Repairs to the failed component in the data path should be performed as soon as possible to avoid a double failure on the HA array. The more ldevs routed through a single device adapter card, the greater the I/O workload and possible I/O performance degradation.

High availability arrays like the HP XP256 have many redundant subsystems including dual controllers. If an array controller is the source problem for data path failure, the controller can be replaced "hot swapped" while the system and array are online.

Other data path components, such as SCSI bus cabling and device adapter cards, cannot be replaced online and require the system be shut down and powered off for repairs.