HP C/HP-UX Release Notes for HP-UX 11.0: HP 9000 Computers > Chapter 4 Problem Descriptions and Fixes Defect Fixes |
|
HP C/ANSI C implements enumeration types and bit fields as signed by default, as specified by the ANSI C standard. As of HP-UX 11.0, HP C/ANSI C in 64-bit mode only incorrectly implemented enumeration types and bit fields as unsigned by default. This defect has been fixed in version A.11.01.00 of HP C/ANSI C. That is, in 64-bit mode, HP C/ANSI C now correctly implements enumeration types and bit fields as signed by default. |
|