Ping/XL Error and Information Messages [ Installing and Managing HP ARPA File Transfer Protocol Network Manager's Guide ] MPE/iX 5.0 Documentation
Installing and Managing HP ARPA File Transfer Protocol Network Manager's Guide
Ping/XL Error and Information Messages
In addition to the normal reply message details and statistics, PING/XL
can display informational and/or error messages which are described
below.
---------------------------------------------------------------------------------------
MESSAGE Receive timeout occurred. Shutting Down...
CAUSE The PING/XL process has not received any response to its requests for
two minutes. So it shuts itself down, assuming that the local or the
remote side is inactive.
ACTION This could indicate that the remote node is unreachable. Also check
if the local node is congested or hung causing the local ICMP Server
not to respond. (The local ICMP Server interacts with PING/XL to
send ICMP Echo Requests to the remote, and passes incoming replies to
the right PING/XL process.)
---------------------------------------------------------------------------------------
MESSAGE Cannot contact local ICMP Server. Shutting down...
CAUSE PING/XL cannot contact the above mentioned local ICMP Server.
ACTION Check if the Transport is active. If not, start the transport.
---------------------------------------------------------------------------------------
MESSAGE Server not accepting requests, as it is busy. Please try later.
CAUSE Only 15 PING/XL processes can be active at any time. That is, only
15 users can run PING/XL at the same time. Additional users trying
to run PING/XL will get this error message.
ACTION Wait, and try later. One of the other PING/XL processes might have
completed, allowing you to run the program.
---------------------------------------------------------------------------------------
MESSAGE Cannot resolve path to remote. Path Error, Parm = # Parm_Value. Refer
PATH RESULT CODES table in NS 3000/XL Error Messages Manual.
CAUSE A suitable path out of the local node to reach the remote node could
not be found.
ACTION Look up the table mentioned in the message, under the Parm_Value
code, and take the action recommended therein.
---------------------------------------------------------------------------------------
MESSAGE Arithmetic trap Parm. Program Quitting.
CAUSE This is an internal error.
ACTION Submit an SR with the Parm value, a description of what you were
trying to do, and any other error messages printed on the terminal.
To submit an SR, see the NS3000/XL Operations and Maintenance Manual.
Internal Errors
The following messages are all internal errors, and should not happen
under normal circumstances. In each case, submit an SR (see the
NS3000/XL Operations and Maintenance Manual).
* Error opening $STDIN. Program quitting.
* Error opening $STDLIST. Program quitting.
* Cannot create port. Program quitting.
* Internal Error in server. Shutting Down...
* Buffer Error in server. Shutting Down...
MPE/iX 5.0 Documentation