Class error 1 is composed of three types of processor failures: register file,
execution unit, and instruction unit.
Register File Failure
Register file messages take the form:
11xx
where:
xx = detailed error number.
Register File Messages 00 - 51
00
MESSAGE
No message. System halts. (E)
CAUSE
Undefined error occurs at the start of the test.
ACTION
Contact your Hewlett-Packard Support Representative.
01
MESSAGE
No message. System halts. (E)
CAUSE
Test of the general registers 1, 2, and 31 fails. Second possible
cause of the error may be the execution unit. Third possible cause of
the error also may be the instruction unit.
ACTION
Contact your Hewlett-Packard Support Representative.
02
MESSAGE
No message. System halts. (E)
CAUSE
Test of the general registers fails. Second possible cause of the
error may be the execution unit. Third possible cause of the error also
may be the instruction unit.
ACTION
Contact your Hewlett-Packard Support Representative.
03
MESSAGE
No message. System halts. (E)
CAUSE
Test of the recovery counter or external interrupt enable mask
fails. Second possible cause of the error may be the execution unit.
Third possible cause of the error also may be the instruction
unit.
ACTION
Contact your Hewlett-Packard Support Representative.
04
MESSAGE
No message. System halts. (E)
CAUSE
Test of the temporary control registers fails. Second possible
cause of the error may be the execution unit. Third possible cause
of the error also may be the instruction unit.
ACTION
Contact your Hewlett-Packard Support Representative.
07
MESSAGE
No message. System halts. (E)
CAUSE
Cross-talk occurs between general registers.
ACTION
Contact your Hewlett-Packard Support Representative.
08
MESSAGE
No message. System halts. (E)
CAUSE
Crosstalk occurs among general registers and temporary
registers.
ACTION
Contact your Hewlett-Packard Support Representative.
0A
MESSAGE
No message. System halts. (E)
CAUSE
X and B bus bypass testing.
ACTION
Contact your Hewlett-Packard Support Representative.
0B
MESSAGE
No message. System halts. (E)
CAUSE
General register 0 bypassed.
ACTION
Contact your Hewlett-Packard Support Representative.
0C
MESSAGE
No message. System halts. (E)
CAUSE
General register 0 bypassed on a nullify.
ACTION
Contact your Hewlett-Packard Support Representative.
0D
MESSAGE
No message. System halts. (E)
CAUSE
Verification of the trap with interval timer fails.
ACTION
Contact your Hewlett-Packard Support Representative.
10
MESSAGE
No message. System halts. (E)
CAUSE
Interval timer is not incrementing. Second possible
cause of the error may be the execution unit. Third possible cause
of the error also may be the instruction unit.
ACTION
Contact your Hewlett-Packard Support Representative.
11
MESSAGE
No message. System halts. (E)
CAUSE
Interval timer is not causing a trap. Second possible
cause of the error may be the instruction unit. Third possible cause
of the error also may be the translation look-aside buffer.
ACTION
Contact your Hewlett-Packard Support Representative.
12
MESSAGE
No message. System halts. (E)
CAUSE
Recovery counter is not causing a trap. Second possible cause
of the error may be the instruction unit. Third possible cause of
the error also may be the translation look-aside buffer.
ACTION
Contact your Hewlett-Packard Support Representative.
15
MESSAGE
No message. System halts. (E)
CAUSE
Load to general register 0 modifies that register.
ACTION
Contact your Hewlett-Packard Support Representative.
16
MESSAGE
No message. System halts. (E)
CAUSE
Nullified instruction stored to register file
ACTION
Contact your Hewlett-Packard Support Representative.
17
MESSAGE
No message. System halts. (E)
CAUSE
Verification of the address calculation for load word and
modification (LDWM) fails.
ACTION
Contact your Hewlett-Packard Support Representative.
18
MESSAGE
No message. System halts. (E)
CAUSE
Verification of the address calculation for load word indexed and
modification (LDWX,M) fails.
ACTION
Contact your Hewlett-Packard Support Representative.
19
MESSAGE
No message. System halts. (E)
CAUSE
Verification of the address calculation for load byte indexed and
modification (LDBX,U,M) fails.
ACTION
Contact your Hewlett-Packard Support Representative.
1A
MESSAGE
No message. System halts. (E)
CAUSE
Verification of the address calculation for load
half word indexed and modification (LDHX,U,M) fails.
ACTION
Contact your Hewlett-Packard Support Representative.
1B
MESSAGE
No message. System halts. (E)
CAUSE
Verification of the address calculation for load
halfword indexed and modification (LDWX,U,M) fails.
ACTION
Contact your Hewlett-Packard Support Representative.
20
MESSAGE
No message. System halts. (E)
CAUSE
Verification of the operation of the register file
interlock fails.
ACTION
Contact your Hewlett-Packard Support Representative.
21
MESSAGE
No message. System halts. (E)
CAUSE
Verification of the address calculation for load
word and modification after (LDW,MA) fails.
ACTION
Contact your Hewlett-Packard Support Representative.
22
MESSAGE
No message. System halts. (E)
CAUSE
Verification of the address calculation for load
word and modification before (LDW,MB) fails.
ACTION
Contact your Hewlett-Packard Support Representative.
23
MESSAGE
No message. System halts. (E)
CAUSE
Verification of the move to control register (MTCTL)
after load word (LDW) operation fails.
ACTION
Contact your Hewlett-Packard Support Representative.
2A
MESSAGE
No message. System halts. (E)
CAUSE
Nullified instruction after data trap stored to
register file.
ACTION
Contact your Hewlett-Packard Support Representative.
2B
MESSAGE
No message. System halts. (E)
CAUSE
Verification of the address calculation of the load
and modification that caused the data trap fails.
ACTION
Contact your Hewlett-Packard Support Representative.
2C
MESSAGE
No message. System halts. (E)
CAUSE
Verification of the ripple through recovery counter fails.
ACTION
Contact your Hewlett-Packard Support Representative.
2D
MESSAGE
No message. System halts. (E)
CAUSE
Cannot force overflow trap.
ACTION
Contact your Hewlett-Packard Support Representative.
2E
MESSAGE
No message. System halts. (E)
CAUSE
Verification of the backup on recovery counter fails.
ACTION
Contact your Hewlett-Packard Support Representative.
2F
MESSAGE
No message. System halts. (E)
CAUSE
Verification of the late nullify on recovery counter fails.
ACTION
Contact your Hewlett-Packard Support Representative.
31
MESSAGE
No message. System halts. (E)
CAUSE
Unexpected recovery counter trap occurs. Second possible cause of
the error may be the instruction unit. Third possible cause of the
error also may be the translation look-aside buffer.
ACTION
Contact your Hewlett-Packard Support Representative.
32
MESSAGE
No message. System halts. (E)
CAUSE
Unexpected external interrupt trap occurs. Second possible
cause of the error may be the instruction unit. Third possible cause
of the error also may be the translation look-aside buffer.
ACTION
Contact your Hewlett-Packard Support Representative.
40
MESSAGE
No message. System halts. (E)
CAUSE
Test of the external interrupt request register
with zero fails.
ACTION
Contact your Hewlett-Packard Support Representative.
41
MESSAGE
No message. System halts. (E)
CAUSE
Verification of the value of general register 1
after ADDIL instruction fails.
ACTION
Contact your Hewlett-Packard Support Representative.
42
MESSAGE
No message. System halts. (E)
CAUSE
Verification of the calculation of the return address
with branch and link instruction fails.
ACTION
Contact your Hewlett-Packard Support Representative.
43
MESSAGE
No message. System halts. (E)
CAUSE
Register file does not zero unused portion of the
target register for LDH instruction.
ACTION
Contact your Hewlett-Packard Support Representative.
44
MESSAGE
No message. System halts. (E)
CAUSE
Register file does not zero unused portion of the
target register for LDB instruction.
ACTION
Contact your Hewlett-Packard Support Representative.
45
MESSAGE
No message. System halts. (E)
CAUSE
Cannot distinguish between banks of the general registers.
ACTION
Contact your Hewlett-Packard Support Representative.
46
MESSAGE
No message. System halts. (E)
CAUSE
Verification of the recovery counter operation fails. Counter
cannot count up.
ACTION
Contact your Hewlett-Packard Support Representative.
47
MESSAGE
No message. System halts. (E)
CAUSE
Verification of the recovery counter operation with
nullify instruction fails.
ACTION
Contact your Hewlett-Packard Support Representative.
48
MESSAGE
No message. System halts. (E)
CAUSE
Verification of the recovery counter operation with
late nullify instruction fails.
ACTION
Contact your Hewlett-Packard Support Representative.
49
MESSAGE
No message. System halts. (E)
CAUSE
Verification of the recovery counter operation with
late nullify instruction caused by data trap fails.
ACTION
Contact your Hewlett-Packard Support Representative.
4A
MESSAGE
No message. System halts. (E)
CAUSE
Verification of the recovery counter trap fails.
ACTION
Contact your Hewlett-Packard Support Representative.
4B
MESSAGE
No message. System halts. (E)
CAUSE
Verification of the recovery counter trap operation immediately
after data trap fails.
ACTION
Contact your Hewlett-Packard Support Representative.
4C
MESSAGE
No message. System halts. (E)
CAUSE
Cannot verify external interrupt enable mask.
ACTION
Contact your Hewlett-Packard Support Representative.
Contact your Hewlett-Packard Support Representative.
4E
MESSAGE
No message. System halts. (E)
CAUSE
Verification of the external interrupt operation fails.
ACTION
Contact your Hewlett-Packard Support Representative.
4F
MESSAGE
No message. System halts. (E)
CAUSE
Cannot verify current privilege level after execution
of the gateway instruction.
ACTION
Contact your Hewlett-Packard Support Representative.
50
MESSAGE
No message. System halts. (E)
CAUSE
Verification of the timing on board fails.
ACTION
Contact your Hewlett-Packard Support Representative.
51
MESSAGE
No message. System halts. (E)
CAUSE
Verification of the external interrupt request register with
high-priority machine check fails. (EIRR bit gets set with
HPMC.)
ACTION
Contact your Hewlett-Packard Support Representative.
Execution Unit Failure
Execution unit messages take the form:
14xx
where:
xx = detailed error number.
Execution Unit Messages 00 - 22
00
MESSAGE
No message. System halts. (E)
CAUSE
Undefined error occurs at the start of the test on this board.
ACTION
Contact your Hewlett-Packard Support Representative.
01
MESSAGE
No message. System halts. (E)
CAUSE
Test of the data path through the barrel shifter fails.
ACTION
Contact your Hewlett-Packard Support Representative.
02
MESSAGE
No message. System halts. (E)
CAUSE
Shift by bit 0, 1, 2, 4, 6, 8, 16, or 31 fails.
ACTION
Contact your Hewlett-Packard Support Representative.
03
MESSAGE
No message. System halts. (E)
CAUSE
Pattern test of the 3/4-bit hardware boundaries fails.
ACTION
Contact your Hewlett-Packard Support Representative.
04
MESSAGE
No message. System halts. (E)
CAUSE
Preshift by 0 bit for MOVE fails.
ACTION
Contact your Hewlett-Packard Support Representative.
05
MESSAGE
No message. System halts. (E)
CAUSE
Extract sign/unsigned for a bit field fails.
ACTION
Contact your Hewlett-Packard Support Representative.
06
MESSAGE
No message. System halts. (E)
CAUSE
Timing critical path of instruction mix MTCTL and VEXTRS fails.
ACTION
Contact your Hewlett-Packard Support Representative.
07
MESSAGE
No message. System halts. (E)
CAUSE
Verification of the shift amount register fails.
ACTION
Contact your Hewlett-Packard Support Representative.
0A
MESSAGE
No message. System halts. (E)
CAUSE
Arithmetic/logical conditions fail.
ACTION
Contact your Hewlett-Packard Support Representative.
0B
MESSAGE
No message. System halts. (E)
CAUSE
Test of the unit conditions fails.
ACTION
Contact your Hewlett-Packard Support Representative.
0C
MESSAGE
No message. System halts. (E)
CAUSE
Test of the extract/logical conditions fails.
ACTION
Contact your Hewlett-Packard Support Representative.
0D
MESSAGE
No message. System halts. (E)
CAUSE
Test of the PSW C/B bit fails. Second cause of the error may be the
register file.
ACTION
Contact your Hewlett-Packard Support Representative.
10
MESSAGE
No message. System halts. (E)
CAUSE
Verification of the shift and add conditions fails.
ACTION
Contact your Hewlett-Packard Support Representative.
11
MESSAGE
No message. System halts. (E)
CAUSE
Cannot verify shift one and add.
ACTION
Contact your Hewlett-Packard Support Representative.
12
MESSAGE
No message. System halts. (E)
CAUSE
Cannot verify shift two and add.
ACTION
Contact your Hewlett-Packard Support Representative.
13
MESSAGE
No message. System halts. (E)
CAUSE
Cannot verify shift three and add.
ACTION
Contact your Hewlett-Packard Support Representative.
14
MESSAGE
No message. System halts. (E)
CAUSE
Verification of the load byte short with odd index fails.
ACTION
Contact your Hewlett-Packard Support Representative.
15
MESSAGE
No message. System halts. (E)
CAUSE
Verification of the operation of the PSW's C/B bits with decimal
correct (DCOR) instruction fails.
ACTION
Contact your Hewlett-Packard Support Representative.
16
MESSAGE
No message. System halts. (E)
CAUSE
Verification of the PSW's C/B bits with logical shift operation
fails. (C/B gets updated.)
ACTION
Contact your Hewlett-Packard Support Representative.
17
MESSAGE
No message. System halts. (E)
CAUSE
Cannot verify operation of the logical add.
ACTION
Contact your Hewlett-Packard Support Representative.
18
MESSAGE
No message. System halts. (E)
CAUSE
Verification of the PSW's C/B bits with logical add operation fails.
(C/B gets updated.)
ACTION
Contact your Hewlett-Packard Support Representative.
19
MESSAGE
No message. System halts. (E)
CAUSE
Addition of two negative numbers cause overflow trap.
ACTION
Contact your Hewlett-Packard Support Representative.
1A
MESSAGE
No message. System halts. (E)
CAUSE
Cannot verify addition of two negative numbers.
ACTION
Contact your Hewlett-Packard Support Representative.
20
MESSAGE
No message. System halts. (E)
CAUSE
Verification of the overflow conditions with logical ADD instruction
fails.
ACTION
Contact your Hewlett-Packard Support Representative.
21
MESSAGE
No message. System halts. (E)
CAUSE
Verification of the overflow conditions with EXTRU logical
instruction fails.
ACTION
Contact your Hewlett-Packard Support Representative.
22
MESSAGE
No message. System halts. (E)
CAUSE
Verification of the extract signed instruction operation fails.
ACTION
Contact your Hewlett-Packard Support Representative.
Instruction Unit Failure
Instruction unit messages take the form:
15xx
where:
xx = detailed error number.
Instruction Unit Messages 00 - 59
00
MESSAGE
No message. System halts. (E)
CAUSE
Undefined error occurs at the start of the test of this
board.
ACTION
Contact your Hewlett-Packard Support Representative.
01
MESSAGE
No message. System halts. (E)
CAUSE
Condition branch test fails. Second possible cause
of the error is the execution unit. Third possible cause also may be
the register file unit.
ACTION
Contact your Hewlett-Packard Support Representative.
02
MESSAGE
No message. System halts. (E)
CAUSE
Condition add with no overflow fails. Second possible cause
of the error is the execution unit Third possible cause also may
be the register file unit.
ACTION
Contact your Hewlett-Packard Support Representative.
03
MESSAGE
No message. System halts. (E)
CAUSE
Odd condition fails. Second possible cause of the error is the
execution unit. Third possible cause also may be the register
file unit.
ACTION
Contact your Hewlett-Packard Support Representative.
04
MESSAGE
No message. System halts. (E)
CAUSE
Test of the unit true condition fails. Second possible cause of the
error is the execution unit. Third possible cause also may
be the register file unit.
ACTION
Contact your Hewlett-Packard Support Representative.
05
MESSAGE
No message. System halts. (E)
CAUSE
Test of the ext/dep true condition fails. Second
possible cause of the error is the execution unit. Third possible cause
also may be the register file unit.
ACTION
Contact your Hewlett-Packard Support Representative.
08
MESSAGE
No message. System halts. (E)
CAUSE
Branch and link instruction cannot calculate the return address.
Second possible cause of the error is the execution unit.
Third possible cause also may be the register file unit.
ACTION
Contact your Hewlett-Packard Support Representative.
09
MESSAGE
No message. System halts. (E)
CAUSE
Branch and vector instruction cannot return to the given address.
Second possible cause of the error is the execution unit.
Third possible cause also may be the register file unit.
ACTION
Contact your Hewlett-Packard Support Representative.
0A
MESSAGE
No message. System halts. (E)
CAUSE
Verification of the system mask portion of the PSW
fails. Second possible cause of the error is the execution unit Third
possible cause also may be the register file unit.
ACTION
Contact your Hewlett-Packard Support Representative.
0B
MESSAGE
No message. System halts. (E)
CAUSE
Verification of the coprocessor fails. Second possible
cause of the error is the execution unit.
ACTION
Contact your Hewlett-Packard Support Representative.
0C
MESSAGE
No message. System halts. (E)
CAUSE
Verification of the interrupt vector address or PC offset queue
fails. Second possible cause of the error is the execution
unit.
ACTION
Contact your Hewlett-Packard Support Representative.
0D
MESSAGE
No message. System halts. (E)
CAUSE
Verification of the interrupt processor status word fails. Second
possible cause of the error is the execution unit.
ACTION
Contact your Hewlett-Packard Support Representative.
0E
MESSAGE
No message. System halts. (E)
CAUSE
Verification of the PC offset queue operation fails. (Cannot verify
the functionality of the PSW Q bit.) Second possible cause
of the error is the translation look-aside buffer.
ACTION
Contact your Hewlett-Packard Support Representative.
0F
MESSAGE
No message. System halts. (E)
CAUSE
Instruction unit cannot force trap. Second possible
cause of the error is the register file unit.
ACTION
Contact your Hewlett-Packard Support Representative.
16
MESSAGE
No message. System halts. (E)
CAUSE
PC offset queue does not hold the correct address
after trap.
ACTION
Contact your Hewlett-Packard Support Representative.
17
MESSAGE
No message. System halts. (E)
CAUSE
IPSW does not receive the value of the PSW after trap.
ACTION
Contact your Hewlett-Packard Support Representative.
18
MESSAGE
No message. System halts. (E)
CAUSE
Interrupt instruction register does not receive
the value of the instruction that causes a trap.
ACTION
Contact your Hewlett-Packard Support Representative.
19
MESSAGE
No message. System halts. (E)
CAUSE
Verification of the forced break instruction trap fails.
ACTION
Contact your Hewlett-Packard Support Representative.
20
MESSAGE
No message. System halts. (E)
CAUSE
Verification of the forced illegal instruction trap fails.
ACTION
Contact your Hewlett-Packard Support Representative.
21
MESSAGE
No message. System halts. (E)
CAUSE
Verification of the forced overflow trap fails.
ACTION
Contact your Hewlett-Packard Support Representative.
22
MESSAGE
No message. System halts. (E)
CAUSE
Verification of the forced conditional trap fails.
ACTION
Contact your Hewlett-Packard Support Representative.
23
MESSAGE
No message. System halts. (E)
CAUSE
Cannot verify the functionality of the PSW's T bit
during a verification of the forced branch taken trap.
ACTION
Contact your Hewlett-Packard Support Representative.
24
MESSAGE
No message. System halts. (E)
CAUSE
Cannot verify the functionality of the PSW's B bit.
ACTION
Contact your Hewlett-Packard Support Representative.
25
MESSAGE
No message. System halts. (E)
CAUSE
Cannot enable a high-priority machine check with PSW's M
bit.
ACTION
Contact your Hewlett-Packard Support Representative.
26
MESSAGE
No message. System halts. (E)
CAUSE
Cannot disable the high-priority machine check with PSW's M
bit.
ACTION
Contact your Hewlett-Packard Support Representative.
27
MESSAGE
No message. System halts. (E)
CAUSE
Cannot verify the change of privilege with branch external (BE)
instruction.
ACTION
Contact your Hewlett-Packard Support Representative.
28
MESSAGE
No message. System halts. (E)
CAUSE
Cannot verify the change of privilege with branch and link external
(BLE) instruction.
ACTION
Contact your Hewlett-Packard Support Representative.
29
MESSAGE
No message. System halts. (E)
CAUSE
Cannot verify the change of privilege with branch
vector (BV) instruction.
ACTION
Contact your Hewlett-Packard Support Representative.
2A
MESSAGE
No message. System halts. (E)
CAUSE
Cannot verify the functionality of the privilege
register trap.
ACTION
Contact your Hewlett-Packard Support Representative.
2B
MESSAGE
No message. System halts. (E)
CAUSE
Cannot verify the functionality of the privilege
operation trap.
ACTION
Contact your Hewlett-Packard Support Representative.
2C
MESSAGE
No message. System halts. (E)
CAUSE
Cannot verify the functionality of the lower privilege transfer
trap.
ACTION
Contact your Hewlett-Packard Support Representative.
2D
MESSAGE
No message. System halts. (E)
CAUSE
Cannot verify the functionality of the higher privilege transfer
trap.
ACTION
Contact your Hewlett-Packard Support Representative.
31
MESSAGE
No message. System halts. (E)
CAUSE
Unexpected high-priority machine check trap occurs. Second
possible cause of the error is the register file. Third possible
cause of the error is the translation look-aside buffer (TLB).
ACTION
Contact your Hewlett-Packard Support Representative.
32
MESSAGE
No message. System halts. (E)
CAUSE
Unexpected low parity machine check trap occurs. Second possible
cause of the error is the register file. Third possible
cause of the error is the TLB.
ACTION
Contact your Hewlett-Packard Support Representative.
33
MESSAGE
No message. System halts. (E)
CAUSE
Unexpected illegal instruction trap occurs. Second
possible cause of the error is the register file. Third possible
cause of the error is the TLB.
ACTION
Contact your Hewlett-Packard Support Representative.
34
MESSAGE
No message. System halts. (E)
CAUSE
Unexpected break instruction trap occurs. Second
possible cause of the error is the register file. Third possible
cause of the error is the TLB.
ACTION
Contact your Hewlett-Packard Support Representative.
35
MESSAGE
No message. System halts. (E)
CAUSE
Unexpected privileged operation trap occurs. Second possible
cause of the error is the register file. Third possible cause of
the error is the TLB.
ACTION
Contact your Hewlett-Packard Support Representative.
36
MESSAGE
No message. System halts. (E)
CAUSE
Unexpected privileged register trap occurs. Second possible
cause of the error is the register file. Third possible cause of
the error is the TLB.
ACTION
Contact your Hewlett-Packard Support Representative.
37
MESSAGE
No message. System halts. (E)
CAUSE
Unexpected overflow trap occurs. Second possible
cause of the error is the register file. Third possible cause of
the error is the TLB.
ACTION
Contact your Hewlett-Packard Support Representative.
38
MESSAGE
No message. System halts. (E)
CAUSE
Unexpected condition trap occurs. Second possible
cause of the error is the register file. Third possible cause of
the error is the TLB.
ACTION
Contact your Hewlett-Packard Support Representative.
39
MESSAGE
No message. System halts. (E)
CAUSE
Unexpected assist emulation trap occurs. Second
possible cause of the error is the register file. Third possible
cause of the error is the TLB.
ACTION
Contact your Hewlett-Packard Support Representative.
3A
MESSAGE
No message. System halts. (E)
CAUSE
Unexpected privilege transfer trap occurs. Second
possible cause of the error is the register file. Third possible
cause of the error is the TLB.
ACTION
Contact your Hewlett-Packard Support Representative.
3B
MESSAGE
No message. System halts. (E)
CAUSE
Unexpected low-privilege transfer trap occurs. Second possible
cause of the error is the register file. Third possible cause of
the error is the TLB.
ACTION
Contact your Hewlett-Packard Support Representative.
3C
MESSAGE
No message. System halts. (E)
CAUSE
Unexpected taken branch trap occurs. Second possible cause
of the error is the register file. Third possible cause of the error
is the TLB.
ACTION
Contact your Hewlett-Packard Support Representative.
3D
MESSAGE
No message. System halts. (E)
CAUSE
Unimplemented trap occurs. Second possible cause
of the error is the register file. Third possible cause of the error
is the TLB.
ACTION
Contact your Hewlett-Packard Support Representative.
40
MESSAGE
No message. System halts. (E)
CAUSE
Verification of the transfer of control/soft reset fails.
ACTION
Contact your Hewlett-Packard Support Representative.
41
MESSAGE
No message. System halts. (E)
CAUSE
Unexpected high-priority machine check is found
during forced TOC/soft reset.
ACTION
Contact your Hewlett-Packard Support Representative.
42
MESSAGE
No message. System halts. (E)
CAUSE
Cannot verify PCQ front after RFI with Q bit off.
ACTION
Contact your Hewlett-Packard Support Representative.
43
MESSAGE
No message. System halts. (E)
CAUSE
Cannot verify Assist Emulation trap, or cannot verify
bit zero of CCR.
ACTION
Contact your Hewlett-Packard Support Representative.
44
MESSAGE
No message. System halts. (E)
CAUSE
Cannot verify coprocessor configuration register
by forcing assist emulation trap.
ACTION
Contact your Hewlett-Packard Support Representative.
45
MESSAGE
No message. System halts. (E)
CAUSE
Cannot verify overflow trap with ADDIO instruction.
ACTION
Contact your Hewlett-Packard Support Representative.
46
MESSAGE
No message. System halts. (E)
CAUSE
Unexpected overflow trap occurs.
ACTION
Contact your Hewlett-Packard Support Representative.
47
MESSAGE
No message. System halts. (E)
CAUSE
Cannot verify index other than zero with BLR instruction.
ACTION
Contact your Hewlett-Packard Support Representative.
48
MESSAGE
No message. System halts. (E)
CAUSE
Cannot verify index other than zero with BV instruction.
ACTION
Contact your Hewlett-Packard Support Representative.
49
MESSAGE
No message. System halts. (E)
CAUSE
Cannot verify system mask (of PSW) with MTSM instruction.
ACTION
Contact your Hewlett-Packard Support Representative.
4E
MESSAGE
No message. System halts. (E)
CAUSE
Cannot verify functionality of PSW's N bit. N bit is not set for
nullified instruction when taken branch trap is taken.
ACTION
Contact your Hewlett-Packard Support Representative.
4F
MESSAGE
No message. System halts. (E)
CAUSE
Cannot verify functionality of PSW's N bit. When
N bit is set RFI target is not nullified.
ACTION
Contact your Hewlett-Packard Support Representative.
51
MESSAGE
No message. System halts. (E)
CAUSE
Cannot verify functionality of PSW's X bit. (Cannot prevent
data memory break trap by setting X bit.)
ACTION
Contact your Hewlett-Packard Support Representative.
52
MESSAGE
No message. System halts. (E)
CAUSE
Verification of PSW's V bit fails. (Cannot verify
the remainder of the divide step.)
ACTION
Contact your Hewlett-Packard Support Representative.
53
MESSAGE
No message. System halts. (E)
CAUSE
Verification of PSW's C bit fails.
ACTION
Contact your Hewlett-Packard Support Representative.
54
MESSAGE
No message. System halts. (E)
CAUSE
Verification of IPSW in virtual mode fails.
ACTION
Contact your Hewlett-Packard Support Representative.
55
MESSAGE
No message. System halts. (E)
CAUSE
Verification of PCQ in high virtual address fails.
ACTION
Contact your Hewlett-Packard Support Representative.
56
MESSAGE
No message. System halts. (E)
CAUSE
Verification of small displacement in high virtual
address fails.
ACTION
Contact your Hewlett-Packard Support Representative.
57
MESSAGE
No message. System halts. (E)
CAUSE
Verification of PSW when HPMC is forced by TLB parity error
fails.
ACTION
Contact your Hewlett-Packard Support Representative.
58
MESSAGE
No message. System halts. (E)
CAUSE
Cannot force HPMC in virtual mode.
ACTION
Contact your Hewlett-Packard Support Representative.
59
MESSAGE
No message. System halts. (E)
CAUSE
Verification of IPSW in virtual mode fails.
ACTION
Contact your Hewlett-Packard Support Representative.
Class Error 2
Class error 2 is composed of translation look-aside buffer (TLB) and cache
failures. These two types of errors are coded 23xx and 27xx.
Translation Look-Aside Buffer (TLB) Failure
translation look-aside buffer messages take the form:
26xx
where:
xx = detailed error number.
TLB Messages 00 - 40
00
MESSAGE
No message. System halts. (E)
CAUSE
Undefined error occurred at the start of the test of this
board.
ACTION
Contact your Hewlett-Packard Support Representative.
01
MESSAGE
No message. System halts. (E)
CAUSE
Verification of the read and write operation on the space registers
through space ID fails.
ACTION
Contact your Hewlett-Packard Support Representative.
02
MESSAGE
No message. System halts. (E)
CAUSE
Verification of the read and write operation on the space registers
through MTSP fails.
ACTION
Contact your Hewlett-Packard Support Representative.
04
MESSAGE
No message. System halts. (E)
CAUSE
Verification of the read or write access to a page
with proper protection and access right fails. Second possible cause
of the error is the cache unit.
ACTION
Contact your Hewlett-Packard Support Representative.
05
MESSAGE
No message. System halts. (E)
CAUSE
Verification of the write disable bit operation
fails. Second possible cause of the error is the cache unit.
ACTION
Contact your Hewlett-Packard Support Representative.
06
MESSAGE
No message. System halts. (E)
CAUSE
Verification of the public access operation fails.
Second possible cause of the error is the cache unit.
ACTION
Contact your Hewlett-Packard Support Representative.
07
MESSAGE
No message. System halts. (E)
CAUSE
Verification of the PSW P Bit operation fails. Second possible
cause of the error is the cache unit. Third possible cause of the
error is the instruction unit.
ACTION
Contact your Hewlett-Packard Support Representative.
08
MESSAGE
No message. System halts. (E)
CAUSE
Verification of the data TLB MISS trap operation fails. Second
possible cause of the error is the instruction unit.
ACTION
Contact your Hewlett-Packard Support Representative.
09
MESSAGE
No message. System halts. (E)
CAUSE
Verification of the non-access data TLB MISS trap operation fails.
Second possible cause of the error is the instruction unit.
ACTION
Contact your Hewlett-Packard Support Representative.
0A
MESSAGE
No message. System halts. (E)
CAUSE
Verification of the debug trap operation fails.
Second possible cause of the error is the instruction unit.
ACTION
Contact your Hewlett-Packard Support Representative.
0B
MESSAGE
No message. System halts. (E)
CAUSE
Verification of the dirty bit trap operation fails.
Second possible cause of the error is the instruction unit.
ACTION
Contact your Hewlett-Packard Support Representative.
0C
MESSAGE
No message. System halts. (E)
CAUSE
Verification of the virtual I/O trap operation fails.
Second possible cause of the error is the instruction unit.
ACTION
Contact your Hewlett-Packard Support Representative.
0D
MESSAGE
No message. System halts. (E)
CAUSE
Verification of the physical page number RAMs fails.
ACTION
Contact your Hewlett-Packard Support Representative.
10
MESSAGE
No message. System halts. (E)
CAUSE
Lower privilege trap does not occur. Second possible
cause of the error is the instruction unit.
ACTION
Contact your Hewlett-Packard Support Representative.
11
MESSAGE
No message. System halts. (E)
CAUSE
Verification of the data path through PIDs fails.
ACTION
Contact your Hewlett-Packard Support Representative.
12
MESSAGE
No message. System halts. (E)
CAUSE
Verification of the data path through PCSQ fails.
ACTION
Contact your Hewlett-Packard Support Representative.
13
MESSAGE
No message. System halts. (E)
CAUSE
Verification of the I bit functionality fails. Second
possible cause of the error is the cache unit.
ACTION
Contact your Hewlett-Packard Support Representative.
14
MESSAGE
No message. System halts. (E)
CAUSE
Verification of the physical address generation
or the physical page number RAM fails. Second possible cause of the
error is the cache unit.
ACTION
Contact your Hewlett-Packard Support Representative.
15
MESSAGE
No message. System halts. (E)
CAUSE
Verification of the read and write with virtual address operation
fails. Second possible cause of the error is the cache unit.
ACTION
Contact your Hewlett-Packard Support Representative.
16
MESSAGE
No message. System halts. (E)
CAUSE
Gateway instruction does not promote privilege to zero in a real
mode. Second possible cause is the instruction unit. Third
possible cause is the register file.
ACTION
Contact your Hewlett-Packard Support Representative.
18
MESSAGE
No message. System halts. (E)
CAUSE
Verification of the privilege level generation with gateway
instruction for page types 2 or 3 fails. Second possible cause is the
instruction unit. Third possible cause is the register file.
ACTION
Contact your Hewlett-Packard Support Representative.
19
MESSAGE
No message. System halts. (E)
CAUSE
Verification of the privilege level generation with gateway
instruction for page types 4, 5, 6, or 7 fails. Second possible cause
is the instruction unit. Third possible cause is the register
file.
ACTION
Contact your Hewlett-Packard Support Representative.
1A
MESSAGE
No message. System halts. (E)
CAUSE
Gateway instruction does not promote privilege to zero in a virtual
mode. Second possible cause is the instruction unit.
Third possible cause is the register file.
ACTION
Contact your Hewlett-Packard Support Representative.
1B
MESSAGE
No message. System halts. (E)
CAUSE
Verification of the execution of the gateway instruction
in delay slot of the branch fails. (No trap is generated.) Second
possible cause is the instruction unit.
ACTION
Contact your Hewlett-Packard Support Representative.
1C
MESSAGE
No message. System halts. (E)
CAUSE
Verification of the generation of a data memory protection trap
fails. Second possible cause is the instruction unit.
ACTION
Contact your Hewlett-Packard Support Representative.
1D
MESSAGE
No message. System halts. (E)
CAUSE
Verification of the generation of an instruction memory protection
trap fails. Second possible cause is the instruction unit.
ACTION
Contact your Hewlett-Packard Support Representative.
20
MESSAGE
No message. System halts. (E)
CAUSE
Verification of the ISR operation fails.
ACTION
Contact your Hewlett-Packard Support Representative.
21
MESSAGE
No message. System halts. (E)
CAUSE
Verification of the IOR operation fails.
ACTION
Contact your Hewlett-Packard Support Representative.
22
MESSAGE
No message. System halts. (E)
CAUSE
Verification of the parity generator and parity checking on the data
TLB physical page number RAM fails. Second possible
cause is the instruction unit.
ACTION
Contact your Hewlett-Packard Support Representative.
23
MESSAGE
No message. System halts. (E)
CAUSE
Verification of the parity generator and parity checking on the
instruction TLB physical page number RAM fails. Second
possible cause is the instruction unit.
ACTION
Contact your Hewlett-Packard Support Representative.
26
MESSAGE
No message. System halts. (E)
CAUSE
Verification of the memory protection trap with
byte access fails.
ACTION
Contact your Hewlett-Packard Support Representative.
27
MESSAGE
No message. System halts. (E)
CAUSE
Verification of the memory protection trap with
half word access fails.
ACTION
Contact your Hewlett-Packard Support Representative.
28
MESSAGE
No message. System halts. (E)
CAUSE
Verification of the memory protection trap with
word access fails.
ACTION
Contact your Hewlett-Packard Support Representative.
29
MESSAGE
No message. System halts. (E)
CAUSE
Verification of the instruction TLB MISS fault fails.
ACTION
Contact your Hewlett-Packard Support Representative.
2A
MESSAGE
No message. System halts. (E)
CAUSE
Cannot force data TLB MISS fault.
ACTION
Contact your Hewlett-Packard Support Representative.
2B
MESSAGE
No message. System halts. (E)
CAUSE
Cannot verify protection ID, access ID.
ACTION
Contact your Hewlett-Packard Support Representative.
2C
MESSAGE
No message. System halts. (E)
CAUSE
Cannot verify public pages.
ACTION
Contact your Hewlett-Packard Support Representative.
2D
MESSAGE
No message. System halts. (E)
CAUSE
Cannot distinguish between instruction CA and data
CA with the diagnostic register.
ACTION
Contact your Hewlett-Packard Support Representative.
2E
MESSAGE
No message. System halts. (E)
CAUSE
Verification of the two cycle opcode instruction
fails. Cannot verify TLB FREZ.
ACTION
Contact your Hewlett-Packard Support Representative.
31
MESSAGE
No message. System halts. (E)
CAUSE
Unexpected instruction TLB MISS fault occurs. Second possible
cause of the error is the instruction unit.
ACTION
Contact your Hewlett-Packard Support Representative.
32
MESSAGE
No message. System halts. (E)
CAUSE
Unexpected instruction memory protection trap occurs. Second
possible cause of the error is the instruction unit.
ACTION
Contact your Hewlett-Packard Support Representative.
33
MESSAGE
No message. System halts. (E)
CAUSE
Unexpected TLB MISS trap occurs. Second possible
cause of the error is the instruction unit.
ACTION
contact your Hewlett-Packard Support Representative.
34
MESSAGE
No message. System halts. (E)
CAUSE
Unexpected nonaccess instruction TLB MISS trap occurs. Second
possible cause of the error is the instruction unit.
ACTION
Contact your Hewlett-Packard Support Representative.
35
MESSAGE
No message. System halts. (E)
CAUSE
Unexpected nonaccess instruction TLB MISS trap occurs. Second
possible cause of the error is the instruction unit
ACTION
Contact your Hewlett-Packard Support Representative.
36
MESSAGE
No message. System halts. (E)
CAUSE
Unexpected data memory protection trap occurs. Second possible
cause of the error is the instruction unit.
ACTION
Contact your Hewlett-Packard Support Representative.
37
MESSAGE
No message. System halts. (E)
CAUSE
Unexpected data memory break trap occurs. Second possible
cause of the error is the instruction unit.
ACTION
Contact your Hewlett-Packard Support Representative.
38
MESSAGE
No message. System halts. (E)
CAUSE
Unexpected TLB dirty bit fault occurs. Second possible cause
of the error is the instruction unit.
ACTION
Contact your Hewlett-Packard Support Representative.
39
MESSAGE
No message. System halts. (E)
CAUSE
Unexpected virtual device reference trap occurs.
Second possible cause of the error is the instruction unit.
ACTION
Contact your Hewlett-Packard Support Representative.
40
MESSAGE
No message. System halts. (E)
CAUSE
Cannot verify the TLB indexing through its RAM.
ACTION
Contact your Hewlett-Packard Support Representative.
Cache Failure
cache messages take the form:
27xx
where:
xx = detailed error number.
Cache Messages 00 - CC
00
MESSAGE
No message. System halts. (E)
CAUSE
Undefined error has occurred at the start of the
test of this board.
ACTION
Contact your Hewlett-Packard Support Representative.
01
MESSAGE
No message. System halts. (E)
CAUSE
Verification of the read/write protocol in the first
and last set of data cache RAM fails.
ACTION
Contact your Hewlett-Packard Support Representative.
03
MESSAGE
No message. System halts. (E)
CAUSE
Verification of the read or write address test operation
on data cache fails. Second possible cause of the error is memory.
Third possible cause of the error is the TLB.
ACTION
Contact your Hewlett-Packard Support Representative.
04
MESSAGE
No message. System halts. (E)
CAUSE
Verification of the read or write (data path test
operation) on the data cache fails. Second possible cause of the
error is memory.
ACTION
Contact your Hewlett-Packard Support Representative.
05
MESSAGE
No message. System halts. (E)
CAUSE
Verification of the half word or byte operation on the data cache
fails. Second possible cause of the error is the register
file unit. Third possible cause of the error is memory.
ACTION
Contact your Hewlett-Packard Support Representative.
06
MESSAGE
No message. System halts. (E)
CAUSE
data cache cannot set enable interrupt request register (EIRR) bits.
Second possible cause of the error is the register file unit.
ACTION
Contact your Hewlett-Packard Support Representative.
07
MESSAGE
No message. System halts. (E)
CAUSE
Verification of the data cache dirty bit, miss or flush operation
fails. Second possible cause of the error is the register
file unit. Third possible cause of the error is memory.
ACTION
Contact your Hewlett-Packard Support Representative.
08
MESSAGE
No message. System halts. (E)
CAUSE
Verification of the data cache load word operation with clean MISS
fails. Second possible cause of the error is memory.
ACTION
Contact your Hewlett-Packard Support Representative.
0A
MESSAGE
No message. System halts. (E)
CAUSE
Verification of the parity error generator on byte
zero fails. Second possible cause of the error is memory.
ACTION
Contact your Hewlett-Packard Support Representative.
0B
MESSAGE
No message. System halts. (E)
CAUSE
Verification of the parity error generator on byte
one fails. Second possible cause of the error is memory.
ACTION
Contact your Hewlett-Packard Support Representative.
0C
MESSAGE
No message. System halts. (E)
CAUSE
Verification of the parity error generator on byte
two fails. Second possible cause of the error is memory.
ACTION
Contact your Hewlett-Packard Support Representative.
0D
MESSAGE
No message. System halts. (E)
CAUSE
Verification of the parity error generator on byte
three fails. Second possible cause of the error is memory.
ACTION
Contact your Hewlett-Packard Support Representative.
0F
MESSAGE
No message. System halts. (E)
CAUSE
cache diagnostic register bit is stuck.
ACTION
Remove floating-point board, then reboot the system. Contact
your Hewlett-Packard Support Representative.
10
MESSAGE
No message. System halts. (E)
CAUSE
Failure while verifying data path on the instruction
cache. Second possible cause of error is the execution unit..
ACTION
Contact your Hewlett-Packard Support Representative.
15
MESSAGE
No message. System halts. (E)
CAUSE
Size of I_CA and D_CA do not match (check revision
of execution unit.) Second possible cause of the error is the execution
unit.
ACTION
Contact your Hewlett-Packard Support Representative.
16
MESSAGE
No message. System halts. (E)
CAUSE
Cache line gets updated on data TLB MISS fault.
ACTION
Contact your Hewlett-Packard Support Representative.
17
MESSAGE
No message. System halts. (E)
CAUSE
Memory line gets updated on data TLB MISS fault.
ACTION
Contact your Hewlett-Packard Support Representative.
18
MESSAGE
No message. System halts. (E)
CAUSE
Failure while verifying byte transaction with data
cache MISS.
ACTION
Contact your Hewlett-Packard Support Representative.
19
MESSAGE
No message. System halts. (E)
CAUSE
Failure while verifying half word transaction with
data cache MISS.
ACTION
Contact your Hewlett-Packard Support Representative.
1A
MESSAGE
No message. System halts. (E)
CAUSE
Failure while verifying parity checking/generator
with EIRR/CMD.
ACTION
Contact your Hewlett-Packard Support Representative.
1B
MESSAGE
No message. System halts. (E)
CAUSE
cache line gets updated on TLB data trap.
ACTION
Contact your Hewlett-Packard Support Representative.
1C
MESSAGE
No message. System halts. (E)
CAUSE
memory gets updated on TLB data trap.
ACTION
Contact your Hewlett-Packard Support Representative.
20
MESSAGE
No message. System halts. (E)
CAUSE
Failure while verifying cache tag parity error.
ACTION
Contact your Hewlett-Packard Support Representative.
21
MESSAGE
No message. System halts. (E)
CAUSE
Failure while verifying EIRR/CMD with its address.
ACTION
Contact your Hewlett-Packard Support Representative.
22
MESSAGE
No message. System halts. (E)
CAUSE
Failure while verifying soft reset with its address.
ACTION
Contact your Hewlett-Packard Support Representative.
23
MESSAGE
No message. System halts. (E)
CAUSE
Failure while verifying operation of LDCWS instruction.
ACTION
Contact your Hewlett-Packard Support Representative.
24
MESSAGE
No message. System halts. (E)
CAUSE
Failure while verifying semaphore in load word and clear.
ACTION
Contact your Hewlett-Packard Support Representative.
25
MESSAGE
No message. System halts. (E)
CAUSE
Failure while verifying operation of cache MISS.
ACTION
Contact your Hewlett-Packard Support Representative.
26
MESSAGE
No message. System halts. (E)
CAUSE
Failure while verifying operation of cache FREZ.
ACTION
Contact your Hewlett-Packard Support Representative.
C7
MESSAGE
No message. System halts. (E)
CAUSE
Macrocode detects possible failure of RAM7 U1301.
ACTION
Remove Floating-Point board then reboot the system. Contact
your Hewlett-Packard Support Representative.
CA
MESSAGE
No message. System halts. (E)
CAUSE
An error occurs during a series of arbitrary microcode calculations.
Areas of possible cause are the mapper PROM or the math chips.
ACTION
Remove floating-point board then reboot the system. Contact
your Hewlett-Packard Support Representative.
CC
MESSAGE
No message. System halts. (E)
CAUSE
An error occurs which slows the execution of the floating-point
unit.
ACTION
Remove floating-point board, then reboot the system. Contact your
Hewlett-Packard Support Representative.
Class Error 3 System Monitor Card Failure
System monitor card messages take the form:
30xx
where:
xx = detailed error number.
Class 3 Errors 00 - 28
00
MESSAGE
No message. System halts. (E)
CAUSE
Undefined error occurs at the start of the test of this
board.
ACTION
Contact your Hewlett-Packard Support Representative.
01
MESSAGE
No message. System halts. (E)
CAUSE
data error occurs while verifying byte 10c (hex) of nonvolatile
memory (NVM).
ACTION
Contact your Hewlett-Packard Support Representative.
02
MESSAGE
No message. System halts. (E)
CAUSE
General register 0 is not zero at transfer of control (TOC).
ACTION
Contact your Hewlett-Packard Support Representative.
03
MESSAGE
No message. System halts. (E)
CAUSE
Invalid return address received for TOC. Second
possible cause of the error is memory.
ACTION
Contact your Hewlett-Packard Support Representative.
Contact your Hewlett-Packard Support Representative.
08
MESSAGE
No message. System halts. (E)
CAUSE
Cannot find second part of self-test in PDC PROM.
PDC PROM not installed.
ACTION
Contact your Hewlett-Packard Support Representative.
09
MESSAGE
No message. System halts. (E)
CAUSE
Cannot find PDC code in PDC PROM.
ACTION
check PDC PROM. Contact your Hewlett-Packard Support
Representative.
0A
MESSAGE
No message. System halts. (E)
CAUSE
Cannot initialize memory with switch 3 open.
ACTION
Try booting with switch 3 in normal position. Contact
your Hewlett-Packard Support Representative.
0B
MESSAGE
No message. System halts. (E)
CAUSE
General register 0 is not found to be zero at TOC
or HPMC save state routine.
ACTION
Contact your Hewlett-Packard Support Representative.
0C
MESSAGE
No message. System halts. (E)
CAUSE
Undefined error message occurs for HPMC in HPMC
save state routine.
ACTION
Contact your Hewlett-Packard Support Representative.
0D
MESSAGE
No message. System halts. (E)
CAUSE
Cannot verify checksum while downloading code from EPROM
on system monitor card.
ACTION
Contact your Hewlett-Packard Support Representative.
0E
MESSAGE
No message. System boots. (W)
CAUSE
Self-test completes with warning.
ACTION
check warning message(s). Contact your HP Representative
if future problem occurs.
0F
MESSAGE
No message. System boots. (I)
CAUSE
Self-test completes successfully.
21
MESSAGE
No message. Self-test continues. (W)
CAUSE
Verification of stable storage fails.
ACTION
Contact your HP Representative if system halt occurs
or future problem encountered.
22
MESSAGE
No message. Self-test continues. (W)
CAUSE
Failure occurs while reading from stable storage.
ACTION
Contact your HP Support Representative if system
halt occurs or future problem encountered.
28
MESSAGE
No message. Self-test continues. (W)
CAUSE
Failure occurs while reading from time-of-day clock.
ACTION
Contact your HP Support Representative if system
halt occurs or future problem encountered. check time-of-day entry
during START routine.
Class Error 4 Coprocessor Failure
Coprocessor messages take the form:
42xx
where:
xx = the last two digits of the hex display.
Class 4 Errors 00 - CC
00
MESSAGE
No message. System halts. (E)
CAUSE
Error indicates that the coprocessor is frozen.
ACTION
Contact your Hewlett-Packard Support Representative. Remove
the floating-point board, then reboot the system.
02
MESSAGE
No message. System halts. (E)
CAUSE
Test fails as single load followed by a single store
is executed without an intervening I-cache miss.
ACTION
Contact your Hewlett-Packard Support Representative. Remove
the floating-point board, then reboot the system.
03
MESSAGE
No message. System halts. (E)
CAUSE
Test fails as double load followed by a double store
is executed to see that the lower word returns correctly.
ACTION
Contact your Hewlett-Packard Support Representative. Remove
the floating-point board, then reboot the system.
04
MESSAGE
No message. System halts. (E)
CAUSE
Test fails as floating-point operation is executed
and followed by a sufficient number of nonfloating-point instructions
to ensure that the FP operation has been completed. A single-precision
store performs the check of the result.
ACTION
Contact your Hewlett-Packard Support Representative. Remove
the floating-point board, then reboot the system.
05
MESSAGE
No message. System halts. (E)
CAUSE
An error occurs as a floating-point compare operation
that sets the C bit is executed. An FTEST instruction checks that
the C bit has been set.
ACTION
Contact your Hewlett-Packard Support Representative. Remove
the floating-point board, then reboot the system.
06
MESSAGE
No message. System halts. (E)
CAUSE
An error occurs as a load of the status register
is attempted from an I/O address. This should abort.
ACTION
Contact your Hewlett-Packard Support Representative. Remove
the floating-point board, then reboot the system.
07
MESSAGE
No message. System halts. (E)
CAUSE
An error occurs as a coprocessor load followed by a floating-point
operation that uses the load data is executed.
ACTION
Contact your Hewlett-Packard Support Representative. Remove
the floating-point board, then reboot the system.
08
MESSAGE
No message. System halts. (E)
CAUSE
An error occurs since a floating-point operation that causes a
trapping exception is immediately followed by a coprocessor store with
a T-register conflict. This store should have been delayed until the
trap completes, reflecting the result of the trap.
ACTION
Contact your Hewlett-Packard Support Representative. Remove
the floating-point board, then reboot the system.
09
MESSAGE
No message. System halts. (E)
CAUSE
An unanticipated trap occurs, possibly caused by
a failure of the r1 comparator or trap logic.
ACTION
Contact your Hewlett-Packard Support Representative. Remove
the floating-point board, then reboot the system.
0A
MESSAGE
No message. System halts. (E)
CAUSE
Test of conflict comparator fails.
ACTION
Contact your Hewlett-Packard Support Representative. Remove
the floating-point board, then reboot the system.
0B
MESSAGE
No message. System halts. (E)
CAUSE
An error occurs as coprocessor load of a nonzero number to FPR (0),
the status register, is executed and then a floating-point operation
that requires zero as an operand is executed. This tests that the FP
operation reflects an operand of zero.
ACTION
Contact your Hewlett-Packard Support Representative. Remove
the floating-point board, then reboot the system.
0C
MESSAGE
No message. System halts. (E)
CAUSE
T-bit of FPR(0) is not set.
ACTION
Contact your Hewlett-Packard Support Representative. Remove
the floating-point board, then reboot the system.
0D
MESSAGE
No message. System halts. (E)
CAUSE
An error occurs as a floating-point operation with a zero T-field is
executed followed by a coprocessor store of the status register.
The status register should not have been affected by the
FP operation.
ACTION
Contact your Hewlett-Packard Support Representative. Remove
the floating-point board, then reboot the system.
0E
MESSAGE
No message. System halts. (E)
CAUSE
An error occurs as a coprocessor load to a reserved register is
attempted. This should cause a reserved operation trap.
ACTION
Contact your Hewlett-Packard Support Representative. Remove
the floating-point board, then reboot the system.
0F
MESSAGE
No message. System halts. (E)
CAUSE
An error occurs as a coprocessor load from an I/O
address is attempted. This load should abort.
ACTION
Contact your Hewlett-Packard Support Representative.
31
MESSAGE
No message. System halts. (E)
CAUSE
Test results in an unexpected assist exception trap.
This cause can stem from a variety of problems in the system, possibly
resulting from a test of the conflict comparator. This test can
also reflect a malfunction of one or more of the math chips.
ACTION
Contact your Hewlett-Packard Support Representative. Remove
the floating-point board, then reboot the system.
42
MESSAGE
No message. System halts. (E)
CAUSE
Test of ALUZERO condition fails.
ACTION
Contact your Hewlett-Packard Support Representative. Remove
the floating-point board, then reboot the system.
43
MESSAGE
No message. System halts. (E)
CAUSE
Test of ALUZERO condition fails.
ACTION
Contact your Hewlett-Packard Support Representative. Remove
the floating-point board, then reboot the system.
44
MESSAGE
No message. System halts. (E)
CAUSE
Test of ALUSIGN condition fails.
ACTION
Contact your Hewlett-Packard Support Representative. Remove
the floating-point board, then reboot the system.
45
MESSAGE
No message. System halts. (E)
CAUSE
Test of XOR in ALU fails.
ACTION
Contact your Hewlett-Packard Support Representative. Remove
the floating-point board, then reboot the system.
46
MESSAGE
No message. System halts. (E)
CAUSE
Test of AND in ALU fails.
ACTION
Contact your Hewlett-Packard Support Representative. Remove
the floating-point board, then reboot the system.
47
MESSAGE
No message. System halts. (E)
CAUSE
Test of OR in ALU fails.
ACTION
Contact your Hewlett-Packard Support Representative. Remove
the floating-point board, then reboot the system.
48
MESSAGE
No message. System halts. (E)
CAUSE
Test of load to status register fails.
ACTION
Contact your Hewlett-Packard Support Representative. Remove
the floating-point board, then reboot the system.
49
MESSAGE
No message. System halts. (E)
CAUSE
Test of instruction register fails.
ACTION
Contact your Hewlett-Packard Support Representative. Remove
the floating-point board, then reboot the system.
62
MESSAGE
No message. System halts. (E)
CAUSE
Detect failure of multiply chip U2302.
ACTION
Contact your Hewlett-Packard Support Representative. Remove
the floating-point board, then reboot the system.
64
MESSAGE
No message. System halts. (E)
CAUSE
Detect failure of add chip U2104.
ACTION
Contact your Hewlett-Packard Support Representative. Remove
the floating-point board, then reboot the system.
65
MESSAGE
No message. System halts. (E)
CAUSE
Detect failure of divide chip U2305.
ACTION
Contact your Hewlett-Packard Support Representative. Remove
the floating-point board, then reboot the system.
80
MESSAGE
No message. System halts. (E)
CAUSE
Detect failure in nullify generation circuitry.
ACTION
Contact your Hewlett-Packard Support Representative. Remove
the floating-point board, then reboot the system.
86
MESSAGE
No message. System halts. (E)
CAUSE
Microcode detects possible failure of RAM6 U1101.
ACTION
Contact your Hewlett-Packard Support Representative. Remove
the floating-point board, then reboot the system.
90
MESSAGE
No message. System halts. (E)
CAUSE
Microcode detects possible failure of RAM7 U1301.
ACTION
Contact your Hewlett-Packard Support Representative. Remove
the floating-point board, then reboot the system.
91
MESSAGE
No message. System halts. (E)
CAUSE
Microcode detects possible failure of RAM2 U1302.
ACTION
Contact your Hewlett-Packard Support Representative. Remove
the floating-point board, then reboot the system.
95
MESSAGE
No message. System halts. (E)
CAUSE
Microcode detects possible failure of RAM5 U1401.
ACTION
Contact your Hewlett-Packard Support Representative. Remove
the floating-point board, then reboot the system.
96
MESSAGE
No message. System halts. (E)
CAUSE
Microcode detects possible failure of RAM1 U1402.
ACTION
Contact your Hewlett-Packard Support Representative. Remove
the floating-point board, then reboot the system.
97
MESSAGE
No message. System halts. (E)
CAUSE
Microcode detects possible failure of RAM4 U1403.
ACTION
Contact your Hewlett-Packard Support Representative. Remove
the floating-point board, then reboot the system.
98
MESSAGE
No message. System halts. (E)
CAUSE
Microcode detects possible failure of RAM0 U1404.
ACTION
Contact your Hewlett-Packard Support Representative. Remove
the floating-point board, then reboot the system.
C0
MESSAGE
No message. System halts. (E)
CAUSE
Macrocode detects possible failure of RAM0 U1404.
ACTION
Contact your Hewlett-Packard Support Representative. Remove
the floating-point board, then reboot the system.
C1
MESSAGE
No message. System halts. (E)
CAUSE
Macrocode detects possible failure of RAM1 U1402.
ACTION
Contact your Hewlett-Packard Support Representative. Remove
the floating-point board, then reboot the system.
C2
MESSAGE
No message. System halts. (E)
CAUSE
Macrocode detects possible failure of RAM2 U1302.
ACTION
Contact your Hewlett-Packard Support Representative. Remove
the floating-point board, then reboot the system.
C3
MESSAGE
No message. System halts. (E)
CAUSE
Macrocode detects possible failure of RAM3 U1303.
ACTION
Contact your Hewlett-Packard Support Representative. Remove
the floating-point board, then reboot the system.
C4
MESSAGE
No message. System halts. (E)
CAUSE
Macrocode detects possible failure of RAM4 U1403.
ACTION
Contact your Hewlett-Packard Support Representative. Remove
the floating-point board, then reboot the system.
C5
MESSAGE
No message. System halts. (E)
CAUSE
Macrocode detects possible failure of RAM5 U1401.
ACTION
Contact your Hewlett-Packard Support Representative. Remove
the floating-point board, then reboot the system.
C6
MESSAGE
No message. System halts. (E)
CAUSE
Macrocode detects possible failure of RAM6 U1101.
ACTION
Contact your Hewlett-Packard Support Representative. Remove
the floating-point board, then reboot the system.
C7
MESSAGE
No message. System halts. (E)
CAUSE
Macrocode detects possible failure of RAM7 U1301.
ACTION
Contact your Hewlett-Packard Support Representative. Remove
the floating-point board, then reboot the system.
CA
MESSAGE
No message. System halts. (E)
CAUSE
An error occurs during a series of arbitrary microcode calculations.
Areas of possible cause are the mapper PROM or the math chips.
ACTION
Contact your Hewlett-Packard Support Representative. Remove
the floating-point board, then reboot the system.
CC
MESSAGE
No message. System halts. (E)
CAUSE
An error occurs which slows the execution of the floating-point
unit.
ACTION
Contact your Hewlett-Packard Support Representative. Remove
the floating-point board, then reboot the system.
Class Error 5 Bus Protocol Failure
Bus protocol messages takes the form:
5sxx
where:
s = slot number
xx = detailed error number.
Class 5 Errors 00 - 00
00
MESSAGE
No message. System halts. (E)
CAUSE
Undefined error occurs at the start of this test.
ACTION
Contact your Hewlett-Packard Support Representative.
Class Error 7 Memory Failure
Class Error 7 memory error messages takes the form:
7sxx
where:
s = slot number
xx = detailed error number.
NOTE: The memory test takes about 1.5 seconds per MB of memory.
Class 7 Errors 00 - 2F
00
MESSAGE
No message. System halts. (E)
CAUSE
Undefined error occurs at the start of the test of this
board.
ACTION
Contact your Hewlett-Packard Support Representative.
01
MESSAGE
No message. System halts. (E)
CAUSE
Either stuck bit occurs in I/O status register or
cannot find four contiguous words within the first 256 KB without
a single bit error.
ACTION
Contact your Hewlett-Packard Support Representative.
02
MESSAGE
No message. System halts. (E)
CAUSE
Verification of the memory with its address fails. Second possible
cause of the error is the cache unit. Third possible cause
of the error is the TLB.
ACTION
Contact your Hewlett-Packard Support Representative.
03
MESSAGE
No message. System halts. (E)
CAUSE
Pattern testing memory fails. Second possible cause
of the error is the cache unit. Third possible cause of the error
is the TLB.
ACTION
Contact your Hewlett-Packard Support Representative.
04
MESSAGE
No message. System halts. (E)
CAUSE
Multiple bit error flag is set by single bit error.
Second possible cause of the error is the cache unit.
ACTION
Contact your Hewlett-Packard Support Representative.
05
MESSAGE
No message. System halts. (E)
CAUSE
Multiple bit error flag is not set by multiple bit
error. Second possible cause of the error is the cache unit.
ACTION
Contact your Hewlett-Packard Support Representative.
06
MESSAGE
No message. System halts. (E)
CAUSE
Memory controller cannot calculate the address of the faulty memory.
Second possible cause of the error is the cache unit.
ACTION
Contact your Hewlett-Packard Support Representative.
07
MESSAGE
No message. System halts. (E)
CAUSE
Single bit error is detected. Second possible cause
of the error is the cache unit.
ACTION
Contact your Hewlett-Packard Support Representative.
0A
MESSAGE
No message. System halts. (E)
CAUSE
Parity checking/generator is not working. Second
possible cause of the error is the cache unit.
ACTION
Contact your Hewlett-Packard Support Representative.
0B
MESSAGE
No message. System halts. (E)
CAUSE
Verification of read/write protocol fails. Second
possible cause of the error is the cache unit.
ACTION
Contact your Hewlett-Packard Support Representative.
0C
MESSAGE
No message. System halts. (E)
CAUSE
Verification of read and Clear protocol fails. Second possible
cause of the error is the cache unit.
ACTION
Contact your Hewlett-Packard Support Representative.
10
MESSAGE
No message. System halts. (E)
CAUSE
Undefined type of memory controller is found.
ACTION
Contact your Hewlett-Packard Support Representative.
11
MESSAGE
No message. System halts. (E)
CAUSE
Error occurs as "hole" in memory is detected.
ACTION
Install 32 MB memory controller. Contact your Hewlett-Packard
Support Representative.
12
MESSAGE
No message. System halts. (E)
CAUSE
Last memory controller does not have a memory array
installed.
ACTION
Contact your Hewlett-Packard Support Representative. Install
memory array.
13
MESSAGE
No message. System halts. (E)
CAUSE
Last 8 MB (3 MB MC and 5 MB MA) memory controller does
not have a memory array installed.
ACTION
Contact your Hewlett-Packard Support Representative. Install
memory array.
2F
MESSAGE
No message. System halts. (E)
CAUSE
No memory board is found during initialization.
Second possible cause of the error is the cache unit.
ACTION
Contact your Hewlett-Packard Support Representative.
Class Error 8 Channel Adapter Test
Channel adapter test messages take the form:
8sxx
where:
s = slot number
xx = detailed error number.
NOTE: The channel adapter test takes about 5 seconds to perform.
Class 8 Errors 00 - 50
00
MESSAGE
No message. System halts. (E)
CAUSE
Undefined error occurs at the start of the test of this
board.
ACTION
Contact your Hewlett-Packard Support Representative.
01
MESSAGE
No message. System halts. (E)
CAUSE
Cannot enable soft physical address. (Cannot set the SSET
bit.)
ACTION
Contact your Hewlett-Packard Support Representative.
02
MESSAGE
No message. System halts. (E)
CAUSE
Cannot disable soft physical address. (Cannot reset SSET bit to
zero.)
ACTION
Contact your Hewlett-Packard Support Representative.
03
MESSAGE
No message. System halts. (E)
CAUSE
Cannot verify memory with its address.
ACTION
Contact your Hewlett-Packard Support Representative.
04
MESSAGE
No message. System halts. (E)
CAUSE
Cannot verify memory with sliding ones.
ACTION
Contact your Hewlett-Packard Support Representative.
05
MESSAGE
No message. System halts. (E)
CAUSE
Cannot verify memory with sliding zeros.
ACTION
Contact your Hewlett-Packard Support Representative.
06
MESSAGE
No message. System halts. (E)
CAUSE
Cannot verify memory with all zeros.
ACTION
Contact your Hewlett-Packard Support Representative.
07
MESSAGE
No message. System halts. (E)
CAUSE
Pattern testing of external interrupt enable mask register
fails.
ACTION
Contact your Hewlett-Packard Support Representative.
08
MESSAGE
No message. System halts. (E)
CAUSE
Cannot set interrupt register to zero.
ACTION
Contact your Hewlett-Packard Support Representative.
09
MESSAGE
No message. System halts. (E)
CAUSE
Pattern testing of interrupt register fails.
ACTION
Contact your Hewlett-Packard Support Representative.
0A
MESSAGE
No message. System halts. (E)
CAUSE
Pattern testing of chain RAM base register fails.
ACTION
Contact your Hewlett-Packard Support Representative.
0B
MESSAGE
No message. System halts. (E)
CAUSE
Failure encountered while pattern testing mask register.
ACTION
Contact your Hewlett-Packard Support Representative.
0E
MESSAGE
No message. System halts. (E)
CAUSE
Pattern testing of reset address register fails.
ACTION
Contact your Hewlett-Packard Support Representative.
0F
MESSAGE
No message. System halts. (E)
CAUSE
Pattern testing of reset data register fails.
ACTION
Contact your Hewlett-Packard Support Representative.
10
MESSAGE
No message. System halts. (E)
CAUSE
Reset does not clear soft physical address (SPA).
ACTION
Contact your Hewlett-Packard Support Representative.
11
MESSAGE
No message. System halts. (E)
CAUSE
Either a channel I/O card is not installed, or none
of the CIO cards pass the self-test and are ready for command.
ACTION
Contact your Hewlett-Packard Support Representative.
12
MESSAGE
No message. System halts. (E)
CAUSE
Stop command does not set the ready (RDY) bit.
ACTION
Contact your Hewlett-Packard Support Representative.
13
MESSAGE
No message. System halts. (E)
CAUSE
Chain command does not clear the RDY bit.
ACTION
Contact your Hewlett-Packard Support Representative.
14
MESSAGE
No message. System halts. (E)
CAUSE
Cannot get an interrupt at the end of DMA. (Appropriate bit
in submask register not set.)
ACTION
Contact your Hewlett-Packard Support Representative.
15
MESSAGE
No message. System halts. (E)
CAUSE
DMA does not transfer data.
ACTION
Contact your Hewlett-Packard Support Representative.
16
MESSAGE
No message. System halts. (E)
CAUSE
RDY bit is not set at the end of DMA.
ACTION
Contact your Hewlett-Packard Support Representative.
17
MESSAGE
No message. System halts. (E)
CAUSE
CIO card returns wrong status after the subchannel
is disconnected.
ACTION
Contact your Hewlett-Packard Support Representative.
18
MESSAGE
No message. System halts. (E)
CAUSE
Undefined error occurs with a CIO card. RFC, PST,
PRE, or LVI do not match.
ACTION
Contact your Hewlett-Packard Support Representative.
1A
MESSAGE
No message. System halts. (E)
CAUSE
Hewlett-Packard IB loopback test reports data write status
error.
ACTION
Contact your Hewlett-Packard Support Representative.
1B
MESSAGE
No message. System halts. (E)
CAUSE
Hewlett-Packard IB cannot get ready for command.
ACTION
Contact your Hewlett-Packard Support Representative.
1C
MESSAGE
No message. System halts. (E)
CAUSE
Hewlett-Packard IB loopback test reports undefined status
error.
ACTION
Contact your Hewlett-Packard Support Representative.
1D
MESSAGE
No message. System halts. (E)
CAUSE
Hewlett-Packard IB loopback test reports data error.
ACTION
Contact your Hewlett-Packard Support Representative.
1E
MESSAGE
No message. System halts. (E)
CAUSE
Channel does not request attention after disconnecting
the subchannel.
ACTION
Contact your Hewlett-Packard Support Representative.
20
MESSAGE
No message. System halts. (E)
CAUSE
Cannot verify link to previous link status block.
ACTION
Contact your Hewlett-Packard Support Representative.
21
MESSAGE
No message. System halts. (E)
CAUSE
Status error occurs while verifying link status quad.
ACTION
Contact your Hewlett-Packard Support Representative.
22
MESSAGE
No message. System halts. (E)
CAUSE
Cannot verify link to last data quad.
ACTION
Contact your Hewlett-Packard Support Representative.
23
MESSAGE
No message. System halts. (E)
CAUSE
Cannot verify counter within the DMA chain quad.
ACTION
Contact your Hewlett-Packard Support Representative.
25
MESSAGE
No message. System halts. (E)
CAUSE
Verification of channel with semaphore set to zero operation
fails.
ACTION
Contact your Hewlett-Packard Support Representative.
26
MESSAGE
No message. System halts. (E)
CAUSE
Undefined error occurs. Cannot find any installed memory
board.
ACTION
Contact your Hewlett-Packard Support Representative.
27
MESSAGE
No message. System halts. (E)
CAUSE
Verification of channel with semaphore fails. Semaphore changes
from zero to one.
ACTION
Contact your Hewlett-Packard Support Representative.
28
MESSAGE
No message. System halts. (E)
CAUSE
Verification of the parity checking operation fails.
ACTION
Contact your Hewlett-Packard Support Representative.
29
MESSAGE
No message. System halts. (E)
CAUSE
Verification of the ME bit functionality on channel
adapter status register for data parity errors fails. Channel does not
set ME bit on data parity error.
ACTION
Contact your Hewlett-Packard Support Representative.
2A
MESSAGE
No message. System halts. (E)
CAUSE
Channel cannot identify a data parity error. (Wrong MSTAT
issued on error.)
ACTION
Contact your Hewlett-Packard Support Representative.
2B
MESSAGE
No message. System halts. (E)
CAUSE
Verification of the ME bit functionality on channel
adapter status register for address parity errors fails. (Channel does
not set ME bit on error.)
ACTION
Contact your Hewlett-Packard Support Representative.
2C
MESSAGE
No message. System halts. (E)
CAUSE
Channel cannot identify an address parity error.
ACTION
Contact your Hewlett-Packard Support Representative.
2F
MESSAGE
No message. System halts. (E)
CAUSE
A mid-bus I/O card is not found.
ACTION
Contact your Hewlett-Packard Support Representative.
40
MESSAGE
No message. System halts. (E)
CAUSE
Channel cannot finish logchannel transaction. There
is no interrupt at the end of the transaction.
ACTION
Contact your Hewlett-Packard Support Representative.
41
MESSAGE
No message. System halts. (E)
CAUSE
Logchannel status error occurs. The transaction
requires the device adapter to be the system controller, and it
is not.
ACTION
Check Hewlett-Packard IB card switch setting. Contact your
Hewlett-Packard Support Representative.
42
MESSAGE
No message. System halts. (E)
CAUSE
Undefined logchannel status error occurs.
ACTION
Contact your Hewlett-Packard Support Representative.
43
MESSAGE
No message. System halts. (E)
CAUSE
End of the Hewlett-Packard IB loopback test with logchannel
returns a bad status.
ACTION
Contact your Hewlett-Packard Support Representative.
44
MESSAGE
No message. System halts. (E)
CAUSE
Subchannel is not readied after the logchannel operation.
ACTION
Contact your Hewlett-Packard Support Representative.
45
MESSAGE
No message. System halts. (E)
CAUSE
Subchannel is not readied after attention request
enable followed by an attention request operation.
ACTION
Contact your Hewlett-Packard Support Representative.
46
MESSAGE
No message. System halts. (E)
CAUSE
I/O card returns wrong status after an attention request.
ACTION
Contact your Hewlett-Packard Support Representative.
47
MESSAGE
No message. System halts. (E)
CAUSE
Correct bit is not set in the attention request register.
ACTION
Contact your Hewlett-Packard Support Representative.
48
MESSAGE
No message. System halts. (E)
CAUSE
Attention request bit set prior to attention request test.
(Error unknown.)
ACTION
Contact your Hewlett-Packard Support Representative.
49
MESSAGE
No message. System halts. (E)
CAUSE
Subchannel does not request attention after enabling attention
request and request attention. (write control of ARE and RQA.)
ACTION
Contact your Hewlett-Packard Support Representative.
4F
MESSAGE
No message. Self-test continues. (W)
CAUSE
Channel cannot complete its test without a Hewlett-Packard
IB card.
ACTION
check device adapters. Contact your Hewlett-Packard Support
Representative if device problems occur.
50
MESSAGE
No message. System halts. (E)
CAUSE
Cannot verify I/O test checksum.
ACTION
Contact your Hewlett-Packard Support Representative.
Class Error 9 Console Path Test
Class Error 9 Console path related errors and/or channel I/O errors take
the following multiplexed code form:
01wx
9yzz
where:
w = CIO slot number (<> C)
x = Device address (always 0 for the console)
y = CIO mid-bus slot number
zz = IODC driver error code 00 - 7F.
Class 9 Errors 0100 - 01C0
01009y80
MESSAGE
None.(I)
CAUSE
I/O dependent code (IODC) from channel I/O bus (CIO)
in console path fails.
ACTION
None. If problem recurs or is suspected cause of a future system
problem or failure, contact your Hewlett Packard Support
Representative.
01009y88
MESSAGE
No message. System halts. (E)
CAUSE
No working console is found. Autoboot disabled.
ACTION
Connect console or replace existing console. Reboot system.
01C09yzz
MESSAGE
No message. Self-test continues. (W)
CAUSE
Access port self-test fails. "zz" = AP self-test code
(00-7F).
ACTION
If AP not functional, reset the system from the
front panel. If a soft reset/transfer of control is needed, set
switch 3 on the system monitor card to the open position and reset
the system from the front panel. If AP is functional and can reset
the system, note the error as a possible console path or CIO bus
problem should a future problem or system failure occur.
01C09yF0
MESSAGE
No message. Self-test continues. (W)
CAUSE
Access port read of the hexadecimal display fails.
ACTION
None. Note error should a future system problem occur.
01C09yFF
MESSAGE
No message. Self-test continues. (W)
CAUSE
No access port is found.
ACTION
If an access port exists and remains functional,
note error should the problem cause a future problem or system failure.
If AP is disabled or not functioning and you have reset the system
from the front panel, ignore warning message.
Reading the Message and Code Display
Chapter 9 System Startup, Shutdown, and Configuration (cont)