Messages 19000 - 19999 [ Information Access Server: Error Messages ] MPE/iX 5.0 Documentation
Information Access Server: Error Messages
Messages 19000 - 19999
NOTE Causes and actions are listed only when more information is
necessary. If the error message contains an MPE error number,
respond to the MPE error and try again.
--------------------------------------------------------------------------------------
AC19046 INTERNAL ERROR-Failed to open DHDPMODS.PPCUTIL.HPOFFICE, FSERR
number
Generated by: Administrator Utility
A file system error occurred during an attempt to open the file
DHDPMODS.PPCUTIL.HPOFFICE. The file contains a list of all files
for which version numbers are to be checked.
Respond to the FSERR specified.
--------------------------------------------------------------------------------------
AC19047 INTERNAL ERROR-Failed to close DHDPMODS.PPCUTIL.HPOFFICE, FSERR
number
Generated by: Administrator Utility
A file system error occurred during an attempt to close the file
DHDPMODS.PPCUTIL.HPOFFICE. The file contains a list of all files
for which version numbers are to be checked.
Respond to the FSERR specified.
--------------------------------------------------------------------------------------
AC19048 INTERNAL ERROR-Failed to open DHDPVERS.PPCSAVE.HPOFFICE, FSERR
number
Generated by: Administrator Utility
A file system error occurred during an attempt to open the file
DHDPVERS.PPCSAVE.HPOFFICE that is built by the Administrator
Utility when performing a verification operation. The file
contains a list of the version numbers for all files listed in the
file DHDPMODS.PPCUTIL.HPOFFICE.
Respond to the FSERR specified.
--------------------------------------------------------------------------------------
AC19049 INTERNAL ERROR-Failed to close DHDPVERS.PPCSAVE.HPOFFICE, FSERR
number
Generated by: Administrator Utility
A file system error occurred during an attempt to close the file
DHDPVERS.PPCSAVE.HPOFFICE that is built by the Administrator
Utility when performing a verification operation. The file
contains a list of the version numbers for all files listed in the
file DHDPMODS.PPCUTIL.HPOFFICE.
Respond to the FSERR specified.
Table 1-0. (cont.)
--------------------------------------------------------------------------------------
AC19050 ERROR-Failed to rewind DHDPVERS.PPCSAVE.HPOFFICE, FSERR number
Generated by: Administrator Utility
A file system error occurred during an attempt to point to the
beginning of the file DHDPVERS.PPCSAVE.HPOFFICE that is built by
the Administrator Utility when performing a verification
operation. The file contains a list of the version numbers for
all files listed in the file DHDPMODS.PPCUTIL.HPOFFICE.
Respond to the FSERR specified.
--------------------------------------------------------------------------------------
AC19051 INTERNAL ERROR-Failed to read a record from DHDPVERS, FSERR number
Generated by: Administrator Utility
A file system error occurred during an attempt to read from the
file DHDPVERS.PPCSAVE.HPOFFICE that is built by the Administrator
Utility when performing a verification operation. The file
contains a list of the version numbers for all files listed in the
file DHDPMODS.PPCUTIL.HPOFFICE.
Respond to the FSERR specified.
--------------------------------------------------------------------------------------
AC19080 ERROR-Information Access modules are incompatible
Generated by: Administrator Utility
The Information Access module version numbers are not all the
same. The only part of the version numbers checked for
compatibility are the V.UU.FF portion, not the 3 digit patch level
following the "FF".
Review the DHDPVERS.PPCSAVE.HPOFFICE file to find the
incompatible module(s), by comparing Information Access version
numbers. Re-install the software from the installation tape and
run the verification again.
--------------------------------------------------------------------------------------
AC19084 INTERNAL ERROR-Failed to read a module record from DHDPMODS, FSERR
number
Generated by: Administrator Utility
A file system error occurred during an attempt to read from the
file DHDPMODS.PPCUTIL.HPOFFICE. The file contains a list of all
files for which version numbers are to be checked.
Respond to the FSERR specified.
Table 1-0. (cont.)
--------------------------------------------------------------------------------------
AC19085 INTERNAL ERROR-Failed to write a version record to DHDPVERS, FSERR
number
Generated by: Administrator Utility
A file system error occurred during an attempt to write to the
file DHDPVERS.PPCSAVE.HPOFFICE that is built by the Administrator
Utility when performing a verification operation. The file
contains a list of the version numbers for all files listed in the
file DHDPMODS.PPCUTIL.HPOFFICE.
Respond to the FSERR specified.
--------------------------------------------------------------------------------------
AC19086 INTERNAL ERROR-Unknown module type name encountered in DHDPMODS
Generated by: Administrator Utility
An unknown module type was found when reading from the file
DHDPMODS.PPCUTIL.HPOFFICE. The file contains a list of all files
for which version numbers are to be checked.
Store a copy of the file in case it needs to be examined by your
HP representative. Call your HP representative.
--------------------------------------------------------------------------------------
AC19087 ERROR-name can't get version num from file, FSERR number
Generated by: Administrator Utility
A file system error occurred during an attempt to get the version
number from the user label of a file that is to be verified.
Respond to the file system error. FOPEN error 92 indicates that
the file being verified has a lockword. FOPEN error 52 indicates
that the file does not exist and therefore must have been
inadvertently purged.
--------------------------------------------------------------------------------------
AC19089 ERROR-The file does not have a version number associated with it
Generated by: Administrator Utility
The version number could not be obtained from the file being
verified because the file has no user label and the version number
is kept in the user label of the file. Each Information Access
file that is to be verified has this version number inserted
before it is placed on the installation tape. The file must have
been replaced with an invalid file.
Restore the file from your installation tape and try the
verification test again. If the test still fails, call your HP
representative.
Table 1-0. (cont.)
--------------------------------------------------------------------------------------
AC19140 ERROR-FOPEN of file DHDPJOBS.PPCSAVE.HPOFFICE failed, FSERR number
Generated by: Administrator Utility
A file system error occurred during an attempt to open the file
DHDPJOBS.PPCSAVE.HPOFFICE that is built by the job
JINSTHDP.PPCUTIL.HPOFFICE as part of the installation process.
The file is used to log the major steps performed by the job and
is checked by the verification operation.
Check that the job JINSTHDP.PPCUTIL.HPOFFICE and all jobs it
streams executed successfully. Respond to the FSERR specified.
--------------------------------------------------------------------------------------
AC19141 ERROR-FREAD from file DHDPJOBS.PPCSAVE.HPOFFICE failed, FSERR
number
Generated by: Administrator Utility
A file system error occurred while during an attempt to read from
the file DHDPJOBS.PPCSAVE.HPOFFICE that is built by the job
JINSTHDP.PPCUTIL.HPOFFICE as part of the installation process.
The file is used to log the major steps performed by the job and
is checked by the verification operation.
Check that the job JINSTHDP.PPCUTIL.HPOFFICE and all jobs it
streams executed successfully. Respond to the FSERR specified.
--------------------------------------------------------------------------------------
AC19142 All the Information Access installation jobs finished successfully
Generated by: Administrator Utility
This is an informational message. The first time the verification
test is run after successful installation of Access Server, this
message appears in the DHDPVERS.PPCSAVE.HPOFFICE file. It
indicates that all the installation jobs completed without
aborting.
--------------------------------------------------------------------------------------
AC19143 ERROR-The installation job number aborted, see spoolfile for cause
Generated by: Administrator Utility
The first time the verification test is run after the installation
of Access Server, this message may appear in the
DHDPVERS.PPCSAVE.HPOFFICE file. It indicates that the given
installation did not complete successfully.
Find the job control listing spoolfile for the given job and
examine it.
Table 1-0. (cont.)
--------------------------------------------------------------------------------------
AC19144 ERROR-Information Access installation failed
Generated by: Administrator Utility
This message indicates that one or more installation jobs did not
complete successfully.
The names of the jobs that did not complete successfully can be
found in DHDPVERS.PPCSAVE.HPOFFICE. Find the job control listing
spoolfile for the given job and examine it.
MPE/iX 5.0 Documentation