Ap B. Results of Multiple Access [ TurboIMAGE/XL Database Management System Reference Manual ] MPE/iX 5.0 Documentation
TurboIMAGE/XL Database Management System Reference Manual
Appendix B Results of Multiple Access
When opening a database with DBOPEN, TurboIMAGE/XL returns information in
the status array describing the results of the procedure call. Figure
B-1 can be used to interpret these results when multiple processes
are using the database.
Each box in Figure B-1 is associated with a requested mode or
TurboIMAGE/XL utility routine identified at the far left of the row in
which the box appears. It is also associated with a possible current
access mode or utility routine identified at the top of the column in
which the box appears. The contents of the boxes can be used to
determine the results of a DBOPEN call.
If access is granted, condition code CCE is returned and the first
element of the status array contains a zero. The boxes containing G
represent this situation.
If access is not granted, and the reason relates to current database
activity, the results are like those shown in the other boxes. Two types
of situations can occur:
* If the first two elements of the status array contain -1 and 0,
respectively, the third element of status will contain a single
number. This number is the MPE/iX failure code returned from the
FCHECK intrinsic. See the MPE/iX Intrinsic Reference Manual for
MPE/iX failure code meanings. If that number is 48, 90, or 91,
the failure occurred because current access to the database does
not permit it to be opened in the requested mode. Find the boxes
in the requested mode row which contain a number equal to the
third status element. The possible modes and utility routines
which other processes could be using are the ones which label the
columns containing these boxes. For example, if the third status
element contains 48 and the requested mode is 2, the possible
current modes are 1 and 5.
To find an alternate mode for accomplishing the task, look down
the columns containing these boxes for one containing a G. If the
requested mode labeling the row in which the G resides can be
used, try opening the database with that mode. In the example
above, alternate modes would be 1 or 5 because these rows contain
G in columns 1 and 5.
If the box with contents matching the third status element is in a
column associated with a utility, usually the only choice is to
wait until execution terminates. When DBSTORE is being run, it is
possible to open the database with mode 6 or 8.
* If the first element in the status array contains -32, the failure
occurred because the root file could be opened but not with the
necessary AOPTIONS. This value can also be returned in situations
not related to multiple access. See appendix A in this manual and
the description of the AOPTIONS parameter of the FOPEN intrinsic
in the MPE/iX Intrinsics Reference Manual. Use the same technique
described above to determine the possible current modes or other
activity and to select a course of action. For example, if the
requested mode is 2 and the first element of status equals -32,
possible current modes are 4 and 8, and the DBSTORE utility could
be executing.
The messages enclosed in quotes are printed when the situation
represented by the row and column headings occurs.
Figure B-1. Actions Resulting from Multiple Access of Databases
MPE/iX 5.0 Documentation