Powerfail Recovery [ Troubleshooting Terminal, Printer, and Serial Device Connections ] MPE/iX 5.0 Documentation
Troubleshooting Terminal, Printer, and Serial Device Connections
Powerfail Recovery
Powerfail recovery works for direct-connect sessions using character
mode. The system also attempts to recover direct-connect sessions using
block mode; however, this might not be successful if the powerfail has
affected terminal configuration. This is especially true for VPLUS
applications.
In the event of a DTC powerfail, some data loss might occur. Data
buffered in the DTC at the time of the powerfail is not recoverable.
Upon system powerfail, the DTC retains sessions for approximately 20
minutes. This exceeds the duration of battery back-up on the system (15
minutes). Upon DTC powerfail, the system also retains sessions for about
20 minutes. If power is not restored before this time, sessions are
aborted.
The terminal appears "hung" for approximately two minutes after power has
been restored to the DTC (the time it takes for the DTC selftest and
download to complete). After this time, device control is restored. No
"powerfail occurred" message is displayed. To confirm that device
control has been restored, press Enter until the colon prompt ( :) is
displayed.
In the event of a DTC powerfail, printer and modem connections are
aborted.