HP 3000 Manuals

What You Will Need [ HP LaserRX/MPE Software Update Notice ] MPE/iX 5.0 Documentation


HP LaserRX/MPE Software Update Notice

What You Will Need 

The data collection component of the HP LaserRX/MPE software, called HP
Performance Collection Software or the SCOPE collector, must be installed
on each HP 3000 computer you want to monitor.  The collection software is
not provided on the flexible disks that contain the PC software (the
analysis component).

First-time buyers of HP LaserRX/MPE receive an MPE SUBSYS tape containing
the HP Performance Collection Software.

Existing customers who are monitoring MPE/iX systems and who want to use
the new sockets connection feature of HP LaserRX/MPE must update the
collection software on their HP 3000 systems.  You can get the latest
version of the collection software in one of the following ways:

   *   Request an MPE/iX SUBSYS tape, version 5.0, Express II release or
       later, containing the HP Performance Collection Software from your
       HP support representative.

   *   Request the latest version of software patch LRXHX04 for HP
       LaserRX/MPE from your HP support representative.  This patch works
       for MPE/iX version B.40.00 (4.0) and later.

HP 3000 Hardware Requirements 

The HP 3000 system (or systems) from which performance data will be
collected for analysis must be equipped with the following: 

   *   Either of the following:

          *   An RS-232 asynchronous interface (for basic serial
              connections)

              or 

          *   A LANIC and appropriate network interface (ThinMAU,
              EtherTwist, etc.)

   *   Approximately 60 MB of disk storage for HP LaserRX/MPE logfiles.

HP 3000 Software Requirements 

To be able to run HP LaserRX/MPE, your HP 3000 must have the following
software installed:

   *   Either of the following:

          *   MPE V G.2P.00 (Platform 2P) or later for MPE V systems.

              or 

          *   MPE/iX release B.40.00 (4.0) or later for MPE/iX systems.

   *   HP network services software (if you use this type of network
       connection when running the HP LaserRX/MPE software).

HP 3000 Configuration Requirements 

On MPE V systems, the following values must be configured:

   *   Set the MAX CODE SEGMENT SIZE to its maximum of 16384.

   *   Set the MAX # OF SEGMENTS/PROCESS to 16 (or more).

   *   Set the MAX STACK SIZE to its maximum of 31232.

   *   Set the MAX EXTRA DATA SEGMENT SIZE to its maximum of 32764.

   *   Set the MAX # OF EXTRA DATA SEGMENTS/PROCESS to 4 (or more).

   *   Set the PROCESS CONTROL BLOCK (PCB) table to 627 entries (or less)
       on MPE V releases prior to release 23.

See the MPE V System Manager/System Supervisor Reference Manual for
further information on changing these values.



MPE/iX 5.0 Documentation