To run NMMGRVER, logon as MANAGER.SYS in the PUB group and run the utility by entering NMMGRVER after the MPE/iX prompt. NMMGRVER will prompt you for the configuration file name. Enter NMCONFIG, and Y to the confirmation prompt.

The steps to run NMMGRVER are shown here:

 

: HELLO MANAGER.SYS,PUB

: NMMGRVER

NM Configuration File Conversion Utility 32098-20016 
B.04.07 (C) Hewlett-Packard Co. 1988

Utility to convert NM configuration files to be 
compatible with NMMGR B.04.07.

****************************************************
****************************************************
* BE SURE TO STORE BACK UP *
* Copies of Config Files BEFORE Conversion *
****************************************************
****************************************************

Fileset to scanned? NMCONFIG
OK to convert NMCONFG? Y
Backup file is NMBACKn; temporary file is Nxxxx.
** Converting MPE iX config file **

The configuration for the DTS subsystem has been
updated. If this file will be used as NMCONFIG.PUB.SYS,
you must restart the DTS subsystem for the
configuration to take effect. (NMMGRVERMSG 102)

CONVERSION completed successfully. (NMMGRVERMSG 0)

NMMGRVER generates a backup copy of you old configuration file under file name NMBACKn, (where n starts with A, then B, C, and so on, for multiple backup copies). It also creates a temporary file Nxxxx, that is purged upon completion of NMMGRVER conversion.

After converting the network configuration file with NMMGRVER, you then run NMMGR if needed to modify the DTS subsystem to fit your actual hardware configuration. Follow the steps described in Chapter 5 “Configuring Serial Devices (for Host-Based Management)” for modifying you network configuration file.

NOTE: After converting your network configuration file with NMMGRVER, you must validate and cross-validate NMCONFIG.PUB.SYS inside NMMGR and reboot you HP 3000 system. Refer to Chapter 5 “Configuring Serial Devices (for Host-Based Management)” for details on these steps.