DAILYTIME
DAILYTIME hour [:minute]
where hour is a one- or two-digit number from 1 to 24, and minute is a
two-digit number from 00 to 59. Specify the time in a 24-hour-clock
format: midnight=00:00 and noon=12:00.
The default time for daily collections is
DAILYTIME 23:30
(The time, 23:30, is 11:30 PM.)
The DAILYTIME directive sets the time for the daily data collection.
Certain types of data, such as disc space, are only sampled and logged
once a day. On some systems such as MPE V, this sampling can use
significant amounts of system resources and should be scheduled for times
when it is likely that the system will be idle.
You can specify the time for the daily data collection in two formats:
* DAILYTIME 22 specifies data collection should occur at 22:00 hours
(10:00 PM).
Use this format to specify times on the hour.
* DAILYTIME 22:12 specifies data collection should occur 12 minutes
after 22:00 hours or 10:12 PM.
Use this format to specify times other than on the hour. Simply
add a colon and the minutes.