Holding and Saving Configuration Changes
Using the system logging and user logging commands described in the
following sections changes the LOG configuration specified in the SYSGEN
command line or global BASEGROUP command. These changes are temporary
and are easily lost if not properly saved.
Saving configuration changes is a two-step procedure. After you alter a
configuration, you must, first, hold the changes before exiting the
configurator. Second, use the global module KEEP command to save the
changes.
To hold changes, enter the HOLD command at the LOG configurator prompt:
log>HOLD
You can work in a SYSGEN configurator, hold the changes, and continue
working in other SYSGEN configurators before saving the changes.
To save the changes, hold all desired changes, exit to SYSGEN's global
module, and issue the KEEP command:
sysgen>KEEP newgroupname
Refer to Chapter 4 for additional information on using the KEEP
command.