NFT Logging Location Codes [ NS3000/iX Error Messages Reference Manual ] MPE/iX 5.0 Documentation
NS3000/iX Error Messages Reference Manual
NFT Logging Location Codes
1 CLAS0002 Cause: Attempt to open file NFCAT2 failed.
Logging entry will also contain a file system
error.
Action: Act according to the file system error.
For example, if the error is "non-existent
permanent file", then the system manager should
place a copy of NFCAT2 in NET.SYS.
10 CLAS0002 Cause: Attempt to open file NFTCAT2 failed.
Logging entry will also contain a file system
error.
Action: Act according to the file system error.
For example, if the error is "non-existent
permanent file", then the system manager should
place a copy of NFTCAT2 in NET.SYS.
6 CLAS0003 Cause: NFTCAT2 contains invalid configuration
values.
Action: System manager should obtain a version
of NFTCAT2 that has valid configuration values
and install it in NET.SYS. Another resource is
to change the configuration values in the
existing NFTCAT2 file. However, Hewlett-Packard
does not recommend this procedure. If any other
internal errors (CLAS0000) are logged for the
NFT module of the Network Services subsystem,
see "Submitting an SR" in appendix A of this
manual.
10 CLAS0003 Cause: Incompatible version of NFTCAT2
installed.
Action: System manager should obtain correct
version of NFTCAT2 and install it in NET.SYS.
MPE/iX 5.0 Documentation