LAP-B Link Shutdown Error Messages
This section describes error messages that might occur when you are
shutting down a LAP-B link. These messages appear when a NETCONTROL STOP
command calls the WAN_Kill_Module and encounters an error. They are
displayed on the HP 3000 Series 900 operator's console inq the following
format:
WAN KILL MODULE (linkname) Message text
WAN KILL MODULE (linkname) Error ErrorNum, Status = Status, Path:
PhysPath
51 MESSAGE Could not stop trace.
CAUSE Trace may have been turned off via the
LINKCONTROL command, but the link software
status indicates that it was on.
ACTION Ignore this problem unless you are experiencing
other problems. Otherwise record the error
information printed on the console and contact
your Hewlett-Packard representative.
52 MESSAGE The link is not in the link table.
CAUSE The link specified is not active.
ACTION If the link name is incorrect, issue the command
again with the correct linkname. If the link
name is correct, the link has already been
shutdown and no action is necessary.
53 MESSAGE The link type is not SDLC, LAP-B, or RJE.
CAUSE The caller of this module did not set the link
type to one of SDLC, LAP-B, or RJE.
ACTION Please record the error information printed on
the console and contact your Hewlett-Packard
representative.
54 MESSAGE Could not delete the link from the link table.
CAUSE The link name specified is not in the link
table.
ACTION Check that the link name is correct and try
again. The link may have already been shutdown.
55 MESSAGE Could not unconfigure the link from the system.
CAUSE The I/O subsystem does not have any record of
this link being active.
ACTION Check that the link name is correct and try
again. The link may have already been shutdown.
56 MESSAGE Could not delete the auxiliary buffer pool.
CAUSE There are many reasons why this could happen.
The status indicator provides more detailed
information as to the specific cause of the
problem.
ACTION Please record the error information printed on
the console and contact your Hewlett-Packard
representative.
57 MESSAGE Could not determine the PSI path number IO Serv.
CAUSE The I/O subsystem does not have a physical path
for the link that was specified and therefore
cannot deconfigure it from the system.
ACTION Check that the link name is correct and try
again.
MPE/iX 5.0 Documentation