HPlogo SNA NRJE Node Manager's Guide: HP 3000 MPE/iX Computer Systems > Appendix A Result Codes and Messages

Validation Messages

» 

Technical documentation

Complete book in PDF
» Feedback

 » Table of Contents

 » Glossary

 » Index

Listed below are the messages that might occur when you validate the NRJE configuration data. They are listed in numerical order according to message number. Configuration file validation is discussed in Chapter 3 “SNA NRJE Configuration” of this manual.



MESSAGE: Configuration file corrupt. Missing NRJE path. (NRJEVALERR 3)

Level: NRJEVALERR 3

CAUSE: The SNA NRJE path is missing from the configuration file.

ACTION: Create a new configuration file.



MESSAGE: Configuration file corrupt. Missing NRJE version. (NRJEVALERR 4)

Level: NRJEVALERR 4

CAUSE: No version stamp exists for the SNA NRJE path.

ACTION: Create a new configuration file.



MESSAGE: No configuration data exists for NRJE subsystem. (NRJEVALWARN 5)

Level: NRJEVALWARN 5

CAUSE: No data is configured for SNA NRJE. Note that this is a warning message.

ACTION: If you do not want SNA NRJE to be configured, no action is necessary. If you want NRJE to be configured, you must configure it before validating the configuration file again.



MESSAGE: Path: ! Path name not found. (NRJEVALERR 6)

Level: NRJEVALERR 6

CAUSE: The indicated path cannot be found in the configuration file.

ACTION: Ensure that the configuration data indicated in the path (for example, wised or writername) is correctly configured. If it is, contact your HP representative.



MESSAGE: Path: ! No data found in path record. (NRJEVALERR 7)

Level: NRJEVALERR 7

CAUSE: No data is in the record for the indicated path.

ACTION: Ensure that data is configured for the indicated path. If it is, contact your HP representative.



MESSAGE: Path: ! Node "!" is not configured under SNANODE screen. (NRJEVALERR 8)

Level: NRJEVALERR 8

CAUSE: NA node listed as a configured SNA NRJE node was not configured as an SNA node.

ACTION: Configure the indicated node as an SNA node on the SNA Node Configuration screen.



MESSAGE: Path: ! Logical device "!" is not a valid NRJE reader. (NRJEVALERR 9)

Level: NRJEVALERR 9

CAUSE: The indicated ldev is invalid for the reader indicated in the path. This usually happens when the ldev is already configured for another subsystem.

ACTION: Configure the correct ldev for the reader in the Logical Device field of the NRJE Configuration: Reader Data screen. Remember that you should not configure the same reader ldev for workstations that might be simultaneously active.



MESSAGE: Path: ! Lookup table is not configured under PAGE2 screen. (NRJEVALERR 10)

Level: NRJEVALERR 10

CAUSE: A formid is configured in the Output Destination field of the NRJE Configuration: Writer Data screen, but a lookup table is not configured in the Formid Lookup Table File field of the NRJE Configuration: Workstation Data Page 2 screen.

ACTION: If you want a lookup table to be used, ensure that a table is correctly configured on the NRJE Configuration: Workstation Data Page 2 screen. If you do not want a lookup table to be used, ensure that a formid is not configured on the NRJE Configuration: Writer Data screen.



MESSAGE: Path: ! LUs not validated. Invalid SNAnode "!". (NRJEVALWARN 11)

Level: NRJEVALWARN 11

CAUSE: This error is related to NRJEVALERR 8. If an invalid node name is specified on the NRJE Configuration: Workstation Data screen, the LUs cannot be validated. Note that this is a warning message.

ACTION: Ensure that the indicated SNA node name is correct. If it is, contact your HP representative.



MESSAGE: Path: ! LU "!" is not configured for SNAnode "!". (NRJEVALERR 12)

Level: NRJEVALERR 12

CAUSE: The indicated LU is not configured under the indicated SNA node.

ACTION: Ensure that the LU should be configured under the SNA node. If it should be configured, configure it on the SNA Configuration: PU and LU Data screen.



MESSAGE: Path: ! No writers are configured. (NRJEVALERR 13)

Level: NRJEVALERR 13

CAUSE: No writer is configured for the workstation indicated in the path.

ACTION: Configure at least one writer for the workstation on the NRJE Configuration: Writer List screen.



MESSAGE: Path: ! Logging subsystem "SUB0002" is not configured. (NRJEVALERR 14)

Level: NRJEVALERR 14

CAUSE: The logging subsystem for SNA NRJE is not configured.

ACTION: Configure the SNA NRJE logging subsystem (SUB0002) on the Logging Configuration screen.



MESSAGE: Path: ! Logging class "!" is not configured. (NRJEVALERR 15)

Level: NRJEVALERR 15

CAUSE: The indicated SNA NRJE logging class is not configured.

ACTION: Configure the indicated SNA NRJE logging class on the Logging Configuration: Logging Classes screen.



MESSAGE: Path: ! Unknown error occurred while getting this path. (NRJEVALERR 16)

Level: NRJEVALERR 16

CAUSE: An unexpected error occurred while attempting to obtain a path from the configuration file. This usually indicates a problem with the validation procedure.

ACTION: Contact your HP representative.



MESSAGE: Path: ! Unknown error occurred while reading the path data. (NRJEVALERR 17)

Level: NRJEVALERR 17

CAUSE: An unexpected error occurred while attempting to read data from the configuration file. This usually indicates a problem with the validation procedure.

ACTION: Contact your HP representative.

Feedback to webmaster