HP 3000 Manuals

Authorizations [ ALLBASE/NET User's Guide ] MPE/iX 5.0 Documentation


ALLBASE/NET User's Guide

Authorizations 

If an application program uses a CONNECT command to start a DBE session,
the owner of the module must have CONNECT authority and RUN or module
OWNER authority to run the program.  The runtime CONNECT and RUN
authorities are based on the user's server login.  Additionally, the
module owner must have permission to access all objects acted upon by the
program.  This usually means one or more of the table or view authorities
must be granted to the module owner.  There may be other authorities
needed as well.

The module owner is defined at preprocess time by the -o option of the
preprocess command or, by default, the client's login.  Refer to "Client
and Server Login Names" under "Cross-System Connectivity" in the "Getting
Started" chapter. 



MPE/iX 5.0 Documentation