HP 3000 Manuals

The Expert Parameters [ HP GlancePlus User's Manual (for MPE/iX Systems) ] MPE/iX 5.0 Documentation


HP GlancePlus User's Manual (for MPE/iX Systems)

The Expert Parameters 

The Expert parameters control the operation of the Expert Facility.

The EXPERT MODE parameter controls whether the Expert facility
examines the system automatically every time the display is
updated (continuous mode) or is available only after typing the
X command (on demand).

 DEFAULT:     DEMAND

 GLANCNFG:    XPERT DEMAND or XPERT CONTINUOUS

 JCW:         SETJCW GLANCEXPERT=0 (for demand) or 
              SETJCW GLANCEXPERT=1 (for continuous)

 VALUES:      XPERT CONTINUE or XPERT DEMAND

The EXPERT LEVEL parameter controls whether the Expert facility
is working at a low level of detail (no process) or at high
detail (including processes) and slightly higher overhead.  See
chapter 6 on the Expert facility for information on how to set
this parameter.

 DEFAULT:     LOW

 GLANCNFG:    XLEVEL LOW or XLEVEL HIGH

 JCW:         SETJCW GLANCELEVEL=1 (for low) or 
              SETJCW GLANCELEVEL=2 (for high)

 VALUES:      XLEVEL=LOW or HIGH



MPE/iX 5.0 Documentation