- 1
- Message
Warning -- This program cannot install the products listed below.
(INSTWARN #1)
- Action
The SUBSYS tape has non-AUTOINSTallable products. Install all of
these products after updating with the CSLT created by the
installer.
- 2
- Message
Expected a YES or NO. (INSTWARN #2)
- Action
The input to the prompt is invalid. Respond YES or NO at the prompt.
- 3
- Message
Warning -- The following data communication products may require
I/O configuration changes. However, this will not affect the software
installation of these products. (INSTWARN #3)
- Action
Data communication products exist on the system that may require
changes to the system configuration. Consult the appropriate reference
manual for that product after installation of the product is complete.
- 4
- Message
Invalid input (INSTWARN #4)
- Action
Enter the appropriate number in response to the prompt.
- 5
- Message
Warning -- The installer cannot find enough contiguous disk
space on LDEV #1 for UPDATE to update with the CSLT created by the
installer. (INSTWARN #5)
- Action
Store files to tape, and then purge them. If you have trouble
creating this disk space, please contact the Response Center. They can
help you identify files with extents on LDEV1.
- 6
- Message
Version mismatch with the old HPINSTFL in the local group.
(INSTWARN #6)
- Cause
An old HPINSTFL was found and deleted. The installer continues.
- Action
No corrective action is required.
- 7
- Message
Corrupt HPINSTFL file (INSTWARN #7)
- Cause
A non-ASCII HPINSTFL file was found and purged. The installer
continues.
- Action
No corrective action is required.
- 8
- Message
Unable to close CD-ROM volume name (INSTWARN #8)
- Cause
VSCLOSE failed on a mounted CD-ROM volume.
- Action
-
From the console, manually VSCLOSE and dismount the volume. If
the drive is a SCSI drive, run AVRSCSI to dismount the volume.
Follow the instructions on the screen to continue with the
installation.
- 9
- Message
The installer cannot verify that the second CD-ROM volume,
volume name, is mounted on LDEV ldev. (INSTWARN #9)
- Cause
The user pressed [[return]] at the continue prompt before the
second CD-ROM volume was mounted.
- Action
-
- 10
- Message
HPINSTAL is terminating on user's request.
(INSTWARN #10)
- Cause
The user entered QUIT at the prompt to continue after switching
the CD-ROM volumes.
- Action
-
- 11
- Message
Could not restructure PATCHAUD (INSTWARN #11)
- Cause
FCOPY of PATCHAUD to a fixed record format file failed.
- Action
If it is necessary to convert the PATCHAUD file to fixed, ASCII then
use the following commands:
: FILE PAUD;REC=-80,,F,ASCII
: FCOPY FROM=PATCHAUD;TO= PAUD;NEW;SUBSET Reply Y
: PURGE PATCHAUD
: RENAME PAUD,PATCHAUD
- Message
12-19 Not used
- 20
- Message
Nonexistent product number. (INSTWARN #20)
- Cause
A bad product number was entered.
- Action
Reenter the correct product number.
- 21
- Message
Keyword incorrect. Retype your keyword. (INSTWARN #21)
- Cause
An invalid keyword was entered.
- Action
-
Ensure the key entered matches the keyword certificate received
from Hewlett-Packard.
Ensure that the product list entered is correct.
Run HPINSTAL again from the beginning.
Contact the Response Center for further assistance if required.
- 22
- Message
Exactly fourteen (14) characters must be entered.
(INSTWARN #22)
- Cause
An invalid keyword was entered.
- Action
-
Ensure the key entered matches the keyword certificate received
from Hewlett-Packard.
Ensure that the product list entered is correct.
Run HPINSTAL again from the beginning.
Contact the Response Center for further assistance if required.
- 23
- Message
23 not used.
- 24
- Message
This product number is not part of the original list.
(INSTWARN #24)
- Cause
A product number was entered that does not appear in the master
product list, PRODLIST.PUB.SYS.
- Action
Reenter the product number.
- 25
- Message
At least one encrypted password was found. You will be prompted
for the password(s) that are encrypted. (INSTWARN #25)
- Action
Some of the passwords needed by the I-files are encrypted. You will
be prompted by MPE/iX for the passwords when the jobs are streamed.
|