- 2
- MESSAGE
GET_TIMER/GET_TIMER_IN_TICKS failed to get a new timer entry
from TABLE MANAGEMENT.
- CAUSE
All timer entries have been allocated.
- ACTION
Take a system dump.
- 3
- MESSAGE
A soft interrupt occurred during wait for a
timeout.
- CAUSE
Pause received status from extend_receive.
- ACTION
Pause will retry the timer.
- 11
- MESSAGE
The status of the timer entry is NOTIFICATION IN PROGRESS (doing
SEND_MSG).
- CAUSE
Timer interrupt handler has already sent notification
message.
- ACTION
None needed.
- 12
- MESSAGE
The status of the timer entry is non-active.
- CAUSE
Release of a timer which is dormant.
- ACTION
None needed.
- 13
- MESSAGE
A soft interrupt occurred during pause.
- CAUSE
Pause received status from extend_receive.
- ACTION
Pause will retry.
- 1002
- MESSAGE
PDC read time of day call returned with an error; the option is
nonexistent.
- CAUSE
Same as message content.
- ACTION
Take a system dump.
- 1003
- MESSAGE
PDC read time of day call returned with an error; the time of
day is invalid.
- CAUSE
Clock hardware uninitialized.
- ACTION
Initialize hardware clock.
- 1010
- MESSAGE
PDC read time of day call returned with an error; the parameter
is invalid.
- CAUSE
Same as message content.
- ACTION
Take a system dump.
- 1102
- MESSAGE
PDC set time of day call returned with an error; the option is
nonexistent.
- CAUSE
Same as message content.
- ACTION
Take a system dump.
- 1103
- MESSAGE
PDC set time of day call returned with an error; the time of day
is invalid.
- CAUSE
Same as message content.
- ACTION
Take a system dump.
- 1110
- MESSAGE
PDC set time of day call returned with an error; the parameter
is invalid.
- CAUSE
Same as message content.
- ACTION
Take a system dump.
- 1202
- MESSAGE
PDC timer call (read calib. and acc.) returned with an error;
the option is nonexistent.
- CAUSE
Same as message content.
- ACTION
Take a system dump.
- 1203
- MESSAGE
PDC timer call (read calib. and acc.) returned with an error;
the time of day is invalid.
- CAUSE
Same as message content.
- ACTION
Take a system dump.
- 1210
- MESSAGE
PDC timer call (read calib. and acc.) returned with an error;
the parameter is invalid.
- CAUSE
Same as message content.
- ACTION
Take a system dump.
- 2002
- MESSAGE
PDC READ stable storage call returned with an error; the option
is nonexistent.
- CAUSE
Same as message content.
- ACTION
Take a system dump.
- 2003
- MESSAGE
PDC READ stable storage call returned with an error; can not
complete call without error.
- CAUSE
Same as message content.
- ACTION
Take a system dump.
- 2004
- MESSAGE
PDC READ stable storage call returned with an error; the stable
storage address is invalid.
- CAUSE
Same as message content.
- ACTION
Take a system dump.
- 2005
- MESSAGE
PDC READ stable storage call returned with an error; the stable
storage contents are invalid.
- CAUSE
Same as message content.
- ACTION
Take a system dump.
- 2010
- MESSAGE
PDC READ stable storage call returned with an error; the
parameter is invalid.
- CAUSE
Same as message content.
- ACTION
Take a system dump.
- 2102
- MESSAGE
PDC WRITE stable storage call returned with an error; the
option is nonexistent.
- CAUSE
Same as message content.
- ACTION
Take a system dump.
- 2103
- MESSAGE
PDC WRITE stable storage call returned with an error; cannot
complete call without error.
- CAUSE
Same as message content.
- ACTION
Take a system dump.
- 2104
- MESSAGE
PDC WRITE stable storage call returned with an error; the stable
storage address is invalid.
- CAUSE
Same as message content.
- ACTION
Take a system dump.
- 2105
- MESSAGE
PDC WRITE stable storage call returned with an error; the stable
storage contents are invalid.
- CAUSE
Same as message content.
- ACTION
Take a system dump.
- 2110
- MESSAGE
PDC WRITE stable storage call returned with an error; the
parameter is invalid.
- CAUSE
Same as message content.
- ACTION
Take a system dump.
|