MESSAGE

The code segment number is invalid.

CAUSE

The caller passed in a code segment which is invalid for the process whose PIN was passed in, or the code segment is unassigned.

ACTION

None.

30

MESSAGE

The data segment number is invalid.

CAUSE

The caller passed in an invalid or an unassigned data segment number.

ACTION

None.

60

MESSAGE

FREEZE returned a bad status.

CAUSE

The memory manager failed to freeze a compatibility mode code or data segment into memory.

ACTION

Examine the process error stack to determine what may have caused the problem.

65

MESSAGE

UNFREEZE returned a bad status.

CAUSE

The memory manager failed to unfreeze a compatibility mode code or data segment into memory.

ACTION

Examine the process error stack to determine what may have caused the problem.

160

MESSAGE

SWITCH_TO_CM returned a bad status.

CAUSE

Corruption of an operating system data structure or operating system code caused SWITCH_TO_CM to fail.

ACTION

Examine the process error stack to determine what may have caused the problem.

301

MESSAGE

The logical device parameter is not a real device.

CAUSE

An attempt was made to place a non-existent device or a spooler virtual device into diagnostic mode.

ACTION

None.

302

MESSAGE

The device is currently not in diagnostic mode.

CAUSE

An attempt was made to remove a device not owned by the diagnostic system from the diagnostic mode.

ACTION

None.

304

MESSAGE

The device is already in diagnostic mode.

CAUSE

An attempt was made to place a device which was already owned by the diagnostic system into the diagnostic mode.

ACTION

None.

305

MESSAGE

The device is currently in use.

CAUSE

An attempt was made to place a device currently being accessed by a user into the diagnostic mode.

ACTION

Try again once the user is no longer accessing the device. The SHOWDEV command can be used to determine the current owner.

309

MESSAGE

The spooler for the device could not be stopped.

CAUSE

While attempting to place a device into the diagnostic mode, the system could not stop the spooler active on the device.

ACTION

Use the STOPSPOOL command to stop the spooler. If sucessful, attemp the diagnostic again.

311

MESSAGE

The spooler for the device could not be restarted.

CAUSE

While removing the device from the diagnostic mode, the system could not restart a spooler for the device.

ACTION

If desired, use the STARTSPOOL command on the console to start a spooler for the device.

312

MESSAGE

The spooler for the device could not be suspended.

CAUSE

While attempting to place a device into diagnostic mode, the system could not suspend the currently active spoolfile.

ACTION

Try using the SUSPENDSPOOL command on the console to suspend the currently active spoolfile.

320

MESSAGE

The logical console cannot be placed in diagnostic mode.

CAUSE

An attempt was made to place the logical console into diagnostic mode.

ACTION

Move the logical console to another terminal using the CONSOLE command.

321

MESSAGE

Disks cannot be placed in diagnostic mode.

CAUSE

An attempt was made to place a disk into diagnostic mode.

ACTION

None.

2550

MESSAGE

GETSIR returned a bad status to the fast switch stub.

CAUSE

Corruption of an operating system data structure or operating system code caused GETSIR to fail.

ACTION

Perform a system dump. Reboot the system using START.

2551

MESSAGE

RELSIR returned a bad status to the fast switch stub.

CAUSE

Corruption of an operating system data structure or operating system code caused RELSIR to fail.

ACTION

Perform a system dump. Reboot the system using START.