POWER.
BLOCKGP=n Theblock group size for data files. Specify
this parameter for FBA devices only.
Recommended value: 0
Default: 0
COPYSEP=YES/NO Specifieswhether separator pages/cards are
produced between each copy of the output.
Recommended value: YES
Default: YES
DBLK=n Theblock size of data file records and the size
of each data buffer. If this parameter is
omitted or set to zero, VSE/POWER chooses the
appropriate block size.
Range: 548-2008
Recommended value: 0
Default: 0
JLOG=YES/NO Specifieswhether job information messages will
be logged on the system console.
Recommended value: YES
Default: YES
JSEP=(n,m) Thenumber of separator pages (n) and separator
cards (m) to be included in the output to
separate jobs.
Range: 0-9
Recommended value: (1,1)
Default: (0,0)
NTFYMSG=nnn Thenumber of messages to be kept in the notify
queue.
Range: 1-999
Recommended value: 64
PAUSE=YES/NO Specifieswhether the punch writer task will
wait before a job entry is punched.
Recommended value: NO
Default: NO
PRI=n Ifa priority is not specified on the * $ $ JOB
statement, the priority will default to the
value specified here.
Range: 1-9
Default: 3
RBS=(n,m) Thenumber of pages and cards to be processed
before segmentation happens.
Range: 1-999999
Recommended value: (0,0)
Default: (0,0), which means no segmentation.
RJEBSC=YES/NO Specifieswhether RJEBSC code should be loaded.
If no BSC nodes exist, specify NO.
Recommended value: NO
Default: YES
SNA=(,,POWER) Thehost job entry subsystem VTAM expects.
STDCARD=(n,m) Thenumber of job entry cards that can be
punched before a warning message is issued. 0
means no warning messages will be sent.
Range: 1-999999
Recommended value: (0,0)
Default: (0,0)
STDLINE=(n,m) Thenumber of records that can be printed before
a warning message is issued. 0 means no
warning messages will be sent.
Range: 1-999999
Recommended value: (0,0)
Default: (0,0)
POWER Macro and Parameters
PRMT.
CMPACT=name Do not specify this parameter. Hewlett-Packard
does not support compaction.
CONSOLE=YES Specifieswhether outbound data will be
interrupted for messages to the remote
operator. This parameter can be specified only
if the workstation has a line printer in
addition to a terminal console.
LSTROUT Thedefault destination for output from jobs
submitted by this remote workstation. If this
parameter is omitted, the output will be sent
to the device specified by the value of the
REMOTE parameter (described below).
LU=name Do not specify this parameter.
PSWRD=password Thepassword for the remote station being
defined.
PUNROUT Thedefault destination for punch output from
jobs submitted by this remote workstation. If
this parameter is omitted, the output will be
sent to the device specified by the value of
the REMOTE parameter (described below).
REMOTE=nnn Theremote identifier. SNA remote identifiers
must be higher than BSC identifiers.
Range: 1-200
SESSLIM=6 Themaximum number of sessions that can be
logged on at this workstation.
Default: 1
TYPE=LUT1 Thetype of terminal to be supported.
XLATE=NO Specifieswhether host outbound SCS control
characters are replaced with blanks.
Default: NO