MESSAGE: None

Level: 8 CLAS0002

CAUSE: SYSTEM reached maximum allowable limit of NFT servers. Limit is set by the NSCONTROL command. Users request servers with the DSCOPY command or the DSCOPY intrinsic.

ACTION: Wait until fewer DSCOPY applications are running on the system. Try again. Or ask the system manager to raise the limit of allowable NFT servers (via NSCONTROL). If any other internal errors (CLAS0000) are logged for the DSUTIL module of the Network Services subsystem, see Appendix A “Submitting an SR ” of this manual.