUMP


SORTEND