Pre-Configuration Software Check [ HP3000/iX Network Planning and Configuration Guide ] MPE/iX 5.0 Documentation
HP3000/iX Network Planning and Configuration Guide
Pre-Configuration Software Check
Once you have verified that your hardware has been correctly installed,
verify that the appropriate software is installed by performing the
following steps:
1. Ensure that the Datacommunications and Terminal Subsystem (DTS)
has been configured. If DTS has not been configured, refer to
Configuring Systems for Terminals, Printers, and Other Serial
Devices and configure the DTS before proceeding.
2. Check that the data communications software has been installed
properly by running the NMMAINT program (NMMAINT.PUB.SYS), which
is supplied as part of the node management services. NMMAINT will
tell you if any software modules are missing or invalid. See the
Using the Node Management Services (NMS) Utilities manual for a
discussion of the NMMAINT program.
3. Whenever you receive a new version of the node management services
(NMS) software (which includes NMMGR), and you have earlier
versions of NMS, you first have to run a conversion program. The
conversion program, called NMMGRVER (NMMGRVER.PUB.SYS), ensures
that configuration files created with an earlier version of NMMGR
are converted to the latest format.
MPE/iX 5.0 Documentation