X.25 Logging Location Codes [ NS3000/iX Error Messages Reference Manual ] MPE/iX 5.0 Documentation
NS3000/iX Error Messages Reference Manual
X.25 Logging Location Codes
X.25 logging falls under the transport subsystem (SUB0006). It logs 4
different classes of errors. They are:
Class 2 - Internal Errors. This usually means a bug somewhere.
Class 3 - Resource Errors. These should be recoverable, but a
configuration adjustment may be a good idea.
Class 4 - Nodal information. This is just information about Phobos being
started and stopped. Links going up and down etc.
Class 5 - Informative. Usually just a commentary on good things
happening. If problems are occurring it is good to examine these to
help.
In several of the CLAS0005 informative messages, the PARM contains the
Device ID, VC number, cause, and diagnostic. The Device ID is in the
first 4 bits. This number differentiates between different cards when
multiple cards per network ar used. If only one card is configured for
the network, the Device ID is 0. The VC number is in the next 12 bits,
the cause is in the third byte, and the diagnostic is in the fourth byte.
1-70 CLAS0002 Cause: X.25 tried to send a message, but the send_msg
call failed (PARM = status from send_msg)
Action: See "Submitting an SR" in appendix A of this
manual.
100 CLAS0002 Cause: A packet smaller than the minimum packet
length (4 bytes) was received from the DTC (PARM =
length of packet).
Action: See "Submitting an SR" in appendix A of this
manual.
101 CLAS0002 Cause: An unrecognized packet was received from the
DTC (PARM = ALCP packet type).
Action: See "Submitting an SR" in appendix A of this
manual.
102 CLAS0002 Cause: Internal Error. Map_X25_Update failed (PARM =
status from Map_X25_Update).
Action: See "Submitting an SR" in appendix A of this
manual.
103 CLAS0002 Cause: Internal Error. Map_X25_Update failed (PARM =
status from Map_X25_Update).
Action: See "Submitting an SR" in appendix A of this
manual.
104 CLAS0005 Cause: X.25 received an outbound data packet from IP,
but the connection is not in the correct state to send
the message. This can occur when a connection is
closing. If this happens consistently, it means that
the X.25 and TCP tables are inconsistent (PARM =
connection points).
Action: Issue a NETCONTROL STOP followed by a
NETCONTROL START to clear this condition. If this
happens frequently, see "Submitting an SR" in appendix
A of this manual.
105 CLAS0002 Cause: An ALCP packet was received with an incorrect
trailer byte. The trailer should be 1 or 3 (PARM =
trailer).
Action: See "Submitting an SR" in appendix A of this
manual.
106 CLAS0002 Cause: Internal Error. Netfc_delete_pool failed. A
resource was lost. If this happens frequently, the
transport will not be able to open new connections
(PARM = status from Netfc_delete_pool).
Action: If this happens frequently, see "Submitting
an SR" in appendix A of this manual.
107 CLAS0002 Cause: Internal Error. IPC sent zero bytes of data
to X.25 for transmission.
Action: See "Submitting an SR" in appendix A of this
manual.
108 CLAS0002 Cause: Internal Error. IPC sent zero bytes of data
to X.25 for transmission.
Action: See "Submitting an SR" in appendix A of this
manual.
109 CLAS0002 Cause: Internal Error. Netfc_delete_pool failed. A
resource was lost. If this happens frequently, the
transport will not be able to open new connections
(PARM = status from Netfc_delete_pool).
Action: See "Submitting an SR" in appendix A of this
manual.
110 CLAS0002 Cause: X.25 received an unexpected event for a
particular connection's state (PARM = state and
event).
Action: See "Submitting an SR" in appendix A of this
manual.
111 CLAS0002 Cause: X.25 received a message for an unknown
connection (PARM = connection points).
Action: See "Submitting an SR" in appendix A of this
manual.
112 CLAS0002 Cause: Internal Error. Map_Add_Rout failed (PARM =
status from Map_add_rout).
Action: See "Submitting an SR" in appendix A of this
manual.
113 CLAS0005 Cause: An incoming connection request was rejected
because the local facility does not have a Closed User
Group number configured, but the connection request
contains a Closed User Group number.
Action: Informative message. If you want the system
to accept connection requests from members of the
Closed User Group, modify the facility set to contain
the CUG number.
114 CLAS0002 Cause: Internal Error. Bmgr_Read_Buffer failed (PARM
= status from Bmgr_read_buffer).
Action: See "Submitting an SR" in appendix A of this
manual.
115 CLAS0002 Cause: Internal Error. Convert_dst failed (PARM =
status from Convert_dst).
Action: See "Submitting an SR" in appendix A of this
manual.
116 CLAS0002 Cause: Internal Error. Get_timer failed (PARM =
status from Get_timer).
Action: See "Submitting an SR" in appendix A of this
manual.
117 CLAS0002 Cause: Received an IPC port ID of zero in an
IPCCreate call.
Action: See "Submitting an SR" in appendix A of this
manual.
118 CLAS0002 Cause: A bad socket pointer was sent by IPC after an
IPShutdown intrinsic was called (PARM = socket
pointer).
Action: See "Submitting an SR" in appendix A of this
manual.
119 CLAS0002 Cause: Internal Error. Map_X25_Update failed (PARM =
status from Map_X25_update).
Action: See "Submitting an SR" in appendix A of this
manual.
125 CLAS0002 Cause: Internal Error. Convert_dst failed (PARM =
status from Convert_dst).
Action: See "Submitting an SR" in appendix A of this
manual.
126 CLAS0002 Cause: Internal Error. IPC sent zero bytes of data
to X.25 for transmission.
Action: See "Submitting an SR" in appendix A of this
manual.
127 CLAS0002 Cause: X.25 received an unexpected event for the
socket server (PARM = state and event).
Action: See "Submitting an SR" in appendix A of this
manual.
128 CLAS0005 Cause: An inactivity timer expired for the specified
VC number.
Action: None. This is an informative message.
129 CLAS0004 Cause: X.25 module has finished.
Action: None. This is an informative message.
130 CLAS0002 Cause: A failure occurred during a read from the
configuration buffer (PARM = status and length).
Action: See "Submitting an SR" in appendix A of this
manual.
131 CLAS0002 Cause: The configuration file contains more than the
allowed number of facility sets (PARM = number of
facility sets).
Action: See "Submitting an SR" in appendix A of this
manual.
132 CLAS0002 Cause: An error occurred while reading a facility set
from the configuration file (PARM = length).
Action: See "Submitting an SR" in appendix A of this
manual.
133 CLAS0002 Cause: The configuration file contains more than the
allowed number of SVC paths (PARM = number of SVC
paths).
Action: See "Submitting an SR" in appendix A of this
manual.
134 CLAS0002 Cause: An error occurred while reading an SVC path
from the configuration file (PARM = length).
Action: See "Submitting an SR" in appendix A of this
manual.
135 CLAS0002 Cause: Internal Error. Convert_dst failed (PARM =
status from Convert_dst).
Action: See "Submitting an SR" in appendix A of this
manual.
136 CLAS0002 Cause: Internal Error. Dict_Add failed (PARM =
status from Dist_Add).
Action: See "Submitting an SR" in appendix A of this
manual.
137 CLAS0004 Cause: Link brought down with open connections. This
is a result of either the user doing a NETCONTROL
DELLINK, or the link failed (PARM = Connections in use
on this link).
Action: See "Submitting an SR" in appendix A of this
manual.
138 CLAS0002 Cause: Internal Error. Map_Add_Entity failed (PARM =
status from Map_Add_Entity).
Action: See "Submitting an SR" in appendix A of this
manual.
139 CLAS0002 Cause: Could not create the Control buffer pool for
this network (PARM = status from Bmgr_create_pool).
Action: See "Submitting an SR" in appendix A of this
manual.
140 CLAS0002 Cause: Internal Error. Dict_Delete failed (PARM =
status from Dict_Delete).
Action: See "Submitting an SR" in appendix A of this
manual.
141 CLAS0004 Cause: Maximum number of link entries already in use.
Cannot add another link entry.
Action: See "Submitting an SR" in appendix A of this
manual.
142 CLAS0002 Cause: Internal Error. Map_Del_Entity failed (PARM =
Map_Del_Entity).
Action: See "Submitting an SR" in appendix A of this
manual.
143 CLAS0002 Cause: Internal Error. Bmgr_Delete_Pool failed (PARM
= Bmgr_delete_pool).
Action: See "Submitting an SR" in appendix A of this
manual..
144 CLAS0002 Cause: X.25 received an unexpected event for the
control server (PARM = state and event).
Action: See "Submitting an SR" in appendix A of this
manual.
145 CLAS0002 Cause: X.25 received an unknown type of Information
message from the Control Process (PARM = information
message type).
Action: See "Submitting an SR" in appendix A of this
manual.
146 CLAS0002 Cause: X.25 received an unknown type of Restart
message from the Control Process (PARM = restart
message type).
Action: See "Submitting an SR" in appendix A of this
manual.
147 CLAS0002 Cause: X.25 received an unknown type of transport
message (PARM = transport message function code).
Action: See "Submitting an SR" in appendix A of this
manual.
148 CLAS0002 Cause: X.25 received an unknown type of IPC Control
request message (PARM = IPC Control request type).
Action: See "Submitting an SR" in appendix A of this
manual.
149 CLAS0002 Cause: X.25 received an unknown message type from IPC
(PARM = IPC message function code).
Action: See "Submitting an SR" in appendix A of this
manual.
150 CLAS0002 Cause: X.25 received an unknown message format (PARM
= message format).
Action: See "Submitting an SR" in appendix A of this
manual.
151 CLAS0002 Cause: X.25 received an initialization message from
the Control Process when its port data area was non
zero (PARM = control server state).
Action: See "Submitting an SR" in appendix A of this
manual.
153 CLAS0003 Cause: An attempt to open a new socket has failed
because the socket table is full (PARM = number of
sockets in use).
Action: Close some of the sockets which are no longer
useful and try again.
154 CLAS0005 Cause: A socket was opened (PARM = socket's address).
Action: None. This is an informative message.
155 CLAS0005 Cause: A socket was closed (PARM = socket's address).
Action: None. This is an informative message.
156 CLAS0004 Cause: An operator issued a NETCONTROL STOP command,
but there are sockets or connections currently in use.
These sockets are aborted before X.25 terminates (PARM
= number of sockets and connections in use).
Action: None. This is an informative message.
157 CLAS0005 Cause: An outbound IPC connection was opened (PARM =
Device ID, VC number).
Action: None. This is an informative message.
158 CLAS0005 Cause: An inbound TCP/IP connection was opened (PARM
= Device ID, VC number).
Action: None. This is an informative message.
159 CLAS0005 Cause: An inbound IPC connection was opened (PARM =
Device ID, VC number).
Action: None. This is an informative message..
160 CLAS0005 Cause: A connection was closed (PARM = Device ID, VC
number).
Action: None. This is an informative message.
161 CLAS0003 Cause: A connection cannot be opened as X.25 has
reached its limit for the number of connections (PARM
= number of connections in use).
Action: Close the connections which are no longer
being used and try again.
162 CLAS0003 Cause: X.25 is out of outbound buffers.
Action: The transport will still work but at a
reduced speed and increased CPU overhead. You might
want to increase the number of outbound buffers
configured.
163 CLAS0005 Cause: An incoming connection request was rejected
because it has requested reverse charging, and this
facility set does not accept reverse charge calls
(PARM = Device ID, VC number, cause, diagnostic).
Action: None. This is an informative message. If
you want to accept reverse charge calls, modify the
facility set.
164 CLAS0005 Cause: An incoming connection request was rejected
because it requested packet size negotiation, and this
facility set does not negotiate packet size (PARM =
Device ID, VC number, cause, diagnostic).
Action: None. This is an informative message. If
you want to negotiate packet size, modify the facility
set.
165 CLAS0005 Cause: An incoming connection request was rejected
because it requested window size negotiation, and this
facility set does not negotiate window size (PARM =
Device ID, VC number, cause, diagnostic).
Action: None. This is an informative message. If
you want to negotiate window size, modify the facility
set.
166 CLAS0005 Cause: An incoming connection request was rejected
because it requested throughput class negotiation, and
this facility set does not negotiate throughout class
(PARM = Device ID, VC number, cause, diagnostic).
Action: None. This is an informative message. If
you want to negotiate throughput class, modify the
facility set.
167 CLAS0005 Cause: An incoming connection request was rejected
because the address of the calling node was not in the
SVC path table and the address key POOL was not
configured (PARM = Device ID, VC number, cause,
diagnostic).
Action: None. This is an informative message. If
you want to accept this call, either enter this node's
X.25 address in the SVC path screen, or enter "POOL"
as the address key.
168 CLAS0005 Cause: An incoming connection request was rejected
because the security flag in the SVC path table
specified that inbound calls from this address are not
allowed (PARM = Device ID, VC number, cause,
daignostic).
Action: None. This is an informative message. If
you want to accept this call, set the security flag to
IN for this the SVC path.
169 CLAS0005 Cause: An incoming connection request was rejected
because the facility set associated with this address
does not exist (PARM = Device ID, VC number, cause,
diagnostic).
Action: None. This is an informative message.
170 CLAS0005 Cause: An incoming connection request was rejected
because the Closed User Group number in the packet
does not match the number in the facility set (PARM =
Device ID, VC number, cause, diagnostic).
Action: None. This is an informative message. If
you want the system in the Closed User Group, modify
the facility set.
171 CLAS0005 Cause: An incoming connection request was rejected
because the TCP/IP protocol was requested but the call
packet contained the fast select with restriction
facility (PARM = Device ID, VC number, cause,
diagnostic).
Action: None. This is an informative message. If
you want to accept this call, modify the remote
machine so that fast select restriction is not set.
172 CLAS0005 Cause: An incoming connection request was rejected
because the IPC socket with the protocol relative
address specified in the call has not been created
(PARM = Device ID, VC number, cause, diagnostic).
Action: None. This is an informative message. Check
that the program with this socket address is running.
173 CLAS0005 Cause: An incoming connection request was rejected by
the IPC user or application program (PARM = Device ID,
VC number, cause, diagnostic).
Action: None. This is an informative message.
174 CLAS0003 Cause: An incoming connection request was rejected
because there are no outbound buffers available.
Action: Try again later. Or increase the number of
buffers configured and try again.
175 CLAS0005 Cause: An outgoing IPC connection request was
rejected because the path report did not contain an IP
address that is in the same IP network as this node.
Action: Check the IP addresses of the local and
remote nodes. The network portion of the IP addresses
should be the same.
176 CLAS0003 Cause: An AFCP connection could not be opened to the
DTC. The DTC card could be fully utilized by another
MPE/XL host (PARM = status from MCM).
Action: Try again later.
177 CLAS0005 Cause: An outgoing IPC connection request was
rejected. The rejection may have come from the local
DTC, the network, or the remote node (PARM = Device
ID, VC number, cause, diagnostic).
Action: Check the diagnostic code returned. Verify
that all components are operational.
178 CLAS0005 Cause: An outgoing TCP/IP connection request was
rejected. The rejection may have come from the local
DTC, the network, or the remote node (PARM = Device
ID, VC number, cause, diagnostic).
Action: Check the diagnostic code returned. Verify
that all components are operational.
179 CLAS0005 Cause: An outgoing connection request was rejected
because the AFCP connection was closed.
Action: Check that the DTC is operational. Try again
later.
180 CLAS0005 Cause: An incoming IPC connection request was
rejected by the DTC (PARM = Device ID, VC number,
cause, diagnostic).
Action: Check that the DTC is still operational.
181 CLAS0005 Cause: An incoming IPC connection request was
rejected by the local IPC user or application program
(PARM = Device ID, VC number, cause, diagnostic).
Action: None. This is an informative message.
182 CLAS0005 Cause: An outgoing connection request was rejected
because the security field in the SVC path table
specifies that outgoing calls to this address are not
allowed.
Action: If outgoing calls to this address are
desired, the security field of the SVC path must be
set to OU.
183 CLAS0005 Cause: An outgoing connection request was rejected
because the specified facility set for this address
key could not be found.
Action: Define a new facility set for this
configuration, or assign an existing facility set to
the configuration.
184 CLAS0005 Cause: An outgoing TCP/IP connection request was
rejected because the connection was requested over a
PVC.
Action: Modify the configuration to use an SVC.
185 CLAS0003 Cause: An outgoing TCP/IP connection request was
rejected because there are no outbound buffers
currently available.
Action: Try again later, or increase the number of
buffers configured.
186 CLAS0005 Cause: An outgoing IPC connection request was
rejected because the specified facility set does not
exist.
Action: Define a new facility set for this
configuration, or assign an existing facility set.
187 CLAS0005 Cause: An outgoing IPC connection request was
rejected because the specified Call User Data field is
too long.
Action: Either decrease the size of the call user
data field or use the fast select facility, or use the
"no address" flag.
188 CLAS0005 Cause: An outgoing IPC connection request was
rejected because the specified destination node does
not have an X.25 address in the configuration file.
Action: Make sure that the SVC path for the
destination node in the configuration file matches the
Network Directory. The address keys must be the same.
189 CLAS0003 Cause: An outgoing IPC connection request was
rejected because no outbound buffers are currently
available.
Action: Try again later, or increase the number of
outbound buffers configured.
190 CLAS0003 Cause: A connection cannot be opened because no free
semaphore resources are available to create an
expedited semaphore pool. Either the system is at its
limit of 1024 connections, or semaphores were steadily
lost and the supply is exhausted (PARM = status from
Netfc_create_pool).
Action: Try again later. If the maximum number of
VCs are not open, submit and SR. See "Submitting an
SR" in appendix A of this manual.
191 CLAS0003 Cause: A connection cannot be opened because no free
semaphore resources are available to create a regular
semaphore pool. Either the system is at its limit of
1024 connections, or semaphores were steadily lost and
the supply is exhausted (PARM = status from
Netfc_create_pool).
Action: Try again later.
192 CLAS0002 Cause: Internal Error. Netfc_Delete_Pool failed on
expedited semaphore pool (PARM = status from
Netfc_delete_pool).
Action: A resource was lost. If this happens
frequently, the transport will not be able to open new
connections. See "Submitting an SR" in Appendix of
this manual.
193 CLAS0002 Cause: Internal Error. Netfc_Delete_Pool failed on
regular semaphore pool (PARM = status from
Netfc_delete_pool).
Action: If this happens frequently, the transport
will not be able to open new connections. See
"Submitting an SR" in Appendix of this manual.
194 CLAS0002 Cause: Internal Error. Netfc_Create_Pool failed
right after a Netfc_Delete_Pool (PARM = status from
Netfc_create_pool).
Action: See "Submitting an SR" in appendix A of this
manual.
195 CLAS0004 Cause: The link for the X.25 network was started.
Action: None. This is an informative message.
197 CLAS0005 Cause: An N-Connect indication packet was received
(PARM = Device ID, VC number).
Action: None. This is an informative message.
198 CLAS0005 Cause: An N-Connect confirmation packet was received
(PARM = Device ID, VC number).
Action: None. This is an informative message.
199 CLAS0005 Cause: An N-Disconnect packet was received (PARM =
Device ID, VC number, cause, diagnostic).
Action: None. This is an informative message.
200 CLAS0005 Cause: An N-Disconnect packet was sent because an IP
connection's inactivity timer expired (PARM = Device
ID, VC number, cause, diagnostic).
Action: None. This is an informative message.
201 CLAS0005 Cause: An N-Disconnect packet was sent because an
incoming connection request was rejected (PARM =
Device ID, VC number, cause, diagnostic).
Action: None. This is an informative message.
202 CLAS0005 Cause: An N-Disconnect packet was sent because an IPC
user or application program called an IPCShutdown
intrinsic (PARM = Device ID, VC number, cause,
diagnostic).
Action: None. This is an informative message..
203 CLAS0005 Cause: An N-Disconnect packet was sent because an IPC
user or application rejected an incoming connection
request (PARM = Device ID, VC number, cause,
diagnostic).
Action: None. This is an informative message.
204 CLAS0005 Cause: An N-Disconnect packet was sent because an IPC
user or application has terminated with an incoming
connection request pending (PARM = Device ID, VC
number, cause, diagnostic).
Action: None. This is an informative message.
205 CLAS0005 Cause: An N-Disconnect packet was sent because an IPC
connection's inactivity timer expired (PARM = Device
ID, VC number, cause, diagnostic).
Action: None. This is an informative message.
206 CLAS0005 Cause: An N-Connect request packet was sent.
Action: None. This is an informative message.
207 CLAS0005 Cause: An N-Connect confirmation packet was sent
(PARM = Device ID, VC number).
Action: None. This is an informative message..
208 CLAS0005 Cause: An N-Connect confirmation packet was sent
(PARM = Device ID, VC number).
Action: None. This is an informative message.
209 CLAS0002 Cause: Internal Error. A Buffer could not be
obtained from the control buffer pool (PARM = status
from Bmgr_get_buffer).
Action: See "Submitting an SR" in appendix A of this
manual.
210 CLAS0002 Cause: Reading the configuration buffer failed on a
Netcontrol Update (PARM = status and length).
Action: See "Submitting an SR" in appendix A of this
manual.
211 CLAS0002 Cause: There are more facility sets in the
configuration file than allowed (PARM = number of
facility sets).
Action: See "Submitting an SR" in appendix A of this
manual.
212 CLAS0002 Cause: An error occurred while reading a facility set
from the configuration file (PARM = length).
Action: See "Submitting an SR" in appendix A of this
manual.
213 CLAS0002 Cause: Internal Error. An escape occurred inside
X.25 (PARM = escape code).
Action: See "Submitting an SR" in appendix A of this
manual.
214 CLAS0005 Cause: An N-Disconnect packet was sent because a
message arrived that was greater than 30 kilobytes
(PARM = Device ID, VC number, cause, diagnostic).
Action: Change the remote application to send less
than 30 kilobytes of data at a time.
215 CLAS0002 Cause: Internal error. Netfc_create_pool failed
right after a Netfc_delete_pool (PARM = status from
Netfc_create_pool).
Action: See "Submitting an SR" in appendix A of this
manual.
216 CLAS0002 Cause: Internal error. Netfc_delete_pool failed on
expedited semaphore pool (PARM = status from
Netfc_delete_pool).
Action: See "Submitting an SR" in appendix A of this
manual.
217 CLAS0002 Cause: Internal error. Netfc_delete_pool failed on
regular semaphore pool (PARM = status from
Netfc_delete_pool).
Action: See "Submitting an SR" in appendix A of this
manual.
218 CLAS0005 Cause: An incoming connection request was rejected
because it requests Fast Select and the facility does
not allow Fast Select (PARM = Device ID, VC number,
cause, diagnostic).
Action: None. This is an informative message. If
you want Fast Select, modify the facility set.
219 CLAS0005 Cause: An incoming connection request was rejected
because the local facility set has a Closed User Group
number configured, but the packet does not contain a
Closed User Group number (PARM = status from
map_get_device_info).
Action: None. This is an informative message. If
you want the remote system to be able to establish a
connection with this system, modify the remote
system's facility set to contain the Closed User Group
number.
221 CLAS0003 Cause: An inbound connection request has been
rejected because the device entry in Map has been
deleted. Occasionally, this can be a normal event
indicating that the link between the system and the
DTC went down just after a connection request was
received by the system (PARM = Status from
map_get_device_info).
Action: Verify that the link between the system and
the DTC is up: From the system, check for a non-zero
LDEV in the NETCONTROL STATUS;NI=<x25niname> display.
From OpenView DTC Manager, check the host entries at
the end of the X.25 level 3 status display. If the
link is up, try the connection again. If this message
is logged consistently, see "Submitting an SR" in
appendix A of this manual.
222 CLAS0003 Cause: An inbound connection request has been
rejected because the device state in Map is
disconnected. Occasionally, this can be a normal
event indicating that the link between the system and
the DTC went down just after a connection request was
received by the system.
Action: Verify that level 3 on the DTC\X.25 Network
Access card is up. From OpenView DTC Manager, check
the level 3 status display. If level 3 is up, try the
connection again. If this message is logged
consistently, see "Submitting an SR" in appendix A of
this manual.
223 CLAS0002 Cause: Internal Error. Map_X25_Update failed on
inbound connection establishment (PARM = Status from
Map_X25_Update).
Action: See "Submitting an SR" in appendix A of this
manual.
224 CLAS0005 Cause: Map_find_best_device failed on outbound level
3 connection establishment Occasionally, this can be a
normal event indicating that the link between the
system and the DTC went down just after a connection
request was received by the system. (PARM = Status
from Map_find_best_device).
Action: Verify that the link between the system and
the DTC is up: From the system, check for a non-zero
LDEV in the NETCONTROL STATUS;NI=<x25niname> display.
From OpenView DTC Manager, check the host entries at
the end of the X.25 level 3 status display. If the
link is up, try the connection again. If this message
is logged consistently, see "Submitting an SR" in
appendix A of this manual.
225 CLAS0002 Cause: X.25 tried to send a message to X25STAT but
the call failed. (PARM = status from send_msg).
Action: Try running X25STAT again. If this logging
message is logged consistently, see "Submitting an SR"
in appendix A of this manual.
226 CLAS0004 Cause: Link brought down with open connections. This
is a result of a Netcontrol Stop on this X.25 network.
(PARM = Connections in use on this link).
Action: None. This is an informative message.
228 CLAS0002 Cause: Internal Error. Link_ptr is nil. (PARM= link
id)
Action: See "Submitting an SR" in Appendix A of this
manual.
229 CLAS0002 Cause: Internal Error. BMGR_DELETE_POOL call failed
while start sequence was aborting. (PARM= status from
call)
Action: See "Submitting an SR" in Appendix A of this
manual.
230 CLAS0002 Cause: Internal Error. Unknown link for disconnect
reply. (PARM= link id)
Action: See "Submitting an SR" in Appendix A of this
manual.
231 CLAS0002 Cause: Internal Error. Unknown link while
DELLINKing. (PARM= link id)
Action: See "Submitting an SR" in Appendix A of this
manual.
232 CLAS0002 Cause: Internal Error. Unknown link. (PARM= link
id)
Action: See "Submitting an SR" in Appendix A of this
manual.
MPE/iX 5.0 Documentation