This section describes error messages that might occur when you are shutting
down a LAP-B link. These messages appear when a NETCONTROL STOP command
calls the WAN_Kill_Module and encounters an error. They are displayed
on the HPe 3000 operator's console inq the following format:
WAN KILL MODULE (linkname) Message textWAN KILL MODULE (linkname) Error ErrorNum, Status = Status, Path:
PhysPath
MESSAGE: Could not stop trace.
Level: 51
CAUSE: Trace may have been turned off via the LINKCONTROL
command, but the link software status indicates that it was on.
ACTION: Ignore this problem unless you are experiencing other
problems. Otherwise record the error information printed on the console and
contact your Hewlett-Packard representative.
MESSAGE: The link is not in the link table.
Level: 52
CAUSE: The link specified is not active.
ACTION: If the link name is incorrect, issue the command again
with the correct linkname. If the link name is correct, the link has
already been shutdown and no action is necessary.
MESSAGE: The link type is not SDLC, LAP-B, or RJE.
Level: 53
CAUSE: The caller of this module did not set the link
type to one of SDLC, LAP-B, or RJE.
ACTION: Please record the error information printed on the console
and contact your Hewlett-Packard representative.
MESSAGE: Could not delete the link from the link table.
Level: 54
CAUSE: The link name specified is not in the link table.
ACTION: Check that the link name is correct and try again.
The link may have already been shutdown.
MESSAGE: Could not unconfigure the link from the system.
Level: 55
CAUSE: The I/O subsystem does not have any record of
this link being active.
ACTION: Check that the link name is correct and try again.
The link may have already been shutdown.
MESSAGE: Could not delete the auxiliary buffer pool.
Level: 56
CAUSE: There are many reasons why this could happen.
The status indicator provides more detailed information as to the
specific cause of the problem.
ACTION: Please record the error information printed on the console
and contact your Hewlett-Packard representative.
MESSAGE: Could not determine the PSI path number IO Serv.
Level: 57
CAUSE: The I/O subsystem does not have a physical path
for the link that was specified and therefore cannot deconfigure
it from the system.
ACTION: Check that the link name is correct and try
again.