MESSAGE: None

Level: 1 CLAS0002

CAUSE: Attempt to open file NFCAT2 failed. Logging entry will also contain a file system error.

ACTION: Act according to the file system error. For example, if the error is "non-existent permanent file", then the system manager should place a copy of NFCAT2 in NET.SYS.



MESSAGE: None

Level: 10 CLAS0002

CAUSE: Attempt to open file NFTCAT2 failed. Logging entry will also contain a file system error.

ACTION: Act according to the file system error. For example, if the error is "non-existent permanent file", then the system manager should place a copy of NFTCAT2 in NET.SYS.



MESSAGE: None

Level: 6 CLAS0003

CAUSE: NFTCAT2 contains invalid configuration values.

ACTION: System manager should obtain a version of NFTCAT2 that has valid configuration values and install it in NET.SYS. Another resource is to change the configuration values in the existing NFTCAT2 file. However, Hewlett-Packard does not recommend this procedure. If any other internal errors (CLAS0000) are logged for the NFT module of the Network Services subsystem, see Appendix A “Submitting an SR ” of this manual.



MESSAGE: None

Level: 10 CLAS0003

CAUSE: Incompatible version of NFTCAT2 installed.

ACTION: System manager should obtain correct version of NFTCAT2 and install it in NET.SYS.