What You Will Need [ HP Performance Collection Software User's Manual (for MPE Systems) ] MPE/iX 5.0 Documentation
HP Performance Collection Software User's Manual (for MPE Systems)
What You Will Need
This section describes the hardware and software requirements for the HP
3000 system.
Hardware Requirements
The HP 3000 system (or systems) from which you will collect performance
data for analysis must be equipped with the following:
* Either of the following, if the HP LaserRX/MPE analysis software
is used:
* An RS-232 asynchronous interface (for basic serial connections).
or
* A LANIC and ThinMAU interface (for Local Area Network
connections).
* Approximately 60 MB of disc storage for Performance Collection
Software log files.
Software Requirements
To be able to run Performance Collection Software, your HP 3000 must have
the following software installed:
* One of the following:
* MPE V G.03.02 (V-Delta-2 MIT) or later (for MPE V systems).
or
* MPE/iX release A.41.00 (2.1) or later (for MPE/iX systems).
* Local Area Network software, if you use this type of network
connection when running the HP LaserRX/MPE analysis software.
Configuration Requirements
On MPE V systems, the following values must be configured:
* Set the MAX CODE SEGMENT SIZE to its maximum of 16384.
* Set the MAX # OF SEGMENTS/PROCESS to 16 (or more).
* Set the MAX STACK SIZE to its maximum of 31232.
* Set the MAX EXTRA DATA SEGMENT SIZE to its maximum of 32764.
* Set the MAX # OF EXTRA DATA SEGMENTS/PROCESS to 4 (or more).
See the MPE V System Manager/System Supervisor Reference Manual for
further information on changing these values.
MPE/iX 5.0 Documentation