To rerun AUTOINST and finish applying the CSLT:
  1. Remount the combined CSLT/store tape created during the first run of AUTOINST.

    If the CSLT is two reels, begin by loading the second reel because the STORE files are appended to the CSLT. The program will prompt you if the first reel is also required.

  2. Reset the outfence.

      :OUTFENCE 14
  3. Run AUTOINST to resume previous installation.

      :RUN AUTOINST.INSTALL.SYS
  4. Respond YES to resume installation.

    If the system displays a message saying that is located an old audit trail of an incomplete installation (that is, HPINSTFL.INSTALL.SYS). You must respond Y and resume the installation to complete the task.

      MPE/iX AUTOINST D.10.11 (C) HEWLETT-PACKARD CO.
      An old audit trail of an incomplete installation has been found.
      If you would like to RESUME with that installation, respond
      'YES' to the following prompt. If you would like to RESTART
      from the beginning, respond 'NO'.
    
      Should the installer resume with the previous installation? Y
    
    If you accidentally respond NO, you can continue by performing the following:
    1. Exit AUTOINST by selecting Option 6.

    2. Reinvoke AUTOINST using the recovery parameter:

        :AUTOINST RECOVERY
    AUTOINST begins to modify the system and displays progress messages.
      Mount the CSLT/STORE tape and put the tape drive online.
      ***** Please stand by *****
      The patched STORE files from the CSLT/STORE tape are being
      restored.
                  .
                  .
                  .
      The STORE files from the CSLT/STORE tape were successfully
      restored.
    
  5. Reply to the tape request.

    The time required to restore the STORE files depends on the number of files to restore, and may take up to 10 minutes (per 2400-foot reel).

    1. AUTOINST automatically streams the installation jobs that complete the installation of most products. The following progress messages are displayed:

        Begin processing installation files.
        Processing n installation files.
        . . . * the number of dots equals n *
      
      The message may indicate zero installation files. This only means that the products you are installing do not require an installation file. AUTOINST continues with the product installation.

    2. When all installation jobs are complete, the following message displays:

        All product installation jobs have been streamed successfully.
    3. When AUTOINST successfully completes its processing, an END OF PROGRAM message displays.

      In addition to streaming installation jobs, AUTOINST removes temporary files that were used during earlier phases of the process.

  6. Dismount the CSLT.

  • Rerunning AUTOINST completed.
    Go to the next section on your checklist.