HPlogo SNA NRJE Node Manager's Guide: HP 3000 MPE/iX Computer Systems > Chapter 3 SNA NRJE Configuration

Data Required From the Host Configuration

» 

Technical documentation

Complete book in PDF
» Feedback

 » Table of Contents

 » Glossary

 » Index

Data in an NRJE configuration file must correspond to information from the host configuration. Before using NMMGR, you should have certain information from the host configuration.You must coordinate the SNA NRJE configuration with the ACF/NCP, ACF/VTAM, JES2 or JES3, and VSE/POWER host configurations. The HP SNA Products guides explain these configurations. (See the list of related publications in the preface of this manual.) Table 3-1 “AFC/NCP and ACF/VTAM Macro Corresponding Values” shows the relationship between items from the host configuration and items in the NRJE configuration file. To determine whether the value of a host macro must match the value entered in the corresponding NMMGR screen field, see that field's description later in this chapter.

Table 3-1 AFC/NCP and ACF/VTAM Macro Corresponding Values

Host Configuration Macro and Operand

Field in NMMGR Screen

SNA NRJE NMMGR Screen

PU puname

SNAnode Name

Workstation Data

 

Table 3-2 “AFC/NCP and ACF/VTAM Logmode Table” shows the relationship between items from the host configuration and items in the NRJE configuration file.

Table 3-2 AFC/NCP and ACF/VTAM Logmode Table

Host Configuration Logmode Table Macro and Parameter

Field in NMMGR Screen

SNA NRJE NMMGR Screen

MODEENT

LOGMODE

Logmode Identifier

Workstation Data

RUSIZES

Logical Unit RU SizeWorkstation Data

PRIPROT

Compression On

Reader Data

 

Table 3-3 “JES2 Global Parameter Corresponding Values” shows the relationship between items from the host configuration and items in the NRJE configuration file.

Table 3-3 JES2 Global Parameter Corresponding Values

Host Configuration Global Parameter and Subparameter

Field in NMMGR Screen

SNA NRJE NMMGR Screen

&STDFORM

 

Host Standard Print Form Name

Workstation Data Page 2

Host Standard Punch Form Name

Workstation Data Page 2

LOGONn

APPLID

APPLID

Workstation Data

 

NOTE: If you are using JES2 version 1.3.6 (or later) or 2.1.5 (or later), the &STDFORM parameter is different; use the migration tables to determine the correct &STDFORM. For JES2 version 3 (or later), use COMPRESS=YES instead of COMP.

Table 3-4 “JES2 Macro Corresponding Values” shows the relationship between items from the host configuration and items in the NRJE configuration file.

Table 3-4 JES2 Macro Corresponding Values

Host Configuration Macro and Parameter

Field in NMMGR Screen

SNA NRJE NMMGR Screen

LINEnnn

PASSWORD

Line Password

Workstation Data

RMTnnnn

Remote Node Number

Workstation Data

COMP or COMPRESS=YES

Compression On

Reader Data

PASSWORD

Term Password

Workstation Data

BUFSIZE

Logical Unit RU Size

Workstation Data

NUMRD

Number of Readers

Reader Data

Rnnnn.PRm

Writer Name (PRm)

Writer List

 

New Name (PRm)

Writer List

PRWIDTH

MPE configured record size for the default device (SYSDUMP).

none

Rnnnn.PUm

Writer Name (PUm)

Writer List

New Name (PUm)

Writer List

LRECL

MPE configured record size for the default device (SYSDUMP).

none

 

Table 3-5 “JES3 Global Parameter Corresponding Values” shows the relationship between items from the host configuration and items in the NRJE configuration file.

Table 3-5 JES3 Global Parameter Corresponding Values

Host Configuration Global Parameter and Subparameter

Field in NMMGR Screen

SNA NRJE NMMGR Screen

BUFFER

BUFSIZE

Logical Unit RU Size

Workstation Data

OUTSERV

FORMS

Host Standard Print Form Name

Workstation Data Page 2

CDSTOCK

Host Standard Punch Form Name

Workstation Data Page 2

COMMDEFN

APPLID

APPLID

Workstation Data

 

Table 3-6 “JES3 Macro Corresponding Values” shows the relationship between items from the host configuration and items in the NRJE configuration file.

Table 3-6 JES3 Macro Corresponding Values

Host Configuration Macro and Parameter

Field in NMMGR Screen

SNA NRJE NMMGR Screen

RJPWS

P

Line Password

Workstation Data

N

Remote Node Number

Workstation Data

RD

Number of Readers

Reader Data

CONSOLE

JNAME

Remote Node Number

Workstation Data

DEVICE

JNAME

Remote Node Number

Workstation Data

Writer Name (PRm or PUm)

Writer List

New Name (PRm or PUm)

Writer List

 

Table 3-7 “VSE/POWER Macro Corresponding Values” shows the relationship between items from the host configuration and items in the NRJE configuration file.

Table 3-7 VSE/POWER Macro Corresponding Values

Host Configuration Macro and Parameter

Field in NMMGR Screen

SNA NRJE NMMGR Screen

PRMT

REMOTE

Remote Node Number

Workstation Data

PSWRD

Line Password

Workstation Data

 

Feedback to webmaster