HP 3000 Manuals

LAP-B Link Shutdown Error Messages [ NS3000/iX Error Messages Reference Manual ] MPE/iX 5.0 Documentation


NS3000/iX Error Messages Reference Manual

LAP-B Link Shutdown Error Messages 

This section describes error messages that might occur when you are
shutting down a LAP-B link.  These messages appear when a NETCONTROL STOP
command calls the WAN_Kill_Module and encounters an error.  They are
displayed on the HP 3000 Series 900 operator's console inq the following
format:

WAN KILL MODULE (linkname) Message text

WAN KILL MODULE (linkname) Error ErrorNum, Status = Status, Path:
PhysPath

51           MESSAGE      Could not stop trace.

             CAUSE        Trace may have been turned off via the
                          LINKCONTROL command, but the link software
                          status indicates that it was on.

             ACTION       Ignore this problem unless you are experiencing
                          other problems.  Otherwise record the error
                          information printed on the console and contact
                          your Hewlett-Packard representative.

52           MESSAGE      The link is not in the link table.

             CAUSE        The link specified is not active.

             ACTION       If the link name is incorrect, issue the command
                          again with the correct linkname.  If the link
                          name is correct, the link has already been
                          shutdown and no action is necessary.

53           MESSAGE      The link type is not SDLC, LAP-B, or RJE.

             CAUSE        The caller of this module did not set the link
                          type to one of SDLC, LAP-B, or RJE.

             ACTION       Please record the error information printed on
                          the console and contact your Hewlett-Packard
                          representative.

54           MESSAGE      Could not delete the link from the link table.

             CAUSE        The link name specified is not in the link
                          table.

             ACTION       Check that the link name is correct and try
                          again.  The link may have already been shutdown.

55           MESSAGE      Could not unconfigure the link from the system.

             CAUSE        The I/O subsystem does not have any record of
                          this link being active.

             ACTION       Check that the link name is correct and try
                          again.  The link may have already been shutdown.

56           MESSAGE      Could not delete the auxiliary buffer pool.

             CAUSE        There are many reasons why this could happen.
                          The status indicator provides more detailed
                          information as to the specific cause of the
                          problem.

             ACTION       Please record the error information printed on
                          the console and contact your Hewlett-Packard
                          representative.

57           MESSAGE      Could not determine the PSI path number IO Serv.

             CAUSE        The I/O subsystem does not have a physical path
                          for the link that was specified and therefore
                          cannot deconfigure it from the system.

             ACTION       Check that the link name is correct and try
                          again.



MPE/iX 5.0 Documentation