HP 3000 Manuals

NMERR Messages (contd.) [ Using the Node Management Services (NMS) Utilities ] MPE/iX 5.0 Documentation


Using the Node Management Services (NMS) Utilities

NMERR Messages (contd.) 

NMERR 101    MESSAGE      Fix levels differ in one or more modules.
                          (NMERR 101)

             CAUSE        There is a version mismatch between the various
                          modules of the subsystem.  Incorrect
                          installation of the subsystem software.

             ACTION       See "Invalid Software Installation" at the
                          beginning of this appendix.

--------------------------------------------------------------------------

NMERR 102    MESSAGE      Update levels differ in one or more modules.
                          (NMERR 102)

             CAUSE        There is a version mismatch between the various
                          modules of the subsystem.  Incorrect
                          installation of the subsystem software.

             ACTION       See "Invalid Software Installation" at the
                          beginning of this appendix.

--------------------------------------------------------------------------

NMERR 103    MESSAGE      Version levels differ in one or more modules.
                          (NMERR 103)

             CAUSE        There is a version mismatch between the various
                          modules of the subsystem.  Incorrect
                          installation of the subsystem.

             ACTION       See "Invalid Software Installation" at the
                          beginning of this appendix.

--------------------------------------------------------------------------

NMERR 104    MESSAGE      One or more subsystem modules are missing.
                          (NMERR 104)

             CAUSE        A module required for normal operation of the
                          subsystem is missing.

             ACTION       See "Invalid Software Installation" at the
                          beginning of this appendix.

--------------------------------------------------------------------------

NMERR 105    MESSAGE      One or more subsystem modules are invalid.
                          (NMERR 105)

             CAUSE        An error has occurred trying to read the version
                          ID of one or more of the subsystem's modules.
                          An I/O error, disc error, or similar has
                          prevented reading the version stamp correctly.

             ACTION       Correct this problem and retry.  If necessary
                          see "Invalid Software Installation" at the
                          beginning of this appendix.

             CAUSE        Some of the program files and data files have
                          the version stamp located in the last user label
                          record.  Perhaps the file was copied without
                          copying its user label records properly.

             ACTION       See "Invalid Software Installation" at the
                          beginning of this appendix.

--------------------------------------------------------------------------

NMERR 106    MESSAGE      MODULE FLAGS parameter invalid.

             CAUSE        The MODULE FLAGS MODE field (bits 7:6) is not in
                          the range 0 to 5, or the TYPE field (bits 13:3)
                          is not in the range 0 to 2.  Returned by
                          NMSUBSYSVERS, SUBSYSOVERS, and other subsystem
                          level 2 version check procedures.  Probable
                          internal error by caller.

             ACTION       See "Submitting an SR" at the beginning of this
                          appendix.

--------------------------------------------------------------------------

NMERR 107    MESSAGE      FLAGS options are incompatible.

             CAUSE        Some mutually incompatible option bits were set
                          in the FLAGS parameter.  Returned by
                          NMSUBSYSVERS, SUBSYSOVERS, and other subsystem
                          level 2 version check procedures.

             ACTION       See "Submitting an SR" at the beginning of this
                          appendix.

--------------------------------------------------------------------------

NMERR 130    MESSAGE      Unable to create the link manager process.
                          (NMERR 130)

             CAUSE        A non-zero result code was returned by
                          NMMONSTARTREQ to NMOPENLINK.

                          Returned by NMOPENLINK. Loader error trying to
                          load LINKMGR.PUB.SYS program file.

             ACTION       Try to ALLOCATE LINKMGR.PUB.SYS. If this fails,
                          correct the problem according to the error
                          messages given.  If this succeeds, retry the
                          action that led to the problem.  If this error
                          occurs again, this is not the problem.

             CAUSE        Out of MPE resources.

             ACTION       See "Insufficient MPE Resources" at the
                          beginning of this appendix.

             CAUSE        A non-zero result code was returned by
                          NMMONSTARTREQ to NMOPENLINK. Returned by
                          NMOPENLINK. Internal error.

             ACTION       See "Submitting an SR" at the beginning of this
                          appendix.

--------------------------------------------------------------------------

NMERR 131    MESSAGE      Invalid item detected in configuration record.
                          (NMERR 131)

             CAUSE        Error reading and/or interpreting data from
                          configuration file.  Returned by NMOPENLINK.

             ACTION       See "Corrupt Configuration File" at the
                          beginning of this appendix.

--------------------------------------------------------------------------

NMERR 132    MESSAGE      Link in exclusive use by another subsystem.
                          (NMERR 132)

             CAUSE        Link has already been opened by another process.
                          Returned by NMOPENLINK. Another process has this
                          link opened.

             ACTION       Shut down the other process to free the link.

             CAUSE        A LINKMGR process which had this link previously
                          did not close it when expected.  This is an
                          internal error.

             ACTION       See "Submitting an SR" at the beginning of this
                          appendix.  If possible, include a memory dump
                          with the SR.

--------------------------------------------------------------------------

NMERR 133    MESSAGE      Start param length error in Link Manager.
                          (NMERR 133)

             CAUSE        Either a software version mismatch, or an
                          internal error.

             ACTION       See "Submitting an SR" at the beginning of this
                          appendix.

--------------------------------------------------------------------------

NMERR 134    MESSAGE      A successful NMOPENLINK for this link must occur
                          before executing this function.  (NMERR 134)

             CAUSE        NMOPENLINK has not yet been called successfully.
                          Returned by NMCLOSELINK, NMMANAGELINK,
                          NMLINKINFO, and NMLINKDIAL. This is usually an
                          internal error in the calling subsystem.

             ACTION       See "Submitting an SR" at the beginning of this
                          appendix.

--------------------------------------------------------------------------

NMERR 135    MESSAGE      Required items missing in configuration record.
                          (NMERR 135)

             CAUSE        Error reading data from configuration file.
                          Returned by NMOPENLINK. Configuration file is
                          not valid.

             ACTION       See "Corrupt Configuration File" at the
                          beginning of this appendix.

--------------------------------------------------------------------------

NMERR 136    MESSAGE      Parameter information exceeds permissible
                          length.  (NMERR 136)

             CAUSE        Information buffer given by caller exceeds 128
                          words in length.  Returned by NMMANAGELINK and
                          NMLINKDIAL. This is usually an internal error in
                          the calling subsystem.

             ACTION       See "Submitting an SR" at the beginning of this
                          appendix.

--------------------------------------------------------------------------

NMERR 137    MESSAGE      A successful NMOPENLINK for this link must occur
                          before executing this function.  (NMERR 137)

             CAUSE        NMOPENLINK has not been executed successfully
                          for this link.  Returned by NMCLOSELINK,
                          NMMANAGELINK, NMLINKINFO and NMLINKDIAL This is
                          usually an internal error in the calling
                          subsystem.

             ACTION       See "Submitting an SR" at the beginning of this
                          appendix.

--------------------------------------------------------------------------

NNMERR 138   MESSAGE      Unable to find DC/LDM in system I/O tables.
                          (NMERR 138)

             CAUSE        The NSLINK ldev was not configured for the link
                          in NMCONFIG.PUB.SYS when the system was started.

             ACTION       Ensure the NSLINK ldev is configured for the
                          link used by NS, and re-boot.  More information
                          may be found in the NMLG log file.

--------------------------------------------------------------------------

NMERR 139    MESSAGE      Unable to find the specified linkname in system
                          I/O tables.  (NMERR 139)

             CAUSE        The specified linkname is not configured in the
                          LINK subtree of the configuration file.

             ACTION       Check that the linkname specified to the
                          subsystem has a matching linkname configured
                          under the LINK configuration subtree.

--------------------------------------------------------------------------

NMERR 142    MESSAGE      Status request to communication board failed.
                          (NMERR 142)

             CAUSE        Call to procedure TRAN'GETINFO failed.  Returned
                          by NMLINKINFO and LINKCONTROL. Bad software
                          installation.

             ACTION       Make sure that the versions of NMS software and
                          port translator software are compatible.  See
                          "Invalid Software Installation" at the beginning
                          of this appendix.

             CAUSE        An internal error occurred.

             ACTION       See "Submitting an SR" at the beginning of this
                          appendix.

--------------------------------------------------------------------------

NMERR 146    MESSAGE      User specified buffer inadequate for request.
                          (NMERR 146)

             CAUSE        Caller did not supply a buffer large enough for
                          returned data.  Returned by NMLINKINFO. Bad
                          software installation.

             ACTION       Make sure that the versions of NMS software and
                          port translator software are compatible.  See
                          "Invalid Software Installation" at the beginning
                          of this appendix.

             CAUSE        An internal error occurred.

             ACTION       See "Submitting an SR" at the beginning of this
                          appendix.

--------------------------------------------------------------------------

NMERR 147    MESSAGE      Link manager buffer area inadequate for request.
                          (NMERR 147)

             CAUSE        Link Manager's internal buffer is not large
                          enough to handle this request.  Returned by
                          NMLINKINFO. Bad software installation.

             ACTION       Make sure that the versions of NMS software and
                          port translator software are compatible.  See
                          "Invalid Software Installation" at the beginning
                          of this appendix.

             CAUSE        An internal error occurred.

             ACTION       See "Submitting an SR" at the beginning of this
                          appendix.

--------------------------------------------------------------------------

NMERR 148    MESSAGE      Specified item code is out of range.  (NMERR
                          148)

             CAUSE        No information item corresponds to the given
                          item code.  Returned by NMLINKINFO. Bad software
                          installation.

             ACTION       Make sure that the versions of NMS software and
                          port translator software are compatible.  See
                          "Invalid Software Installation" at the beginning
                          of this appendix.

             CAUSE        An internal error occurred.

             ACTION       See "Submitting an SR" at the beginning of this
                          appendix.

--------------------------------------------------------------------------

NMERR 149    MESSAGE      Dial request to communications board failed.
                          (NMERR 149)

             CAUSE        Error calling procedure TRAN'CONFIGDIAL.
                          Returned by NMLINKDIAL. Bad software
                          installation.

             ACTION       Make sure that the versions of NMS software and
                          port translator software are compatible.  See
                          "Invalid Software Installation" at the beginning
                          of this appendix.

             CAUSE        An internal error occurred.

             ACTION       See "Submitting an SR" at the beginning of this
                          appendix.

--------------------------------------------------------------------------

NMERR 154    MESSAGE      Dial facility is not supported.  (NMERR 154)

             CAUSE        Call to LINKDIALREQ failed.  Returned by
                          NMLINKDIAL. Bad software installation.

             ACTION       Make sure that the versions of NMS software and
                          port translator software are compatible.  See
                          "Invalid Software Installation" at the beginning
                          of this appendix.

             CAUSE        An internal error occurred.

             ACTION       See "Submitting an SR" at the beginning of this
                          appendix.

--------------------------------------------------------------------------

NMERR 155    MESSAGE      Multicast address downloading is not supported.
                          (NMERR 155)

             CAUSE        Call to NMLINKDOWNMC is not supported.  Bad
                          software installation.

             ACTION       Make sure that the versions of NMS software and
                          port translator software are compatible.  See
                          "Invalid Software Installation" at the beginning
                          of this appendix.

             CAUSE        An internal error occurred.

             ACTION       See "Submitting an SR" at the beginning of this
                          appendix.

--------------------------------------------------------------------------

NMERR 156    MESSAGE      This NMLINK intrinsic is not supported under
                          HPE. (NMERR 156)

             CAUSE        Bad software installation.

             ACTION       Make sure that the versions of NMS software and
                          port translator software are compatible.  See
                          "Invalid Software Installation" at the beginning
                          of this appendix.

             CAUSE        An internal error occurred.

             ACTION       See "Submitting an SR" at the beginning of this
                          appendix.

--------------------------------------------------------------------------

NMERR 157    MESSAGE      DS/LDM open request failed.  (NMERR 157)

             CAUSE        The request to open the DC/LDM failed.  Returned
                          by NMOPENLINK. Bad software installation.

             ACTION       Make sure that the versions of NMS software and
                          port translator software are compatible.  See
                          "Invalid Software Installation" at the beginning
                          of this appendix.

             CAUSE        An internal error occurred.

             ACTION       See "Submitting an SR" at the beginning of this
                          appendix.

--------------------------------------------------------------------------

NMMER 158    MESSAGE      DS/LDM close request failed.  (NMERR 158)

             CAUSE        The request to close the DC/LDM failed.
                          Returned by NMCLOSELINK. Bad software
                          installation.

             ACTION       Make sure that the versions of NMS software and
                          port translator software are compatible.  See
                          "Invalid Software Installation" at the beginning
                          of this appendix.

             CAUSE        An internal error occurred.

             ACTION       See "Submitting an SR" at the beginning of this
                          appendix.

--------------------------------------------------------------------------

NMERR 159    MESSAGE      Unable to allocate device.  (NMERR 159)

             CAUSE        Either the ldev does not exist, or is the wrong
                          type or subtype, or some other problem caused
                          ALLOCATE or GETDEVINFO to fail.  Returned by
                          NMOPENLINK .

             ACTION       Check NM log entry.  If status is betwen -3 and
                          10, the status is from ALLOCATE. If it is
                          between 99 and 103, this is GETDEVINFO. If the
                          status is 200, the ldev is the wrong type or
                          subtype for NMOPENLINK. Also, check that the
                          ldev is correctly configured and is available.

--------------------------------------------------------------------------

NMERR 160    MESSAGE      Number of parameters exceeds maximum of 20.
                          (NMERR 160)

             CAUSE        Returned after entering LINKCONTROL command
                          incorrectly.

             ACTION       Check the parameters against the LINKCONTROL
                          syntax.  Try again.

--------------------------------------------------------------------------

NMERR 161    MESSAGE      Expects link name parameter.  (NMERR 161)

             CAUSE        Returned after entering LINKCONTROL command
                          incorrectly.

             ACTION       Specify the link name parameter and try again.

--------------------------------------------------------------------------

NMERR 162    MESSAGE      Expects a name from one to eight characters
                          long.  (NMERR 162)

             CAUSE        Returned after entering LINKCONTROL command
                          incorrectly.

             ACTION       Check the spelling and try again.

--------------------------------------------------------------------------

NMERR 163    MESSAGE      Expects alphanumeric name starting with
                          alphabetic.  (NMERR 163)

             CAUSE        Returned after entering LINKCONTROL command
                          incorrectly.

             ACTION       Check the spelling and try again.

NMERR 164    MESSAGE      Expects a semicolon after link name parameter.
                          (NMERR 164)

             CAUSE        Returned after entering LINKCONTROL command
                          incorrectly.

             ACTION       Correct and try again.
--------------------------------------------------------------------------

NMERR 165    MESSAGE      Expects TRACE keyword.  (NMERR 165)

             CAUSE        Returned after entering LINKCONTROL command
                          incorrectly.

             ACTION       Specify keyword and try again.

--------------------------------------------------------------------------

NMERR 166    MESSAGE      Expects an equals sign after TRACE keyword.
                          (NMERR 166)

             CAUSE        Returned after entering LINKCONTROL command
                          incorrectly.

             ACTION       Correct and try again.

--------------------------------------------------------------------------

NMERR 171    MESSAGE      Specified linkname is not an active datacomm
                          device.  (NMERR 171)

             CAUSE        The specified linkname does not exist.

             ACTION       Check the spelling of your entry and try again.

             CAUSE        The device specified is not configured.

             ACTION       Check the list of configured devices and try
                          again.

--------------------------------------------------------------------------

NMERR 172    MESSAGE      Specified pathname is not a datacom device.

             CAUSE        The specified pathname is not a valid datacom
                          device address.

             ACTION       Check the pathname in the configuration file and
                          re-enter.

--------------------------------------------------------------------------

NMERR 175    MESSAGE      Unexpected internal error accessing
                          configuration data.  (NMERR 175)

             CAUSE        An unexpected error has occurred.

             ACTION       See "Submitting an SR" at the beginning of this
                          appendix.

--------------------------------------------------------------------------



MPE/iX 5.0 Documentation