HPlogo DTC Device File Access Utilities and Telnet Port Identification: HP 9000 Computers > Appendix A dpp Error Messages

Error Messages Tables

» 

Technical documentation

Complete book in PDF

 » Table of Contents

 » Index

Table A-1 Title not available (Error Messages Tables )

Error Number

Message

Reason

0

dp_file is mandatory

No dp file was found when dpp was started.

1

dp file must be the first argument

The dp file must be specified as the first argument when dpp is started.

2

Cannot read dp file <dp_file>

The dp file mentioned does not exist or cannot be accessed with current access rights.

3

No log file defined (-l option)

The -l option has been detected with no argument.

4

Cannot create log file (-l <log_file>)

The log file cannot be created because of invalid path or insufficient access rights.

5

Cannot access log file (-l <log_file>)

The log file cannot be accessed because of invalid path or insufficient access rights.

6

No ocd file defined in program option

The option -p has been detected with no arguments.

 

Table A-2 Title not available (Error Messages Tables )

Error Number

Message

Reason

7

Cannot execute ocd program (-p <program>

The ocd program does not exist or is not an executable file with correct access rights.

8

Cannot purge device file (/dev/xxx)

The option -k has been selected and the device file exists but cannot be purged because of insufficient access rights.

9

Cannot execute default program (/usr/sbin/ocd)

The ocd program cannot be executed because of insufficient access rights or because it has not been properly installed.

10

Entry ignored (Bad IP address)

The mentioned entry of the dpfile does not have a valid IP address.

11

Entry ignored (No port/board info)

The entry is ignored because board/port information was not mentioned in the dp file.

12

Entry ignored (Bad port number)

The port mentioned in the displayed entry is not either a decimal value, or a string composed of x or X characters.

13

Entry ignored (Bad board number)

The board mentioned in the displayed entry is not a decimal value, or it is not a string composed of x or X characters.

14

No more processes available on system

The ocd program cannot be started because no more processes can be started on the system.

 

Table A-3 Title not available (Error Messages Tables )

Error Number

Message

Reason

15

Entry ignored (No device name)

The device file name has not been configured in the dp file.

16

Entry ignored (Bad device name)

The displayed device file cannot be created because of invalid path or insufficient access rights.

17

Entry ignored (Bad config name)

The displayed configuration file cannot be read because of invalid path or insufficient access rights.

18

Entry ignored (Invalid log level)

The logging level was not set because of invalid values (Must be 0-3).

19

Entry ignored (Bad node name)

The displayed configuration file cannot be read because of invalid node name.

30

Too many login entries (Limited to 2000)

More than 2000 dedicated ports for Telnet Port Identification were specified.

31

Cannot access dpp login file (/var/adm/ dpp_login.bin)

Port Identification feature is disabled due to a dpp login file with insufficient access rights.

50

Device file not specified in /dev/telnet

Many commands (such as ps) may not display the correct device file in their output unless device file is located in /dev/telnet.

99

Unknown error

Error of unknown origin.

 

© 1995 Hewlett-Packard Development Company, L.P.