HP 3000 Manuals

ENDLOG [ MPE/iX Quick Reference Guide ] MPE/iX 5.0 Documentation


MPE/iX Quick Reference Guide

ENDLOG 

NM and CM callable.
Posts a record to the logging file marking the end of a logical
transaction.  When the record is posted, ENDLOG flushes the user logging
memory buffer to ensure that the record gets to the logging file.  User
logging (LG) or system supervisor (OP) capability is required.

             I32  U16A  I16   I16    I16
     ENDLOG(index,data,length,mode,logstatus);