HPlogo MPE/iX Error Messages Manual Volume III: 900 Series HP 3000 Computer Systems > Chapter 11 Distributed Terminal Subsystems

Validation Error Messages

» 

Technical documentation

Complete book in PDF
» Feedback

 » Table of Contents

The network management configuration file must be validated before it can be processed by SYSGEN. The validation procedure is invoked in NMMGR by requesting it on the VALIDATE CONFIGURATION FILE screen. Error messages will be displayed on the system console. Additionally, error messages can be directed to a printer. The DTS validation procedure starts by displaying the following on the system console:

197 - Validation of DTS/LINK started. -

Errors are then listed to the console. When the validation procedure is complete, it will print the following on the system console:

nnn Encountered Errors

NOTE: After successful validation, run SYSGEN to cross-validate the DTS configuration with the System configuration.

197 - Validation of DTS/LINK finished. -

where nnn is the total number of errors found during validation. Following is a numerical list of validation error messages and actions for each.

1

MESSAGE

Path: NMMGRpath.

A read error encountered while reading the data record (bad file). (DTSERR=1)

CAUSE

Either a hardware problem occurred or the data record is too long.

ACTION

Try to print the network management configuration file. Rebuild the file from a copy of the sample file NMSAMP1.PUB.SYS. If the problem persists, contact your Hewlett-Packard support representative.

2

MESSAGE

Path: NMMGRpath.

A write error encountered while updating the data record (bad file). (DTSERR=2)

CAUSE

Either a hardware problem occurred or the data record file is too small.

ACTION

If the data record file has been compressed, it is impossible to validate the file. Go to the UTILITY screen and use the compression utility to make the file larger. Try to validate the file. If it still fails, build the file from a copy of the sample file NMSAMP1.PUB.SYS. If the problem persists when verifying the new file, contact your Hewlett-Packard support representative.

3

MESSAGE

Path: NMMGRpath

The data record is empty (use Update Data function key). (DTSERR=3)

CAUSE

The data record was not created for the NMMGRpath.

ACTION

Go back to the screen specified by the NMMGRpath, update the screen, and press Update Data.

4

MESSAGE

Path: NMMGRpath

The same physical path is being used at LINK.linkname. (DTSERR=4)

CAUSE

The physical path specified for this link is being used.

ACTION

Go to the link screen specified by the NMMGRpath or go to the link screen specified by the linkname, and modify the physical path.

5

MESSAGE

Path: NMMGRpath

The same station address is being used at LINK.linkname. (DTSERR=5)

CAUSE

The IEEE 802.3 station address is already used. Each station address must be unique.

ACTION

Go back to the screen specified by the NMMGRpath or go to the screen specified by the linkname and modify the station address.

6

MESSAGE

Path: NMMGRpath

LINK.linkname is not defined. (DTSERR=6)

CAUSE

The link name specified on the DTS DATACOMM & TERMINAL CONTROLLER CONFIGURATION screen is not defined; therefore, the link data record was not created.

ACTION

Verify the link name on the DTS DATACOMM & TERMINAL CONTROLLER CONFIGURATION screen. Check that the link name exists on the LINK SELECTION screen and if it does, check that the link data record was created. If the link data record does not exist, update the LINK SELECTION screen and press Update Data.

7

MESSAGE

Path: NMMGRpath

DTS.PROFILE.linkname is not defined. (DTSERR=7)

CAUSE

The linkname on the screen specified by the NMMGRpath is not defined; therefore, the profile data record does not exist.

ACTION

Check that the profile name exists on the DISTRIBUTED TERMINAL SUBSYSTEM PROFILE SELECTION screen and if it does, check that the data record for this profile was created. If the profile data record was not created, then update the linkname screen and press Update Data.

8

MESSAGE

Path: NMMGRpath

The same station address or node name is being used at DTS.DTC. SELECT.linkname. (DTSERR=8)

CAUSE

The station address or node name used on the screen specified by the NMMGRpath is also used on the screen specified by the DTS.DTC.SELECT.linkname screen.

ACTION

Go to the screen specified by the NMMGRpath or to the screen specified by the linkname and modify the station address or node name.

9

MESSAGE

Path: NMMGRpath

The same LDEV #nnn is being used at DTS.DTC.SELECT.linkname.CARD012. (DTSERR=9)

CAUSE

The logical device (ldev) number is being used on the screen specified by the NMMGRpath and on the DTS.DTC.SELECT.linkname.CARD012 screen.

ACTION

Go to one of the two screens and change the ldev number. The ldev number must be unique for each port.

10

MESSAGE

Path: NMMGRpath

The same LDEV #nnn is being used at DTS.DTC.SELECT.linkname.CARD345. (DTSERR=10)

CAUSE

The same logical device (ldev) number is being used on the screen specified by the NMMGRpath and on the DTS.DTC.SELECT.linkname.CARD345 screen.

ACTION

Go to one of the two screens and change the ldev number. The ldev number must be unique for each port.

12

MESSAGE

Path: NMMGRpath

LDEV #nnn is too big (must be ≤999). (DTSERR=12)

CAUSE

The logical device (ldev) number is bigger than the allowed maximum ldev number.

ACTION

Go to the screen specified by the NMMGRpath and modify the ldev number.

13

MESSAGE

Path: NMMGRpath

Too many LDEVs are being used (must be ≤600). (DTSERR=13)

CAUSE

Too many logical device (ldev) numbers are being used.

ACTION

Visit the screens that use ldevs and delete some ldev numbers. The validation procedure allows a total of 600 ldevs.

15

MESSAGE

Path: NMMGRpath

Defined LINK. linkname is not being used. (DTSWARN15)

CAUSE

The defined linkname is not used by DTS or the network interface.

ACTION

This is a warning only. No action is required.

16

MESSAGE

Path: NMMGRpath

Too many links are being used (max. number allowed = 8). (DTSERR=16)

CAUSE

The link specified in the NMMGRpath cannot be processed. Too many links are already defined.

ACTION

Go back to the LINK SELECTION screen and delete the link specified in the NMMGRpath. Delete all unused links so that eight or less links are being used.

17

MESSAGE

Path: NMMGRpath

Too many paths are being used (max. number allowed = 8). (DTSERR=17)

CAUSE

The link specified in the NMMGRpath cannot be processed. Too many physical paths are already defined.

ACTION

Go back to the LINK SELECTION screen and delete the link specified in the NMMGRpath. Delete all unused links so that eight or less links are being used.

18

MESSAGE

Path: NMMGRpath

Too many DTCs are being used (max. number allowed = 24). (DTSERR=18)

CAUSE

The DTC specified in the NMMGRpath cannot be processed. Too many DTCs are already configured.

ACTION

Go back to the DTC SELECTION screen and delete the DTC specified in the NMMGRpath.

19

MESSAGE

Path: NMMGRpath

Too many nodes are being used (max. number allowed = 33). (DTSERR=19)

CAUSE

The DTC specified in the NMMGRpath cannot be processed. Too many nodes are being used.

ACTION

Go to the DTC SELECTION screen and delete the DTC specified in the NMMGRpath.

20

MESSAGE

Path: NMMGRpath

Too many classes are being used (max. number allowed = 450). (DTSERR=20)

CAUSE

The total number of classes exceeds the maximum allowed number.

ACTION

Delete class names so that no more than 450 different class names are associated with asynchronous devices.

21

MESSAGE

Path: NMMGRpath

Too many profiles are being used (max. number allowed = 100). (DTSERR=21)

CAUSE

The total number of defined profiles exceeds the maximum allowed.

ACTION

Delete profiles so that no more than 100 are specified.

22

MESSAGE

No link is defined. (DTSWARN=22)

CAUSE

A link is not configured.

ACTION

Without a configured link, the network management configuration file is useless. Return to the configuration screens and add a link, making sure that all necessary data records are created.

23

MESSAGE

No DTC is defined. (DTSWARN=23)

CAUSE

A DTC is not configured.

ACTION

An action is not required if neither terminals, printers, nor both are needed. If terminals and printers are required, return to the configuration screens and add a DTC, making sure that all necessary data records are created.

24

MESSAGE

Path: NMMGRpath

LINK.linkname is shared with network interface. (DTSWARN=24)

CAUSE

The same link is shared between the DTS and the NS subsystem. A separate link must exist for each of the two subsystems.

ACTION

Decide which of the two subsystems should use the existing link and configure an additional link for the remaining subsystem.

25

MESSAGE

Path: NMMGRpath

Modem type not supported. (DTSERR=25)

CAUSE

The modem type specified on the DTS TERMINAL PROFILE screen is not 0, 1, or 2.

ACTION

Modify the modem type specified on the DTS TERMINAL PROFILE screen to specify the appropriate modem type. Press Update Data.

27

MESSAGE

Path: NMMGRpath

Must supply a physical path. (DTSERR=27)

CAUSE

A physical path was not specified in the Physical Path IEEE 802.3 Device Adapter field.

ACTION

Go the IEEE 802.3 LINK CONFIGURATION screen and enter the appropriate physical path. Press Update Data.

28

MESSAGE

Path: NMMGRpath

Duplicate profile class name linkname used. (DTSWARN=28)

CAUSE

The same class name is used in a terminal profile or a printer profile.

ACTION

Remove the duplicate class name from the printer profile or the terminal profile.

29

MESSAGE

Path: NMMGRpath

Class name duplicated between printer and terminal profiles. (DTSERR=29)

CAUSE

The same class name is used for both a terminal profile and a printer profile.

ACTION

Remove the duplicate class name from the terminal profile or the printer profile.

30

MESSAGE

Path: NMMGRpath

Profile specified for non-nailed terminals is of printer-type. (DTSERR=30)

CAUSE

A printer profile is specified where only a terminal profile is allowed.

ACTION

Change the printer profile to be a terminal profile.

31

MESSAGE

Path: NMMGRpath

Profile linkname specified for non-nailed PAD terminals is of Printer-type. (DTSERR=31)

CAUSE

A printer profile is specified where only a terminal profile is allowed.

ACTION

Change the printer profile to be a terminal profile.

32

MESSAGE

Path: NMMGRpath

PAD device name for LDev #nnn is being used at DTS.DTCPC.SELECT.linkname.CARD012.PAD0. (DTSERR=32)

CAUSE

A PAD name is used more than once.

ACTION

Remove all of the duplicate references to the PAD name.

33

MESSAGE

Path: NMMGRpath

PAD device name for LDev #nnn is being used at DTS.DTCPC.SELECT.linkname .CARD012.PAD1. (DTSERR=33)

CAUSE

A PAD name is used more than once.

ACTION

Remove all of the duplicate references to the PAD name.

34

MESSAGE

Path: NMMGRpath

PAD device name for LDev #nnn is being used at DTS.DTCPC.SELECT.linkname .CARD012.PAD2. (DTSERR=34)

CAUSE

A PAD name is used more than once.

ACTION

Remove all of the duplicate references to the PAD name.

35

MESSAGE

Path: NMMGRpath

PAD device name for LDev #nnn is being used at DTS.DTCPC.SELECT.linkname .CARD345.PAD3. (DTSERR=35)

CAUSE

A PAD name is used more than once.

ACTION

Remove all of the duplicate references to the PAD name.

36

MESSAGE

Path: NMMGRpath

PAD device name for LDev #nnn is being used at DTS.DTCPC.SELECT.linkname .CARD345.PAD4. (DTSERR=36)

CAUSE

A PAD name is used more than once.

ACTION

Remove all of the duplicate references to the PAD name.

37

MESSAGE

Path: NMMGRpath

PAD device name for LDev #nnn is being used at DTS.DTCPC.SELECT.linkname .CARD345.PAD5. (DTSERR=37)

CAUSE

A PAD name is used more than once.

ACTION

Remove all of the duplicate references to the PAD name.

38

MESSAGE

Path: NMMGRpath

The same LDEV #nnn is being used at DTS.DTCPC.SELECT.linkname.CARD 012.PAD0. (DTSERR=38)

CAUSE

The same logical device (ldev) number is used more than once.

ACTION

Remove the duplicate ldev number.

39

MESSAGE

Path: NMMGRpath

The same LDEV #nnn is being used at DTS.DTCPC.SELECT.linkname .CARD012.PAD1. (DTSERR=39)

CAUSE

The same logical device (ldev) number is used more than once.

ACTION

Remove the duplicate ldev number.

40

MESSAGE

Path: NMMGRpath

The same LDEV #nnn is being used at DTS.DTCPC.SELECT.linkname .CARD012.PAD2. (DTSERR=40)

CAUSE

The same logical device (ldev) number is used more than once.

ACTION

Remove the duplicate ldev number.

41

MESSAGE

Path: NMMGRpath

The same LDEV #nnn is being used at DTS.DTCPC.SELECT.linkname .CARD345.PAD3. (DTSERR=41)

CAUSE

The same logical device number (ldev) is used more than once.

ACTION

Remove the duplicate ldev number.

42

MESSAGE

Path: NMMGRpath

The same LDEV #nnn is being used at DTS.DTCPC.SELECT.linkname .CARD345.PAD4. (DTSERR=42)

CAUSE

The same logical device (ldev) number is used more than once.

ACTION

Remove the duplicate ldev number.

43

MESSAGE

Path: NMMGRpath

The same LDEV #nnn is being used at DTS.DTCPC.SELECT.linkname .CARD345.PAD5. (DTSERR=43)

CAUSE

The same logical device (ldev) number is used more than once.

ACTION

Remove duplicate ldev number.

44

MESSAGE

Path: NMMGRpath

The same LDEV #nnn is being used at DTS.DTCPC.SELECT.linkname .CARD012.(DTSERR=44)

CAUSE

The logical device (ldev) number is used more than once in the CARD012 configuration.

ACTION

Remove any duplicate references to the ldev number.

45

MESSAGE

Path: NMMGRpath

The same LDEV #nnn is being used at DTS.DTCPC.SELECT.linkname .CARD345.(DTSERR=45)

CAUSE

The logical device (ldev) number is used more than once in the CARD345 configuration.

ACTION

Remove any duplicate references to the ldev number.

46

MESSAGE

Path: NMMGRpath

The same node name is being used at linkname. (DTSERR=46)

CAUSE

The same node name is used more than once.

ACTION

Remove the duplicate reference to the node name.

47

MESSAGE

Path: NMMGRpath

Blank node name. (DTSERR=47)

CAUSE

A host node name is not specified on the screen specified in the path.

ACTION

Enter a host node name on the screen specified in the path.

Feedback to webmaster