SHOWIN and SHOWOUT Changes [ COMMUNICATOR 3000 MPE/iX General Release 5.0 (Core Software Release C.50.00) ] MPE/iX Communicators
COMMUNICATOR 3000 MPE/iX General Release 5.0 (Core Software Release C.50.00)
SHOWIN and SHOWOUT Changes
by Rick Ehrhart
Commercial Systems Division
Due to the increased number of devices supported in this MPE/iX release,
some changes to the output of the SHOWIN and SHOWOUT commands were
required. Prior to MPE/iX Release 5.0, the Device File IDs (DFIDs) were
incremented for each open of a device. Now, the DFID for non-printer
devices are now equal to the LDEV number for that device. This means
that the #O number or #I number is equal to the LDEV number. There are
no column or formatting changes.
For example, prior to MPE/iX Release 5.0, the non-printer SHOWOUT output
format looked like this:
:showout dev=20;job=@
_______________________________________________________________________
| |
| DEV/CL DFID JOBNUM FNAME STATE FRM SPACE RANK PRI #C|
| 20 #O335 #S508 $STDLIST OPENED |
| |
| OUTFENCE = 6 |
_______________________________________________________________________
With this release of MPE/iX, the SHOWOUT output format looks like this:
:showout dev=20;job=@
_______________________________________________________________________
| |
| DEV/CL DFID JOBNUM FNAME STATE FRM SPACE RANK PRI #C|
| 20 #O20 #S508 $STDLIST OPENED |
| |
| OUTFENCE = 6 |
_______________________________________________________________________
Prior to MPE/iX Release 5.0, the non-printer SHOWIN output format looked
like this:
:showin dev=20;job=@
_______________________________________________________________________
| |
| DEV/CL DFID JOBNUM FNAME STATE FRM SPACE RANK PRI #C|
| 20 #I326 #S508 $STDIN OPENED |
_______________________________________________________________________
With this release of MPE/iX, the SHOWIN output format looks like this:
:showin dev=20;job=@
_______________________________________________________________________
| |
| DEV/CL DFID JOBNUM FNAME STATE FRM SPACE RANK PRI #C|
| 20 #I20 #S508 $STDIN OPENED |
_______________________________________________________________________
For hot (non-spooled) printer devices, DFIDs starts at DFID #O6552 and
increases to DFID #O32767. Multiple hot devices could have the same
DFID.
DFIDs for spooled devices have not changed and start at DFID #O1 and
increase to as high as #O9999999. These limits can be changed with the
SETCOUNTER command (see the article, "Introducing the SETCOUNTER
Command", in this chapter for more details).
MPE/iX Communicators