HPlogo HP SNA Products Remote System Configuration Guide: HP 3000 MPE/iX Computer Systems > Chapter 1 ACF/NCP and ACF/VTAM Configuration

MPE/iX SNA Product Configuration

» 

Technical documentation

Complete book in PDF
» Feedback

 » Table of Contents

 » Index

This section covers remote system configuration requirements for the following MPE/iX SNA products:

  • SNA/SDLC Link/iX

  • SNA/X.25 Link/iX

  • SNA/Token Ring Link/iX

  • SNA DHCF/iX

  • SNA IMF/iX

  • SNA NRJE/iX

  • LU 6.2 API/iX

  • HP SNADS/iX

This section presents the requirements for:

  • ACF/NCP and ACF/VTAM for switched and non-switched lines

  • NCP Token-Ring Interconnection (NTRI)

  • X.25 NCP Packet Switching Interface (NPSI)

  • logmode table parameters.

ACF/NCP and ACF/VTAM Requirements

The ACF/VTAM start parameters refer to the table and buffer size definitions that ACF/VTAM uses to configure the resource requirements for the network. Because start parameters apply to the entire VTAM domain and are not specific to the remote node, HP does not make any suggestions. HP does recommend that the ACF/VTAM system programmer review the defined values and make any adjustments for additional requirements put on the system.

The tables in this section contain the parameters that HP allows for its MPE/iX SNA products. Operands and values that you must specify are noted. The tables also contain other operands that are allowed. For operand definitions, refer to the section Parameter Definitions at the end of this chapter, or to the appropriate NCP or VTAM manual for the remote system.

WARNING! The HP SNA products are emulations of IBM products. Thus, some parameters will need particular values based on the requirements of the HP products. Code these as specified or results are unpredictable. Operands not listed are not allowed in the HP SNA services definitions and therefore are not supported. Any time spent solving problems related to incorrect configuration of the host is billable to the customer on a time and materials basis.

For MPE/iX SNA products, more than one PU may be defined for an HP 3000. A maximum of eight PUs can be defined for each HP 3000 with SDLC links. Multiple PUs can be defined for each HP 3000 SNA Token Ring Link. The number of PUs defined depends upon the number of SNA Link products installed.

A maximum of 255 LUs can be configured for each HP 3000 PU. For SNA NRJE/iX, it is recommended that at least three LUs be defined. SNA IMF can support a maximum of 64 LUs. The LU 6.2 products can start a maximum of eight LUs. See the MPE/iX SNA product documentation for more information on configuration requirements.

Switched Lines

Tables 1-9 and 1-10 define the parameters necessary to connect MPE/iX SNA products to a switched line. Any values listed that are not required are given as examples. See Parameter Descriptions at the end of this chapter or refer to the appropriate NCP or VTAM manual for the remote system for more information.

Table 1-9 MPE/iX SNA Products: NCP/VTAM Switched Line

Operands and ValuesComments
LUDRPOOL macro 
NUMTYPE2=nRequired by all MPE/iX SNA products.
GROUP macro 
DIAL=YESRequired by all SNA products.
LNCTL=SDLCRequired by all MPE/iX SNA products.
REPLYTO 
TEXTTO 
TYPE=NCPRequired by all MPE/iX SNA products.
LINE macro 
ADDRESS=line addrRequired by all MPE/iX SNA products.
SPEED=rateRequired by all MPE/iX SNA products.
ANSWER=ON 
CALL=INRequired by all MPE/iX SNA products.
CLOCKNG=EXTRequired by all MPE/iX SNA products.
DATRATE 
DUPLEX 
ETRATIO 
HDXSP 
INTPRI 
LPDATS 
MAXPU=1Required by all MPE/iX SNA products.
NRZI=YESAllowed for SNA NRJE/iX, SNA IMF/iX, LU 6.2 API/iX, and HP SNADS/iX.
PAUSE 
POLLED=YESRequired for ACF/NCP version 1, release 1 and 2. Invalid for ACF/NCP version 1, release 3, and later versions.
RETRIES=7 
RING 
SPDSEL 
TRANSFER 
OWNER 

 

Table 1-10 MPE/iX SNA Products: VTAMLST Switched Major Node

Operands and ValuesComments
VBUILD macro 
  
TYPE=SWNETRequired by all MPE/iX SNA products.
  
PU macro 
  
puname PURequired by all MPE/iX SNA products.
ADDR=nRequired by all MPE/iX SNA products.
ANSRequired by all MPE/iX SNA products.
IDBLK=023Required for SNA IMF/iX, SNA NRJE/iX, LU 6.2 API/iX, HP SNADS/iX, SNA DHCF/iX.
IDNUM=nRequired by all MPE/iX SNA products.
DISCNT=NO 
ISTATUS 
MAXLU 
PUTYPE=2Required by all MPE/iX SNA products.
SRT 
XID=YESRequired for PU type 2.1 (T2.1).
LU macro 
luname LURequired by all MPE/iX SNA products.
LOCADDR=nRequired by all MPE/iX SNA products. Set to 0 for independent LUs.
BATCH=YESRecommended for SNA NRJE/iX on applicable versions of ACF/NCP. This parameter is not supported for ACF/NCP version 5 or later.
DLOGMODDo not specify for SNA DHCF/iX.
ISTATUS 
MODETAB=HPMODTABDo not specify for SNA DHCF/iX.
PACING=0Recommended for SNA IMF/iX.
SSCPFM=FSSRequired for LU 6.2 API/iX, SNA NRJE/iX, HP SNADS/iX, and SNA DHCF/iX.
SSCPFM=USSSCSRequired for SNA IMF/iX.
VPACING=0Recommended for SNA IMF/iX keyboards and displays.
USSTABMust be specified for SNA IMF/iX only. Do not specify for SNA NRJE/iX, SNA DHCF/iX, or LU 6.2 products.
LOGAPPLCan be used with SNA IMF/iX only. Do not specify for SNA NRJE/iX, or SNA DHCF/iX.

 

Non-Switched Lines

Table 1-11 defines the parameters necessary to connect MPE/iX SNA products to a leased (non-switched) line. See Parameter Descriptions at the end of this chapter or refer to the appropriate NCP or VTAM manual for the remote system for more information.

Table 1-11 MPE/iX SNA Products: NCP/VTAM Non-Switched Line

Operands and ValuesComments
GROUP macro 
  
DIAL=NORequired by all MPE/iX SNA products.
LNCTL=SDLCRequired by all MPE/iX SNA products.
REPLYTO 
TEXTTO 
TYPE=NCPRequired by all MPE/iX SNA products.
  
LINE macro 
  
ADDRESS=line addrRequired by all MPE/iX SNA products.
SPEED=rateRequired by all MPE/iX SNA products.
CLOCKNG=EXTRequired by all MPE/iX SNA products.
DATRATE 
DUPLEX 
ETRATIO 
HDXSP 
INTPRI 
LPDATS 
MAXPU 
NRZI=YESAllowed for SNA NRJE/iX, SNA IMF/iX, LU 6.2 API/iX, and HP SNADS/iX.
PAUSE 
POLLED=YESRequired for ACF/NCP ver. 1, rel. 1 or 2. Invalid for ACF/NCP ver. 1, rel. 3, and later versions. 
RETRIES  
SERVLIM  
SPDSEL  
TRANSFER  
OWNER  
SERVICE macro  
   
ORDERMAXLIST 
   
PU macro  
   
puname PURequired by all MPE/iX SNA products. 
ADDR=nRequired by all MPE/iX SNA products. 
ANS  
DISCNT=NO  
IRETRY  
ISTATUS  
MAXDATA=265 or  
MAXDATA=521Required by all MPE/iX SNA products. 
MAXOUT=7PASSLIM=7 
PUTYPE=2Required by all MPE/iX SNA products. 
RETRIES=7  
SRT  
XID=YESRequired for type 2.1 node. 
LU macro  
   
luname LURequired by all MPE/iX SNA products. 
LOCADDR=nRequired by all MPE/iX SNA products. Set to 0 for independent LUs. 
BATCH=YESRecommended for SNA NRJE/iX on applicable versions of ACF/NCP. This parameter is not supported for ACF/NCP version 5 or later. 
DLOGMODDo not specify for SNA DHCF/iX. 
ISTATUS  
MODETAB=HPMODTABDo not specify for SNA DHCF/iX. 
PACING=0Recommended for SNA IMF/iX keyboards and displays. 
SSCPFM=FSSRequired for LU 6.2 API/iX, HP SNADS/iX, SNA NRJE/iX, and SNA DHCF/iX. 
SSCPFM=USSSCSRequired for SNA IMF/iX. 
VPACING=0Recommended for SNA IMF/iX keyboards and displays. 
USSTABMust be specified for SNA IMF/iX only. Do not specify for SNA NRJE/iX, SNA DHCF/iX, or LU 6.2 products. 
LOGAPPLCan be used with SNA IMF/iX only. Do not specify for SNA NRJE/iX, or LU 6.2 products. 

 

NTRI Requirements

This section defines the Network Control Program Token-Ring Interconnection (NTRI) parameters that are necessary for a successful connection between a host and MPE/iX SNA products.

The ACF/VTAM start parameters refer to the table and buffer size definitions that ACF/VTAM uses to configure the resource requirements for the network. Because start parameters apply to the whole network and are not specific to the remote node, HP does not make any suggestions. HP does recommend that the ACF/VTAM system programmer review the defined values and make any adjustments for additional requirements put on the system.

The tables in this section contain the parameters that HP allows for its MPE/iX SNA products. Operands and values that you must specify are noted. The tables also contain other operands that are allowed. For operand definitions, refer to the section Parameter Definitions at the end of this chapter, or to the appropriate NCP or VTAM manual for the remote system.

WARNING! The HP SNA products are emulations of IBM products. Thus, some parameters will need particular values based on the requirements of the HP products. Code these as specified or results are unpredictable. Operands not listed are not allowed in the HP SNA services definitions and therefore are not supported. Any time spent solving problems related to incorrect configuration of the host is billable to the customer on a time and materials basis.

NTRI Parameters

NTRI is an NCP function that allows a communications controller to be attached to an IBM Token-Ring network. NTRI provides SNA subarea and peripheral nodes with data link control services. Table 1-12 contains NTRI parameters that are defined in NCP. Table 1-13 contains the VTAM switched major node parameters for NTRI.

Table 1-12 MPE/iX SNA Products: NTRI Parameters

Operands and ValuesComments
GROUP macro (physical)ECLTYPE=(PHYSICAL,
PERIPHERAL)Required by all MPE/iX SNA products.
COMPSWP=NORequired for NCP version 5, release 2.1 and earlier.
DIAL=NO 
LNCTL=SDLCRequired by all MPE/iX SNA products.
TYPE=NCPRequired by all MPE/iX SNA products.
LINE macro 
ADAPTER=TIC1 or 
ADAPTER=TIC2Required by all MPE/iX SNA products.
ADDRESS=lnbr, FULLRequired by all MPE/iX SNA products.
PORTADD=nRequired by all MPE/iX SNA products.
LOCADD=4000abbbbbbbRequired by all MPE/iX SNA products.
RCVBUFC=nRequired by all MPE/iX SNA products.
PU macro 
puname PURequired by all MPE/iX SNA products.
LU macro 
luname LURequired by all MPE/iX SNA products.
GROUP macro (logical) 
  
ECLTYPE=(LOGICAL, 
PERIPHERAL)Required by all MPE/iX SNA products.
DIAL=YESRequired by all MPE/iX SNA products.
PHYPORT=nRequired by all MPE/iX SNA products.
  
LINE macro 
  
linename LINERequired by all MPE/iX SNA products.
  
PU macro 
  
puname LURequired by all MPE/iX SNA products.

 

NOTE: Table 1-13 contains those parameters that are added to the BUILD statement for NTRI. It does not contain all of the parameters that are necessary for a complete BUILD statement.

Table 1-13 MPE/iX SNA Products: NTRI Switched Major Node

Operands and ValuesComments
VBUILD macro 
TYPE=SWNETRequired by all MPE/iX SNA products.
  
PU macro 
puname PURequired by all MPE/iX SNA products. Must match logical PU name.
ADDR=nRequired by all MPE/iX SNA products.
ANS=CONTRequired by all MPE/iX SNA products.
IDBLK=nRequired by all MPE/iX SNA products.
IDNUM=nRequired by all MPE/iX SNA products.
DISCNT=NO 
ISTATUS=ACTIVE 
MAXDATA 
MAXLU 
PUTYPE=2Required by all MPE/iX SNA products.
SRT 
XID=YESRequired for PU type 2.1 (T2.1).
MAXDATA=nRequired by all MPE/iX SNA products.
LU macro 
luname LURequired by all MPE/iX SNA products.
LOCADDR=nRequired by all MPE/iX SNA products. Set to 0 for independent LUs.
DLOGMODDo not specify for SNA DHCF/iX.

 

X.25 NPSI Requirements

This section defines the X.25 Network Control Program Packet Switching Interface (NPSI) parameters that are necessary for a successful connection between a host and MPE/iX SNA products.

The ACF/VTAM start parameters refer to the table and buffer size definitions that ACF/VTAM uses to configure the resource requirements for the network. Because start parameters apply to the whole network and are not specific to the remote node, HP does not make any suggestions. HP does recommend that the ACF/VTAM system programmer review the defined values and make any adjustments for additional requirements put on the system.

The tables in this section contain the parameters that HP allows for its MPE/iX SNA products. Operands and values that you must specify are noted. The tables also contain other operands that are allowed. For operand definitions, refer to the section Parameter Definitions at the end of this chapter, or to the appropriate NCP or VTAM manual for the remote system.

WARNING! The HP SNA products are emulations of IBM products. Thus, some parameters will need particular values based on the requirements of the HP products. Code these as specified or results are unpredictable. Operands not listed are not allowed in the HP SNA services definitions and therefore are not supported. Any time spent solving problems related to incorrect configuration of the host is billable to the customer on a time and materials basis.

Common SVC and PVC Parameters

Tables 1-14 contains NPSI parameters that are common to both Switched Virtual Circuits (SVCs) and Permanent Virtual Circuits (PVCs).

NOTE: Table 1-14 contains those parameters that are added to the BUILD statement for X.25 NPSI. It does not contain all of the parameters that are necessary for a complete BUILD statement.

Table 1-14 MPE/iX SNA Products: Common SVC/PVC Parameters

Operands and ValuesComments
BUILD macro
 
  
   X25.MAXPIU=n
Required by all MPE/iX SNA products.
   X25.MWINDOW=7
Required by all MPE/iX SNA products.
   X25.PREFIX
 
   X25.SNAP
 
   X25.USGTIER
 
  
X25.NET macro
 
  
  CPHINDX
 
   DM
Required by all MPE/iX SNA products.
   NETTYPE
 
   OUHINDX
 
  
X25.VCCPT macro
 
  
   INDEX=index
 
   INSLOW
 
   MAXPKL=128
Required by all MPE/iX SNA products.
   VWINDOW=7
 
  
X25.MCH macro
 
  
   ADDRESS=address
Required by all MPE/iX SNA products.
   ANS=CONTINUE
 
   CONNECT=NO
Required by all MPE/iX SNA products.
   DBIT=NO
Required by all MPE/iX SNA products.
   DIRECT
 
   DSABLTO
 
   ENABLETO
 
   FRMLGTH=length
Required by all MPE/iX SNA products.
   GATE=NO
Required by all MPE/iX SNA products.
   ISTATUS
 
   ITRACE
 
   LCGDEF
Required by all MPE/iX SNA products.
   LLC3
 
   LCNO
 
   LLCLIST=LLC3
Required by all MPE/iX SNA products.
   MWINDOW
Required by all MPE/iX SNA products.
   SUBADDR
 
   NCPGRP
 
   NDRETRY
 
   NPRETRY
 
   PAD=NO
Required by all MPE/iX SNA products.
   PKTMODL=8
Required by all MPE/iX SNA products.
   PUNAME
 
   PWPROT
 
   SPAN
 
   SPEED
 
   SPNQLLC=NO
Required by all MPE/iX SNA products.
   STATION
 
   STATOPT
 
   T1TIMER
 
   TDTIMER
 
   TPTIMER
 
   VMODTAB
 
  
X25.LCG macro
 
  
   LCGN=groupnumber
Required by all MPE/iX SNA products.

 

PVC Parameters

Table 1-15 defines the NPSI parameters that are necessary to connect to a PVC. See the Parameter Descriptions at the end of this chapter or refer to the NPSI manual for the remote system for more information.

Table 1-15 MPE/iX SNA Products: PVC NPSI Parameters

Operands and ValuesComments
X25.LINE macro
 
  
   COMMITO
 
   DSTNODE=BNN
Required by all MPE/iX SNA products.
   ISTATUS
 
   LCN=nnnn
Required by all MPE/iX SNA products.
   NCPGRP
 
   RETVCCT
 
   RETVCTO
 
   SPAN
 
   STATOPT
 
   TYPE=PERMANENT
Required by all MPE/iX SNA products.
   VCCINDX
Required by all MPE/iX SNA products.
  
X25.PU macro
 
  
   ADDR=nnn
Required by all MPE/iX SNA products.
   DLOGMOD
 
   IRETRY=YES
 
   MAXDATA
 
   MAXOUT=7
 
   MODETAB=HPMODTAB
 
   PASSLIM=7
 
   PUTYPE=2
Required by all MPE/iX SNA products.
   STATUS=ACTIVE
 
   XID=YES
 
  
X25.LU macro
 
  
   LOCADDR=locaddr
Required by all MPE/iX SNA products.
   ISTATUS
 
   DLOGMOD
 

 

SVC Parameters

There are two methods that can be used to define an SVC:

  • Use the X25.LINE macro, the X25.PU macro, and the Switched Major Node parameters for SVCs.

  • Use the X25.VC macro and the Switched Major Node parameters for SVCs.

The method chosen depends upon the remote system. See the Parameter Descriptions at the end of this chapter or refer to the NPSI manual for the remote system for more information.

Table 1-16 defines the NPSI parameters that are necessary to connect to an SVC. Table 1-17 defines the Switched Major Node parameters for SVCs.

For MPE/iX SNA products, more than one PU may be defined for an HP 3000 node. A maximum of eight PUs can be defined for each HP 3000 node. The number of PUs defined depends upon the number of SNA Link products installed.

A maximum of 64 LUs can be configured for each HP 3000 PU. For SNA NRJE/V, it is recommended that at least three LUs be defined. SNA IMF can support a maximum of 64 LUs. The LU 6.2 products can start a maximum of eight LUs. See the MPE/V SNA product documentation for more information on configuration requirements.

Table 1-16 MPE/iX SNA Products: SVC NPSI Parameters

Operands and ValuesComments
X25.LINE macro
 
  
   LCN=ennn
Required by all MPE/iX SNA products.
   TYPE=SWITCHED
Required by all MPE/iX SNA products.
   OUFINDX
Required by all MPE/iX SNA products.
   LLC=LLC3
Required by all MPE/iX SNA products.
   VCCINDX=index
Required by all MPE/iX SNA products.
   CALL=IN
Required by all MPE/iX SNA products.
   DSTNODE=BNN
Required by all MPE/iX SNA products.
   COMMITO
 
   ISTATUS
 
   NCPGRP
 
   RETVCCT
 
   RETVCTO
 
   SPAN
 
   STATOPT
 
  
X25.PU macro
 
  
   PUTYPE=2
Required by all MPE/iX SNA products.
  
X25.VC macro
 
  
   LCN=nnn
Required by all MPE/iX SNA products.
   TYPE=SWITCHED
Required by all MPE/iX SNA products.
   OUFINDX=index
Required by all MPE/iX SNA products.
   VCCINDX=index
Required by all MPE/iX SNA products.
   CALL=IN
Required by all MPE/iX SNA products.
   COMMITO
 
   ISTATUS
 
   NCPGRP
 
   RETVCCT
 
   RETVCTO
 
   SPAN
 
   STATOPT
 

 

Table 1-17 MPE/iX SNA Products: SVC Switched Major Node

Operands and ValuesComments
VBUILD macro
 
  
   TYPE=SWNET
Required by all MPE/iX SNA products.
  
PU macro
 
  
   puname pu
Required by all MPE/iX SNA products.
   ANS
 
   IDBLK=023
Required for LU 6.2 API/iX, SNA NRJE/iX, and HP SNADS/iX.
   IDBLK=017
Required for SNA IMF/iX and SNA DHCF/iX IBM 3274 emulation.
   IDBLK=018
Required for SNA IMF/iX and SNA DHCF/iX IBM 3276 emulation.
   IDNUM=n
Required by all MPE/iX SNA products.
   DISCNT=NO
 
   ISTATUS
 
   MAXLU
 
   MAXDAT
 
   MAXPATH
 
   PASSLIM
 
   PUTYPE=2
Required by all MPE/iX SNA products.
   SRT
 
  
PATH macro
 
  
   USE
 
   DIALNO=[HP net addr]
 
    [IBM net addr] [pi] 
 
    [VCCINDEX] 
 
    [OUFIDX]
Required by all MPE/iX SNA products.
   GRPNM
 
   PID
 
LU macro
 
  
   luname LU
Required by all MPE/iX SNA products.
   LOCADDR=address
Required by all MPE/iX SNA products.
   BATCH=YES
Recommended for SNA NRJE/iX on applicable versions of ACF/NCP. This parameter is not supported for ACF/NCP version 5 or later.
   DLOGMOD
Do not specify for SNA DHCF/iX.
   ISTATUS
 
   MODTAB=HPMODTAB
Do not specify for SNA DHCF/iX.
   PACING=0
Specify for SNA IMF/iX.
   SSCPFM=FSS
Required by LU 6.2 API/iX, HP SNADS/iX, and SNA NRJE/iX.
   SSCPFM=USSSCS
Required by SNA IMF/iX and SNA DHCF/iX.
   VPACING=0
Recommended for SNA IMF/iX keyboards and displays.
   USSTAB
Valid for SNA IMF/iX only. Do not specify for SNA NRJE/iX, SNA DHCF/iX or LU 6.2 products.
   LOGAPPL
Valid for SNA IMF/iX only. Do not specify for SNA NRJE/iX, SNA DHCF/iX or LU 6.2 products.

 

Logmode Table Requirements

The Logmode table definitions determine the operating characteristics of the session with a host LU—the bind parameters. The tables in this section define the Logmode table parameters necessary for MPE/iX SNA products.

Tables 1-18, 1-19, and 1-20 contain Logmode table parameters required for SNA NRJE/iX for the JES2, JES3, and POWER job entry subsystems. Table 1-21 contains the Logmode table parameters required for SNA IMF/iX. Table 1-22 contains the Logmode table parameters required for SNA DHCF/iX. Table 1-23 contains the Logmode table parameters for non-SNA devices connected to HCF. Table 1-24 contains the Logmode table parameters required for the LU 6.2 products, LU 6.2 API/iX and HP SNADS/iX.

Table 1-18 SNA NRJE/iX: JES2 Logmode Table

Required ParametersValues (hexadecimal)Comments
COMPROT
7080
Required value.
FMPROF
03
Required value.
LOGMODE
MODENRJE
Suggested value.
PSNDPAC
3
Suggested value.
PRIPROT
B1 or B3
Required value.
 
B3
 
PSERVIC
01102000F100C00000010040
Suggested value.
RUSIZES[1]
8585
Required value.
SECPROT
A3
Suggested value.
SSNDPAC
3
Suggested value.
SRCVPAC
3
Suggested value.
TSPROF
03
Required value.
[1]  

[1] See Parameter Descriptions at the end of this chapter for an explanation of RUSIZES values.

 

Table 1-19 SNA NRJE/iX: JES3 Logmode Table

Required ParametersValues (hexadecimal)Comments
COMPROT
7080
Required value.
FMPROF
03
Required value.
LOGMODE
MODENRJE
Suggested value.
PSNDPAC
3
Suggested value.
PRIPROT
A1, A3, B1, or B3
Required value.
PSERVIC
01102000F100C00000010040
Suggested value.
RUSIZES[1]
8686
Required value.
SECPROT
A1 or A3
Required value.
SSNDPAC
3
Suggested value.
SRCVPAC
3
Suggested value.
TSPROF
03
Required value.
[1]  

[1] See Parameter Descriptions at the end of this chapter for an explanation of RUSIZES values.

 

Table 1-20 SNA NRJE/iX: POWER Logmode Table

Required ParametersValues (hexadecimal)Comments
COMPROT
7080
Required value.
FMPROF
03
Required value.
LOGMODE
MODENRJE
Suggested value.
PSNDPAC
3
Suggested value.
PRIPROT
A3
 
 
B3
Required value.
PSERVIC
01102000F100C00000010040
Suggested value.
RUSIZES[1]
8585
Required value.
SECPROT
A1
Required value.
SSNDPAC
3
Suggested value.
SRCVPAC
3
Suggested value.
TSPROF
03
Required value.
[1]  

[1] See Parameter Descriptions at the end of this chapter for an explanation of RUSIZES values.

 

Table 1-21 SNA IMF/iX: Logmode Table

Required ParametersValues (hexadecimal)Comments
COMPROT
3080 
Required value.
FMPROF
03
Required value.
LOGMODE
IMFLU1

for LU.T1

IMF1920

for LU.T2 with 1920 size screen

IMF480

for LU.T2 with 480 size screen

IMF3440

for LU.T2 with 3440 size screen

IMFLU3

for LU.T3

Suggested value.
PSNDPAC
3
Suggested value.
PRIPROT
11, 21, 31, A1, or B1
Required value.
PSERVIC

Printer (LU.T1):

01000000E100000000000000

Terminal (LU.T2) and screen size of 1920 (24 x 80):

020000000000000000000200
020000000000185000007E00
020000000000185018507F00

Terminal (LU.T2) and screen size of 480 (12 x 40):

0200000000000C2800007E00
0200000000000C280C287F00

Terminal (LU.T2) and screen size of 3440 (43 x 80):

0200000000002B5000007E00
0200000000002B502B507F00

Printer (LU.T3):

030000000000000000000200
Suggested value.
RUSIZES[1]

Must be 8989 or less.

8587

-LU.T1 Printer

8989

-LU.T2 Terminal

Suggested value.
SECPROT
90

(LU.T1/T3 printer),

A0

, or

 B0

(LU.T2 display station)

Required value.
SSNDPAC
3

-LU.T1 and LU.T3 printers

0

-LU.T2 terminals

Suggested value.
SRCVPAC
3
Suggested value.
TSPROF
03
Required value.
[1]  

[1] See Parameter Descriptions at the end of this chapter for an explanation of RUSIZES values.

 

NOTE: Table 1-22 shows the logmode definitions for IBM 3270 terminals. The logmode entries defined for HP 3000 LUs are not used with SNA DHCF/iX.

Table 1-22 SNA DHCF/iX: Logmode Table

Required ParametersValues (hexadecimal)Comments
COMPROT
3080
Required value.
FMPROF
03
Required value.
LOGMODE
DHCF1920 for 1920 size screenSuggested values.
 DHCF2560 for 2560 size screen
dP12D4A3278

may be used

 DHCF3440 for 3440 size screenfor Model 2 devices.
PRIPROT
B1
Required value.
PSERVIC

Screen size of 1920 (24 x 80):

020000000000185000007E00

Screen size of 2560 (32 x 80):

020000000000205000007E00

Screen size of 3440 (43 x 80):

0200000000002B5000007E00
Suggested values.
RUSIZES[1]
87C7
Suggested value.
SECPROT
90 or B0
Required value.
TSPROF
03
Required value.
[1]  

[1] The value specified must be at least 88 (hex B3B3) but no larger than 4096 (hex 8989). See Parameter Definitions at the end of this chapter for an explanation of RUSIZES values.

 

Table 1-23 Non-SNA HCF Devices: Logmode Table

Required ParametersValues (hexadecimal)Comments
COMPROT
2000
Required value.
FMPROF
02
Required value.
LOGMODE
 
D4B32782

, the standard IBM-supplied logmode entry for non-SNA or BSC Model 2 devices, may be used.

PRIPROT
71
Required value.
PSERVIC

Screen size of 1920:

000000000000185000007E00
Suggested value.
RUSIZES[1]
A8A8
Suggested value.
SECPROT
40
Required value.
TSPROF
02
Required value.
[1]  

[1] The value specified must be at least 88 (hex B3B3) but no larger than 4096 (hex 8989). See Parameter Definitions at the end of this chapter for an explanation of RUSIZES values.

 

Table 1-24 MPE/iX LU 6.2 Products: Logmode Table

Required ParametersValues (hexadecimal)Comments
LOGMODE
MODE62
Suggested value.
PSERVIC
000000000000000000000000
Suggested value.
PSNDPAC
3

for LU 6.2 API/iX

3

for HP SNADS/iX

Suggested value.
SSNDPAC
0
Suggested value.
SRCVPAC
0
Suggested value.

 

NOTE: The values in table 1-24 are for node type 2.0 (T2.0) only. For T2.1 LUs (that is, independent LUs), the actual logmode value is not important, as long as the logmode is a valid one.