Enhanced Run Command Compatibility [ COMMUNICATOR 3000 XL, XL Release 1.1 (Core Software Release A.10.00) ] MPE/iX Communicators


COMMUNICATOR 3000 XL, XL Release 1.1 (Core Software Release A.10.00)

Enhanced Run Command Compatibility 

by Richard A. Santos, Information Software Division 

The security of the :RUN command, for native mode programs, has been
enhanced to be compatible with MPE V/E. The algorithm to grant execution
rights for a privilege mode program now also checks to make sure the
program was linked with the cap=PM option.  The new algorithm is in
contrast to only checking the capability of the group where the program
resides.

With this higher degree of compatibility it is possible to experience the
loader error:

     EXEC level of the code exceeds the maximum privilege level allowed
     in the file (LDRERR 404)

on programs which successfully executed on releases previous to XL
Release 1.1 (A.10.00).