HPlogo MPE/iX Error Messages Manual Volume III: 900 Series HP 3000 Computer Systems > Chapter 7 CM Emulator & OCT

(Subsystem 188)

» 

Technical documentation

Complete book in PDF
» Feedback

 » Table of Contents

1

MESSAGE

The input node is too low. (CMNODES ERROR 1)

CAUSE

Bad input parameter.

ACTION

No harm done. Function returns false.

2

MESSAGE

The input node is too high. (CMNODES ERROR 2)

CAUSE

Bad input parameter.

ACTION

No harm done. Function returns false.

3

MESSAGE

Invalid node return from debug. (CMNODES ERROR 3)

CAUSE

Bad input parameter.

ACTION

No harm done. Function returns false.

201

MESSAGE

The code segment loaded emulated because translation is bad.

CAUSE

Bad translation.

ACTION

Retranslate with a good OCT.

202

MESSAGE

The code segment loaded emulated because translation is bad.

CAUSE

Bad translation.

ACTION

Retranslate with a good OCT.

203

MESSAGE

The code segment loaded emulated because OCT is for another system.

CAUSE

The system and OCT versions are not compatible.

ACTION

Retranslate with the appropriate OCT version.

204

MESSAGE

The code segment loaded emulated because translation is bad.

CAUSE

Bad translation.

ACTION

Retranslate with a good OCT.

205

MESSAGE

The code segment loaded emulated because FFILEINFO failed.

CAUSE

Unknown.

ACTION

Call your Hewlett-Packard Representative.

501

MESSAGE

OCT error occurred.

502

MESSAGE

! is an invalid code segment name.

503

MESSAGE

! is an invalid code segment number.

504

MESSAGE

Failed to open file !.

505

MESSAGE

! is an invalid input file.

506

MESSAGE

! is an unknown argument name.

507

MESSAGE

Argument ! is specified in an invalid manner.

508

MESSAGE

Attempt to read beyond PB.

510

MESSAGE

PLABEL ! is out of bounds.

550

MESSAGE

OCT internal error occurred.

CAUSE

Internal error.

ACTION

Call your Hewlett-Packard Representative.

551

MESSAGE

An error occurred executing CI command.

552

MESSAGE

Invalid addressing mode.

553

MESSAGE

Invalid data type on stack.

554

MESSAGE

Double operand missing HOLE-REG.

555

MESSAGE

The maximum register usage has been exceeded.

556

MESSAGE

An invalid register is specified.

557

MESSAGE

Trap entry was not made.

558

MESSAGE

Unable to decode CM instruction.

559

MESSAGE

A TEMP REG has been clobbered.

560

MESSAGE

Trap entry was made but not PUT.

561

MESSAGE

An undefined block label is specified.

562

MESSAGE

An unknown INST type was encountered.

563

MESSAGE

An invalid BRANCH target is specified.