Obtains the contents of the NRJE welcome message.

Syntax

                 I       I      BA    IA    
NRJEWelcome ( MaxLen, ActLen, Msg, Result )

Parameters

MaxLen

An input integer variable. The MaxLen parameter specifies the maximum text length that can be returned in Msg.

The maximum length of the NRJE welcome message is 1912 characters. (This includes the carriage return and the line feed.)

ActLen

An output integer variable. The ActLen parameter contains the actual number of characters of the NRJE welcome message returned to you in the Msg array.

Msg

An output byte array. The Msg array contains the text of the NRJE welcome message.

Result

An eight-element integer output array (required). The Result array contains error codes that occurred during execution of this intrinsic.

The first element of the Result array is set to zero if no errors took place. The structure of the Result array is described in "Parameters Common to NRJE Intrinsics" in the introduction to this chapter.

Always test the first element of Result immediately after you call this intrinsic. If the first element of Result is not zero, test the other elements of Result to determine the nature of the problem that has occurred.

Description

NRJEWelcome is used to obtain the text of an NRJE welcome message. You must provide an array large enough to hold all of the welcome message text. Specify the message array size when you call NRJEWelcome. NRJE can accept lines up to 80 characters long and adds a carriage return and a line feed at the end of each line. The maximum total number of characters that can be included in the welcome file is 1912. The actual message length is returned by the intrinsic. When NRJEWelcome returns control to your program, you should test Result.

Text Reference

NRJE welcome messages are output immediately after the product identification banner when the subsystem command interface is used.