HPlogo HP SNA Products Remote System Configuration Guide: HP 3000 MPE/iX Computer Systems > Chapter 2 JES Configuration

SNA NRJE/V and SNA NRJE/iX Configuration

» 

Technical documentation

Complete book in PDF
» Feedback

 » Table of Contents

 » Index

JES2 Requirements (SNA NRJE)

The JES2 configuration consists of defining the remote workstation to JES2 in a configuration file. JES2 requires (either specifically or by default) that the following information be defined for each workstation:

  • JES2 global parameters

  • LINEnnnn--line definition

  • RMTnnnn--remote workstation definition

  • Rnnnn.PRm--remote printer definition

  • Rnnnn.PUm--remote punch definition

  • Rnnnn.RDm--remote reader definition

Table 2-1 contains the parameters and values required by Hewlett-Packard for SNA NRJE for JES2 version 4.1 and earlier versions. For programmers experienced in configuring 8100 DPPX/RJE workstations and 3770 workstations, the table provides most of the needed information. For more information, see the parameter descriptions at the end of this chapter.

Table 2-1 SNA NRJE: JES2 Parameters

Pre-version 4.1 ParametersVersion 4.1 ParametersComments
LINEnnnn macro  
   
UNIT=SNAUNIT=SNARequired.
   
RMTnnnn macro  
   
LUTYPE1DEVTYPE=LUTYPE1Required.
LUNAMELUNAMEDo NOT specify.
BUFSIZE=256 orBUFSIZE=256 or 
BUFSIZE=512 BUFSIZE=512Required.
CONSOLECONS=YESRequired.
NOCMPCTCOMPACT=NORequired.
NUMRDRNUMRDRRequired (specify from 1-7).
SETUPHDRSETUP=PDIRRequired.
SETUPINF SETUPINFLOCAL190=INFORequired.
WAITIME=1WAITIME=1Required.
   
Rnnnn.PRm macro  
   
AUTO Required for Ver. 1.3.2 and earlier.
CCTLCCTL=YESRequired.
CMPCT/NOCMPCTCOMPACT=NO/YESDo NOT specify.
COMP/NOCOMPCOMPRESS=NO/YESDo NOT specify.
STARTSTART=YESRequired.
FCBLOAD/NOFCBLOADFCBLOAD=YES/NODo NOT specify.
LRECLLRECLIf specified, must be between 40 and 255.
PRWIDTHPRWIDTHRequired (value must be between 40 and 255).
SELECTSELECTDo NOT specify.
SEPSEPRequired.
UCS=OUCS=ORequired.
Rnnnn.PUm macro  
   
AUTO Required for Ver. 1.3.3 and earlier.
CCTLCCTL=YESRequired.
CMPCT/NOCMPCTCMPCT=YES/NODo NOT specify.
COMP/NOCOMPCOMPRESS=YES/NODo NOT specify.
STARTSTART=YESRequired.
SELECTSELECTDo NOT specify.
SEPSEPRequired.
   
Rnnnn.RDm macro  
   
STARTSTARTRequired.

 

JES3 Requirements (SNA NRJE)

The JES3 configuration consists of defining the remote workstation to JES3 in a configuration file. JES3 requires (either specifically or by default) that the following information be defined for each workstation:

  • JES3 global parameters

  • CONSOLE--remote workstation console

  • DEVICE--to define printers and punches

  • RJPWS--remote workstation definition

JES3 macro and operand values for SNA NRJE should be coded as though a DPPX/RJE 8100 SNA workstation were being installed. Table 2-2 contains the parameter and values required by Hewlett-Packard for SNA NRJE. For more information, see the parameter descriptions at the end of this chapter.

Table 2-2 SNA NRJE: JES3 Parameters

ParametersComments
CONSOLE macro 
  
JNAMERequired.
TYPE=RJPRequired.
  
DEVICE macro 
  
DTYPE=RMT xxxxxRequired.
JNAMERequired.
  
RJPWS macro 
  
NRequired.
RDRequired (specify from 1-7).
C=RRequired.
COMPACT=NORequired.
AUTO=NRequired.
LUDo NOT specify.

 

VSE/POWER Requirements (SNA NRJE)

The VSE/POWER configuration consists of defining the remote workstation to VSE/POWER in a configuration file. VSE/POWER requires (either specifically or by default) that the following information be defined for each workstation:

  • VSE/POWER global parameters

  • PRMT--remote workstation definition

VSE/POWER macro and operand values for SNA NRJE should be coded as though a DPPX/RJE 8100 SNA workstation were being installed. Table 2-3 contains the parameters and values required by Hewlett-Packard for SNA NRJE. For more information, see the parameter descriptions at the end of this chapter.

Table 2-3 SNA NRJE: VSE/POWER Parameters

ParametersComments
POWERSubparameter SNA=(,,POWER) is required.
  
PRMT macro 
  
CONSOLE=YESRequired.
REMOTE REMOTERequired.
SESSLIM=6 SESSLIMRequired.
TYPE=LUT1 TYPERequired.
XLATE=NO XLATERequired.
CMPACT CMPACTDo NOT specify.
LUDo NOT specify.

 

NOTE: Parameters that are not listed in table 2-3 can be entered at your discretion. There are no restrictions on them beyond what is required for DPPX/RJE on the IBM 8100.
Feedback to webmaster