HPlogo Communicator e3000 MPE/iX Release 7.0 (Software Release C.70.00) > Appendix H Error Messages and Warnings

Warning Messages (INSTWARN)

MPE documents

Complete PDF
Table of Contents
Glossary
Index

1
Message

Warning -- This program cannot install the products listed below. (INSTWARN #1)

Action

The SUBSYS tape has non-AUTOINSTallable products. Install all of these products after updating with the CSLT created by the installer.

2
Message

Expected a YES or NO. (INSTWARN #2)

Action

The input to the prompt is invalid. Respond YES or NO at the prompt.

3
Message

Warning -- The following data communication products may require I/O configuration changes. However, this will not affect the software installation of these products. (INSTWARN #3)

Action

Data communication products exist on the system that may require changes to the system configuration. Consult the appropriate reference manual for that product after installation of the product is complete.

4
Message

Invalid input (INSTWARN #4)

Action

Enter the appropriate number in response to the prompt.

5
Message

Warning -- The installer cannot find enough contiguous disk space on LDEV #1 for UPDATE to update with the CSLT created by the installer. (INSTWARN #5)

Action

Store files to tape, and then purge them. If you have trouble creating this disk space, please contact the Response Center. They can help you identify files with extents on LDEV1.

6
Message

Version mismatch with the old HPINSTFL in the local group. (INSTWARN #6)

Cause

An old HPINSTFL was found and deleted. The installer continues.

Action

No corrective action is required.

7
Message

Corrupt HPINSTFL file (INSTWARN #7)

Cause

A non-ASCII HPINSTFL file was found and purged. The installer continues.

Action

No corrective action is required.

8
Message

Unable to close CD-ROM volume name (INSTWARN #8)

Cause

VSCLOSE failed on a mounted CD-ROM volume.

Action
  • From the console, manually VSCLOSE and dismount the volume. If the drive is a SCSI drive, run AVRSCSI to dismount the volume.

  • Follow the instructions on the screen to continue with the installation.

9
Message

The installer cannot verify that the second CD-ROM volume, volume name, is mounted on LDEV ldev. (INSTWARN #9)

Cause

The user pressed [[return]] at the continue prompt before the second CD-ROM volume was mounted.

Action
  • Follow the instructions on the screen and ensure the second volume has been mounted before pressing [[return]] again to continue.

  • Use DSTAT to verify that the second CD-ROM is mounted.

10
Message

HPINSTAL is terminating on user's request. (INSTWARN #10)

Cause

The user entered QUIT at the prompt to continue after switching the CD-ROM volumes.

Action
  • Mount the first CD-ROM volume again and restart HPINSTAL.

  • HPINSTAL may be started again from the beginning or the current process may be resumed at the point of creating the CSLT.

11
Message

Could not restructure PATCHAUD (INSTWARN #11)

Cause

FCOPY of PATCHAUD to a fixed record format file failed.

Action

If it is necessary to convert the PATCHAUD file to fixed, ASCII then use the following commands:


  : FILE PAUD;REC=-80,,F,ASCII
  : FCOPY FROM=PATCHAUD;TO= PAUD;NEW;SUBSET  Reply Y
  : PURGE PATCHAUD
  : RENAME PAUD,PATCHAUD

Message

12-19 Not used

20
Message

Nonexistent product number. (INSTWARN #20)

Cause

A bad product number was entered.

Action

Reenter the correct product number.

21
Message

Keyword incorrect. Retype your keyword. (INSTWARN #21)

Cause

An invalid keyword was entered.

Action
  • Ensure the key entered matches the keyword certificate received from Hewlett-Packard.

  • Ensure that the product list entered is correct.

  • Run HPINSTAL again from the beginning.

  • Contact the Response Center for further assistance if required.

22
Message

Exactly fourteen (14) characters must be entered. (INSTWARN #22)

Cause

An invalid keyword was entered.

Action
  • Ensure the key entered matches the keyword certificate received from Hewlett-Packard.

  • Ensure that the product list entered is correct.

  • Run HPINSTAL again from the beginning.

  • Contact the Response Center for further assistance if required.

23
Message

23 not used.

24
Message

This product number is not part of the original list. (INSTWARN #24)

Cause

A product number was entered that does not appear in the master product list, PRODLIST.PUB.SYS.

Action

Reenter the product number.

25
Message

At least one encrypted password was found. You will be prompted for the password(s) that are encrypted. (INSTWARN #25)

Action

Some of the passwords needed by the I-files are encrypted. You will be prompted by MPE/iX for the passwords when the jobs are streamed.




Installer Error Messages (INSTERR)


SLTCOPY Messages