Server Messages [ HP VPLUS/Windows Programmer's Guide ] MPE/iX 5.0 Documentation
HP VPLUS/Windows Programmer's Guide
Server Messages
5004
Message PC Network not loaded. (VW5004)
Cause You have not loaded the PC networking software.
Action Exit the VPLUS/Windows presentation server and Microsoft
Windows. Load the networking software and restart.
-------------------
5005
Message Internal error - invalid socket type. Please report.
(VW5005)
Cause This error should not normally occur and is intended
only for HP internal use. However, abnormal
environmental hardware or software problems can generate
this error.
Action Reboot your PC and reload the PC networking software.
If the problem persists after rebooting the PC more than
once, warmstart the HP 3000 and restart the LAN. If the
problem still occurs, check the PC and LAN hardware.
Continuance of this problem indicates abnormal hardware
or software. Note the error number and contact your
Hewlett-Packard support representative.
-------------------
5006
Message Internal error - invalid protocol. Please report.
(VW5006)
Cause See error message 5005 for cause information.
Action See error message 5005 for action information.
-------------------
5009
Message Internal error - protocol not active. Please report.
(VW5009)
Cause See error message 5005 for cause information.
Action See error message 5005 for action information.
-------------------
5011
Message Insufficient memory for networking. (VW5011)
Cause Insufficient memory was allocated for the PC networking
software.
Action Run USRCONFG to configure additional circuits.
VPLUS/Windows requires one circuit per application
connection to the HP 3000. Refer to "Configuring
Communications Circuits" in Appendix B for information
about configuring the additional circuits.
-------------------
5014
Message Internal error - invalid address. Please report.
(VW5014)
Cause See error message 5005 for cause information.
Action See error message 5005 for action information.
-------------------
5018
Message Internal error - InitOpt, AddOpt syntax error. Please
report. (VW5018)
Cause See error message 5005 for cause information.
Action See error message 5005 for action information.
-------------------
5028
Message Internal error - invalid node name length. Please
report. (VW5028)
Cause See error message 5005 for cause information.
Action See error message 5005 for action information.
-------------------
5029
Message Internal error - invalid socket descriptor. Please
report. (VW5029)
Cause See error message 5005 for cause information.
Action See error message 5005 for action information.
-------------------
5037
Message Cannot find HP 3000 host node. (VW5037)
Cause The host computer is down or is not on the network.
Action Contact your system manager to determine if the host
computer is up and running on the network. Also, check
the host name in the application definition.
-------------------
5038
Message Internal error - process does not own the descriptor.
Please report. (VW5038)
Cause See error message 5005 for cause information.
Action See error message 5005 for action information.
-------------------
5039
Message Internal error - incorrect node name syntax. Please
report. (VW5039)
Cause See error message 5005 for cause information.
Action See error message 5005 for action information.
-------------------
5050
Message Internal error - incorrect data length. Please report.
(VW5050)
Cause See error message 5005 for cause information.
Action See error message 5005 for action information.
-------------------
5051
Message Internal error - destination socket descriptor not
valid. Please report. (VW5051)
Cause See error message 5005 for cause information.
Action See error message 5005 for action information.
-------------------
5054
Message Internal error - source socket descriptor not valid.
Please report. (VW5054)
Cause See error message 5005 for cause information.
Action See error message 5005 for action information.
-------------------
5057
Message Internal error - too many nowait sends. Please report.
(VW5057)
Cause See error message 5005 for cause information.
Action See error message 5005 for action information.
-------------------
5058
Message Internal error - too many nowait receives. Please
report. (VW5058)
Cause See error message 5005 for cause information.
Action See error message 5005 for action information.
-------------------
5059
Message Internal error - connection timed out waiting for
completion. Please report. (VW5059)
Cause The HP 3000 was unable to send data back to the PC, or
the logon was not completed.
Action This error message appears if your PC is on a different
subnet than the HP 3000. Ask your system manager to add
the name and address of your PC to the HP 3000 network
directory.
If this action does not resolve your problem, reboot
your PC and reload the PC networking software. If the
problem persists, note the error number and contact your
Hewlett-Packard support representative.
-------------------
5062
Message Internal error - connection pending. Please report.
(VW5062)
Cause See error message 5005 for cause information.
Action See error message 5005 for action information.
-------------------
5065
Message Connection terminated by remote host computer. (VW5065)
Cause An application termination or connection time-out
terminated the connection to the host computer.
Action Contact your system manager if you did not expect
termination of the application.
-------------------
5066
Message Internal error - connection socket descriptor not valid.
Please report. (VW5066)
Cause See error message 5005 for cause information.
Action See error message 5005 for action information.
-------------------
5074
Message Internal error - invalid control request. Please report.
(VW5074)
Cause See error message 5005 for cause information.
Action See error message 5005 for action information.
-------------------
5076
Message Internal error - timeout value invalid. Please report.
(VW5076)
Cause See error message 5005 for cause information.
Action See error message 5005 for action information.
-------------------
5111
Message Internal error - NetIPC internal error. Please report.
(VW5111)
Cause See error message 5005 for cause information.
Action See error message 5005 for action information.
-------------------
5117
Message Connect request to host computer failed. Please report.
(VW5117)
Cause See error message 5005 for cause information.
Action See error message 5005 for action information.
-------------------
5118
Message Incompatible PC networking. (VW5118)
Cause The PC network transport is incompatible with the NetIPC
library. The transport must be version 6 or later.
Action Contact your system manager to install the correct
version of the transport.
-------------------
5121
Message Internal error - IPCWait timed out. Please report.
(VW5121)
Cause See error message 5005 for cause information.
Action See error message 5005 for action information.
-------------------
5124
Message Internal error - invalid option entry number. Please
report. (VW5124)
Cause See error message 5005 for cause information.
Action See error message 5005 for action information.
-------------------
5153
Message Internal error - socket already in use. Please report.
(VW5153)
Cause See error message 5005 for cause information.
Action See error message 5005 for action information.
-------------------
5154
Message Internal error - no outstanding I/O for IPCWait. Please
report (VW5154)
Cause See error message 5005 for cause information.
Action See error message 5005 for action information.
-------------------
6001
Message PC network down. (VW6001)
Cause Either the local network is down or the network software
connection has been disconnected.
Action Reboot your PC and reload the network.
-------------------
6002
Message Internal error - invalid program name length. Please
report. (VW6002)
Cause See error message 5005 for cause information.
Action See error message 5005 for action information.
-------------------
6003
Message Internal error - invalid flag. Please report. (VW6003)
Cause See error message 5005 for cause information.
Action See error message 5005 for action information.
-------------------
6004
Message Internal error - invalid option. Please report.
(VW6004)
Cause See error message 5005 for cause information.
Action See error message 5005 for action information.
-------------------
6005
Message Internal error - invalid option format. Please report.
(VW6005)
Cause See error message 5005 for cause information.
Action See error message 5005 for action information.
-------------------
6006
Message Unable to log on to host computer. (VW6006)
Cause Either the application logon information is incorrect,
or the system is currently inaccessible.
Action Check the user names, group names, account names, and
associated passwords in the application definition.
(For MPE XL, this error also occurs if a user supplies a
password when no password has been defined.) Also check
the session limit or the JOBFENCE.
-------------------
6007
Message Cannot find the VPLUS/Windows Application Server on host
computer. (VW6007)
Cause The required VPLUS/Windows application server (VWAPPSER)
is not installed on the HP 3000 host computer
Action Contact your system manager to verify that VPLUS/Windows
is installed on the host computer.
-------------------
6008
Message Internal error - invalid remote program descriptor.
Please report. (VW6008)
Cause See error message 5005 for cause information.
Action See error message 5005 for action information.
-------------------
6009
Message Host process limit reached. (VW6009)
Cause The number of processes on the host computer exceeded
the allowable maximum number.
Action Either wait to run your application until the computer
is not as busy, or contact your system manager to adjust
resource utilization on the host computer.
-------------------
6010
Message Host computer does not have enough memory. (VW6010)
Cause The HP 3000 host computer does not have enough memory to
run the networking software.
Action Contact your system manager to adjust resource
utilization on the host computer.
-------------------
6011
Message Cannot run the VPLUS/Windows Application Server on host
computer. (VW6011)
Cause The VPLUS/Windows application server exists but cannot
be started.
Action Contact your system manager to determine causes
that prevented starting the application server.
(VWAPPSER.PUB.SYS).
-------------------
6012
Message Internal error - RPM internal error. Please report.
(VW6012)
Cause See error message 5005 for cause information.
Action See error message 5005 for action information.
-------------------
6013
Message RPM server not running or data corruption. Please
report. (VW6013)
Cause The transport is not functioning properly, or the RPM
server is not running on the host computer.
Action Contact your system manager. Check the RPM server on
the host computer, or run PC/host data communications
diagnostics.
-------------------
6014
Message Internal error - network error. Please report. (VW6014)
Cause This error should not normally occur and is intended
only for HP internal use. However, abnormal
environmental hardware or software problems can generate
this error.
Action Check the host name in the application options.
Check for any logon UDC prompts for the HP 3000 logon by
logging on via a terminal or emulator. If any prompts
exist, change the logon process to eliminate them.
If the above actions do not resolve the problem, reboot
your PC and reload the PC networking software. If the
problem persists after rebooting the PC more than once,
warmstart the HP 3000 and restart the LAN. If the
problem still occurs, check the PC and LAN hardware.
Continuance of this problem indicates abnormal hardware
or software. Note the error number and contact your
Hewlett-Packard support representative.
-------------------
6015
Message Incompatible PC or HP 3000 networking. (VW6015)
Cause The versions of RPM software on the local and remote
computers are incompatible.
Action Contact your system manager to install the correct
version of the networking software.
-------------------
6016
Message Internal error - option not supported by remote RPM
server. Please report. (VW6016)
Cause See error message 5005 for cause information.
Action See error message 5005 for action information.
-------------------
6017
Message Internal error - send or receive length invalid. Please
report. (VW6017)
Cause See error message 5005 for cause information.
Action See error message 5005 for action information.
-------------------
6018
Message Internal error - option data not valid. Please report.
(VW6018)
Cause See error message 5005 for cause information.
Action See error message 5005 for action information.
-------------------
6019
Message HP 3000 host node not found. (VW6019)
Cause The host computer is down or is not on the network.
Action Contact your system manager to determine if the host
computer is up and running on the network. Also, check
the host name in the application definition.
-------------------
6022
Message Process terminated on remote host computer. (VW6022)
Cause The application process on the host computer has been
terminated.
Action Contact your system manager if the application
termination is abnormal.
-------------------
6023
Message Internal error - unsupported intrinsic. Please report.
(VW6023)
Cause See error message 5005 for cause information.
Action See error message 5005 for action information.
-------------------
6104
Message Internal error - RPM required parameter omitted. Please
report. (VW6104)
Cause See error message 5005 for cause information.
Action See error message 5005 for action information.
-------------------
6106
Message Incompatible HP 3000 host networking software. Please
report. (VW6106)
Cause An incompatible version of network services on the host
computer caused this problem.
Action Contact your system manager to install the correct
version of network services.
-------------------
6107
Message Timeout occurred during HP 3000 logon - try again later.
(VW6107)
Cause The time allowed for logging on has expired.
Action Try again later or contact your system manager.
-------------------
6109
Message Host computer busy - try again later. (VW6109)
Cause The host computer was unable to process the logon
request because it was busy.
Action Try again later or contact your system manager.
-------------------
6111
Message Remote process management (RPM) software startup failed.
Please report. (VW6111)
Cause VPLUS/Windows could not start the RPMDAD process on the
host computer for an unknown reason.
Action Contact your system manager to determine causes that
prevented RPM startup.
-------------------
6113
Message Internal error - invalid control state. Please report.
(VW6113)
Cause See error message 5005 for cause information.
Action See error message 5005 for action information.
-------------------
6700
Message Internal error - RPMWait timed out. Please report.
(VW6700)
Cause See error message 5005 for cause information.
Action See error message 5005 for action information.
-------------------
6701
Message Internal error - invalid RPM call. Please report.
(VW6701)
Cause See error message 5005 for cause information.
Action See error message 5005 for action information.
-------------------
6703
Message Internal error - invalid program descriptor. Please
report. (VW6703)
Cause See error message 5005 for cause information.
Action See error message 5005 for action information.
-------------------
6704
Message Internal error - invalid RPM buffer. Please report.
(VW6704)
Cause See error message 5005 for cause information.
Action See error message 5005 for action information.
-------------------
6705
Message Internal error - invalid buffer length. Please report.
(VW6705)
Cause See error message 5005 for cause information.
Action See error message 5005 for action information.
-------------------
6709
Message Internal error - invalid node name length. Please
report. (VW6709)
Cause See error message 5005 for cause information.
Action See error message 5005 for action information.
-------------------
6710
Message Internal error - invalid logon length. Please report.
(VW6710)
Cause See error message 5005 for cause information.
Action See error message 5005 for action information.
-------------------
6711
Message Internal error - invalid password length. Please report.
(VW6711)
Cause See error message 5005 for cause information.
Action See error message 5005 for action information.
-------------------
6712
Message Internal error - invalid timeout value. Please report.
(VW6712)
Cause See error message 5005 for cause information.
Action See error message 5005 for action information.
-------------------
6713
Message Internal error - invalid control data length. Please
report. (VW6713)
Cause See error message 5005 for cause information.
Action See error message 5005 for action information.
-------------------
6714
Message Internal error - invalid hangup force. Please report.
(VW6714)
Cause See error message 5005 for cause information.
Action See error message 5005 for action information.
-------------------
6717
Message Internal error - invalid request data length. Please
report. (VW6717)
Cause See error message 5005 for cause information.
Action See error message 5005 for action information.
-------------------
7050
Message Could not open PC forms file <forms file name>.
(VW7050)
Cause VPLUS/Windows could not locate the PC forms file that
the HP 3000 application specified.
Action Note the forms file name and contact your system
manager.
-------------------
7054
Message This PC forms file's version does not match the HP 3000
forms file version. (VW7054)
Cause The compile time stamp of the HP 3000 forms file differs
from the time stamp of the PC forms file.
Action Contact your system manager to synchronize the host and
PC forms files.
-------------------
7500
Message HP 3000 application setup failed. (VW7500) - <ASF
command>
Cause Execution of a command in the Application Support File
failed.
Action Note the ASF command displayed after the error message.
Check the Application Support File for invalid command
syntax or environmental factors that might have caused
the command failure.
-------------------
7501
Message HP 3000 application program creation failed. (VW7501)
Cause The VPLUS/Windows application server could not start the
specified HP 3000 application.
Action Check the program name of the application in the
definition. If the program name is correct, HP 3000
environmental problems might have prevented the program
from starting. Check HP 3000 system resources.
-------------------
7502
Message HP 3000 application program activation failed. (VW7502)
Cause The VPLUS/Windows application server created the HP 3000
application process, but was unable to activate the
application.
Action Check HP 3000 system resources.
-------------------
9001
Message There is no room for a new application in the
configuration file. (VW9001)
Cause The configuration file can contain only 50 applications.
Action Delete a less frequently used application before adding
a new one, or create a new configuration file. The
presentation server creates a new configuration file if
you have deleted or renamed VWSERVW.CFG.
-------------------
9002
Message Cannot find the specified application in the
configuration file. (VW9002)
Cause The specified application does not exist in the
configuration file.
Action Check the application name entered for a spelling error.
-------------------
9006
Message The name selection cannot be blank. (VW9006)
Cause The Application Name field is empty.
Action Select an application from the application list, or type
in an application name.
-------------------
9007
Message Cannot save the configuration file. (VW9007)
Cause The presentation server encountered an unknown error
when attempting to save the configuration file.
Action Check whether sufficient disk space remains to save the
configuration file.
-------------------
9009
Message Cannot find the specified color in the configuration
file. (VW9009)
Cause The specified color does not exist in the configuration
file.
Action Check the spelling of the color name.
-------------------
9010
Message There is no room for a new color pair in the
configuration file. (VW9010)
Cause The configuration file can only contain 50 color pairs.
Action Delete less frequently used color pairs before adding
new ones.
-------------------
9011
Message The prefix VW is reserved for VPLUS/Windows color pairs.
(VW9011)
Cause Color pairs with the VW prefix are reserved and cannot
be altered.
Action Create your own color pairs with names beginning with
any string other than VW.
-------------------
9012
Message This color is currently in use and cannot be deleted.
(VW9012)
Cause The specified color pair is currently mapped to an
enhancement; therefore, you cannot delete it.
Action Unmap the color pair before deleting it.
-------------------
9013
Message Configuration file not found. Create a new one? (VW9013)
Cause The configuration file VWSERVW.CFG does not exist in the
current directory.
Action Click OK to create a new configuration file. Click
Cancel if you do not want to create a new configuration
file.
-------------------
9014
Message Not enough memory. (VW9014)
Cause You cannot start the application because of insufficient
memory.
Action Close some applications to free up space for starting
new applications.
-------------------
MPE/iX 5.0 Documentation