>STOP [ Silhouette Reference Manual ] MPE/iX 5.0 Documentation
Silhouette Reference Manual
>STOP
The >STOP command discontinues duplicating the current configuration
file.
SYNTAX
>STOP [configfile]
PARAMETERS
configfile The name of the configuration file for which duplication is to be
discontinued.
DISCUSSION
When a >STOP command is issued, Silhouette waits until a quiet period
occurs and then shuts down the system in an orderly fashion. Note the
word Pending in the example display. Once the >STOP has successfully
completed, you will be unable to get a STATUS display since the
configuration will no longer be active.
NOTE Issuing a >RESUME command while a >STOP command is waiting for a
quiet period cancels the >STOP command.
EXAMPLES
The following example shows the STATUS report that appears while the
>STOP command is pending.
>STOP
Terminate remote: Successful execution of function / request. (RQMSG 0)
>STATUS
================ S i l h o u e t t e S T A T U S ================
1:05:36
* PRIMARY SECONDARY
- - - - - - - - - - - - - - - - - - + - - - - - - - - - - - - - - - - - - -
LOGFILE record # = 4655 (001) | LOGFILE record # = 4655 (001)
time = 1:05:31 | time = 1:05:31
|
outstanding= 0 recs | FLAGS Stop: Pending
max ever = 2 recs |
|
SENT logical = 3 recs | DATABASE opens = 6 paths
physical = 2 blocks | transact. = 2 outst.
| Open mode = 4 UNLOCK
|
[ current status ] | [ current status ]
- - - - - - - - - - - - - - - - - - + - - - - - - - - - - - - - - - - - - -
LINES OPEN : MPEXL950
=========================================================================
>
If a >STATUS command is issued after the >STOP command has successfully
completed, the following message appears:
No configuration is currently active. (MPWARN 42)
ADDITIONAL DISCUSSION
See Chapter 3.
MPE/iX 5.0 Documentation