MAINTTIME
MAINTTIME hour [:minute]
where hour is a one- or two-digit number from 1 to 24, and minute is a
two-digit number from 00 to 59. Specify the time in a 24-hour-clock
format with midnight=00:00 and noon=12:00.
As the default, daily scheduled maintenance will not be performed.
The MAINTTIME directive sets the time for daily maintenance procedures.
If a valid time is specified, the following activities will be performed
by the SCOPE(XL) collector daily at that time:
* Global, Application, and Process log files are examined to
estimate if they might be filled within the next 24 hours. If so,
a log file roll back is performed immediately rather than waiting
until the next day. This ensures that log file roll back
operations occur at scheduled times rather than at random.
* Scratch disc files that remain after remote log file access are
purged. On MPE/iX, these files are named uniquely as HCLS
followed by four numbers, and on MPE V, as HCLST followed by three
numbers. Only files in the logon group for the SCOPE(XL)
collector are accessed, and only empty files are purged.
MPE/iX 5.0 Documentation