HPlogo HP 3000/iX Network Planning and Configuration Guide: HP 3000 MPE/iX Computer Systems > Chapter 10 Validating Network Transport and Cross-Validating with SYSGEN

To Cross-Validate in SYSGEN

» 

Technical documentation

Complete book in PDF
» Feedback

 » Table of Contents

 » Glossary

 » Index

Cross-validation ensures that there are no conflicts in the use of node names, device classes, and physical paths between the data currently contained in NMCONFIG.PUB.SYS and the system configuration data. To cross-validate, use the SYSGEN facility (OP capability is required). To use SYSGEN, type the following commands at the MPE prompt (user input is bold):

sysgen

sysgen> io

io> ld (optional)

io> exit

sysgen> exit

The optional ld (list devices) command allows you to verify the NMMGR devices that are configured.

Cross-validation is done on the KEEP, TAPE, I/O, and RDCC commands in SYSGEN. For more information, see System Startup, Configuration, and Shutdown.

If you have completed the configuration process, proceed to Chapter 14 “Operating the Network”

Feedback to webmaster